1-Phase Current Control Relays
1-phase current control relays with integrated current transformer - RM17JC
[/vc_column_text][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="2/3" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]The control relay RM17JC00MW is designed to monitor ∿ currents[/vc_column_text][divider line_type="No Line"][vc_column_text]These control relays allow:- Integrated current transformer
- Measurement range 2…20 A
- Choice of action on the output relay
- Clip-on mounting on a ⍽ rail
Applications
[/vc_column_text][divider line_type="No Line"][vc_column_text]- Load state control of motors and generators
- Control of current drawn by a 3-phase motor
- Monitoring of heating or lighting circuits
- Control of pump draining (undercurrent)
- Control of overtorque (crushers)
- Monitoring of electromagnetic brakes or clutches
Description
1. Overcurrent setting potentiometer 2. Spring for clip-on mounting on 35 mm/1.38 in. ⍽ rail[/vc_column_text][/vc_column][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/2" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][image_with_animation image_url="11199" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/1" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]Operating Principles
[/vc_column_text][vc_column_text]RM17JC00MW[/vc_column_text][divider line_type="No Line"][vc_row_inner column_margin="default" text_align="left"][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="2/3" column_border_width="none" column_border_style="solid"][vc_column_text]Control relay RM17JC00MW is:- equipped with an integrated current transformer
- fault signaling is by LED
- Relay RM17JC00MW controls overcurrent.
- The relay closes when the current exceeds the threshold setting on the front panel and opens when it drops below the threshold minus the hysteresis.
- When terminal Y1 is linked to A1 (+), the output is reversed. The relay opens when the current exceeds the threshold setting on the front panel and closes again when it drops below the hysteresis value.
1-phase current control relays - RM22JA and RM35JA
[/vc_column_text][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="2/3" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][vc_column_text]RM22JA and RM35JA[/vc_column_text][divider line_type="No Line"][vc_column_text]These control relays enable:- Automatic ⎓ or ∿ recognition
- Selection between overcurrent and undercurrent
- Measurement as a true rms value
- Selectable memory function
- Clip-on mounting on a ⍽ rail
- Dial pointer LED indicator for relay power ON status
- Relay output status LED
- A sealable cover to help protect the settings
- A control status indicator LED
Applications
[/vc_column_text][divider line_type="No Line"][vc_column_text]- Excitation control of DC machines
- Load state control of motors and generators
- Control of current drawn by a 3-phase motor
- Monitoring of heating or lighting circuits
- Control of pump draining (undercurrent)
- Control of overtorque (crushers)
- Monitoring of electromagnetic brakes or clutches
Description
[/vc_column_text][divider line_type="No Line"][vc_row_inner column_margin="default" text_align="left"][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/4" column_border_width="none" column_border_style="solid"][image_with_animation image_url="11194" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][image_with_animation image_url="11192" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][/vc_column_inner][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/4" column_border_width="none" column_border_style="solid"][image_with_animation image_url="11193" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][image_with_animation image_url="11191" alignment="" animation="Fade In" border_radius="none" box_shadow="none" max_width="100%"][/vc_column_inner][vc_column_inner column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="2/4" column_border_width="none" column_border_style="solid"][vc_column_text]1. Configuration: selection of operating mode e <I (undercurrent), >I (overcurrent), >I> (overcurrent and undercurrent), MEMORY - NO MEMORY (with or without memory) 2. Current threshold setting potentiometer I% 3a. Hysteresis adjustment potentiometer Hys 3b. Hysteresis/overcurrent and undercurrent window mode adjustment potentiometer Hys/>I> 4. Time delay adjustment potentiometer Tt 5. Diagnostic button 6. Overcurrent setting potentiometer >I[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/1" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][nectar_animated_title heading_tag="h2" style="color-strip-reveal" color="Accent-Color" text="Enquire Now"][gravityform id="7" title="false" description="false" ajax="false"][/vc_column][/vc_row][vc_row type="in_container" full_screen_row_position="middle" scene_position="center" text_color="dark" text_align="left" overlay_strength="0.3" shape_divider_position="bottom"][vc_column column_padding="no-extra-padding" column_padding_position="all" background_color_opacity="1" background_hover_color_opacity="1" column_shadow="none" column_border_radius="none" width="1/1" tablet_text_alignment="default" phone_text_alignment="default" column_border_width="none" column_border_style="solid"][nectar_animated_title heading_tag="h2" style="color-strip-reveal" color="Accent-Color" text="Discover More "][recent_posts style="default" category="schneider" columns="4" order="DESC" orderby="date" posts_per_page="4" post_offset="2"][/vc_column][/vc_row]With integrated current transformer – RM17JC
The control relay RM17JC00MW is designed to monitor ∿ currents
These control relays allow:
- Integrated current transformer
- Measurement range 2…20 A
- Choice of action on the output relay
- Clip-on mounting on a ⍽ rail
They feature a control status indicator LED.


Applications
- Load state control of motors and generators
- Control of current drawn by a 3-phase motor
- Monitoring of heating or lighting circuits
- Control of pump draining (undercurrent)
- Control of overtorque (crushers)
- Monitoring of electromagnetic brakes or clutches
Description
The control relay RM17JC00MW is designed to monitor ∿ currents
These control relays allow:
- Integrated current transformer
- Measurement range 2…20 A
- Choice of action on the output relay
- Clip-on mounting on a ⍽ rail
They feature a control status indicator LED.
1. Overcurrent setting potentiometer
2. Spring for clip-on mounting on 35 mm/1.38 in. ⍽ rail


Operating Principles for RM17JC00MW
Control relay RM17JC00MW is:
- equipped with an integrated current transformer
- fault signaling is by LED
An adjustable time delay on threshold crossing, provides immunity to transients, and helps prevent spurious triggering of the output relay


Overcurrent detection
- Relay RM17JC00MW controls overcurrent.
- The relay closes when the current exceeds the threshold setting on the front panel and opens when it drops below the threshold minus the hysteresis.
- When terminal Y1 is linked to A1 (+), the output is reversed. The relay opens when the current exceeds the threshold setting on the front panel and closes again when it drops below the hysteresis value.


1-phase current control relays – RM22JA and RM35JA
RM22JA and RM35JA
These control relays enable:
- Automatic ⎓ or ∿ recognition
- Selection between overcurrent and undercurrent
- Measurement as a true rms value
- Selectable memory function
- Clip-on mounting on a ⍽ rail
They feature:
- Dial pointer LED indicator for relay power ON status
- Relay output status LED
- A sealable cover to help protect the settings
- A control status indicator LED




Applications
- Excitation control of DC machines
- Load state control of motors and generators
- Control of current drawn by a 3-phase motor
- Monitoring of heating or lighting circuits
- Control of pump draining (undercurrent)
- Control of overtorque (crushers)
- Monitoring of electromagnetic brakes or clutches
Description








1. Configuration: selection of operating mode e <I (undercurrent), >I (overcurrent), >I> (overcurrent and undercurrent), MEMORY – NO MEMORY (with or without memory)
2. Current threshold setting potentiometer I%
3a. Hysteresis adjustment potentiometer Hys
3b. Hysteresis/overcurrent and undercurrent window mode adjustment potentiometer Hys/>I>
4. Time delay adjustment potentiometer Tt
5. Diagnostic button
6. Overcurrent setting potentiometer >I
Share this article on social media