XPSVNE1142P - Module XPSVN - Zero Speed Detection - 24 V DC for Motor Power Supply <= 60 Hz.
Schneider
SKU
SE_XPSVNE1142P
Model
XPSVNE1142P
SGD $1,464.36 All prices inclusive of GST
Short description of XPSVNE1142P
XPSVNE1142P. Safety Modules
Country of Origin
Indonesia
range of product : Preventa Safety automation
-  product or component type : Preventa safety module
-  safety module name : XPSVNE
-  safety module application : For zero speed detection
-  function of module : Monitoring 3-phase motor with star
- delta startingMonitoring 3-phase motor with variable number of poles and star
- delta startingMonitoring 3-phase motor + variable speed driveMonitoring 3-phase motorMonitoring XPS AKMonitoring star
- delta motor starter and guard switch type XCS EMonitoring dc motor
-  safety level : Can reach PL d/category 3 conforming to EN/ISO 13849-1Can reach SILCL 2 conforming to EN/IEC 62061
-  safety reliability data : MTTFd = 124.1 years conforming to EN/ISO 13849-1DC > 99 % conforming to EN/ISO 13849-1PFHd = 9.26E
- 9 1/h conforming to EN/IEC 62061
-  product certifications : CSAULTÜV
-  [Us] rated supply voltage : 24 V DC-15...10 %
-  output type : Relay, 1 NO + 1 NC circuit(s), volt
- free
-  number of additional circuits : 2 solid state outputs
-  product or component type : Preventa safety module
-  safety module name : XPSVNE
-  safety module application : For zero speed detection
-  function of module : Monitoring 3-phase motor with star
- delta startingMonitoring 3-phase motor with variable number of poles and star
- delta startingMonitoring 3-phase motor + variable speed driveMonitoring 3-phase motorMonitoring XPS AKMonitoring star
- delta motor starter and guard switch type XCS EMonitoring dc motor
-  safety level : Can reach PL d/category 3 conforming to EN/ISO 13849-1Can reach SILCL 2 conforming to EN/IEC 62061
-  safety reliability data : MTTFd = 124.1 years conforming to EN/ISO 13849-1DC > 99 % conforming to EN/ISO 13849-1PFHd = 9.26E
- 9 1/h conforming to EN/IEC 62061
-  product certifications : CSAULTÜV
-  [Us] rated supply voltage : 24 V DC-15...10 %
-  output type : Relay, 1 NO + 1 NC circuit(s), volt
- free
-  number of additional circuits : 2 solid state outputs
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24 V DC - 15...10 % |
Breaking Capacity | 1.2 A at 24 V (DC-13) time constant: 50 ms for NC relay output circuit 1.5 A at 24 V (DC-13) time constant: 50 ms for NO relay output circuit 10 mA at 48 V for solid state output circuit 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output 20 mA at 24 V for solid state output circuit |
Continuous Power | can reach PL d/category 3 conforming to EN/ISO 13849-1 can reach SILCL 2 conforming to EN/IEC 62061 |
Product Or Component Type | Preventa safety module |
Range Of Product | Preventa Safety automation |
Rated Power In W | 500 Vrms |
Function Of Module | monitoring 3-phase motor monitoring 3-phase motor + variable speed drive monitoring 3-phase motor with star-delta starting monitoring 3-phase motor with variable number of poles and star-delta starting monitoring dc motor monitoring star-delta motor starter and guard switch type XCS E monitoring XPS AK |
Mounting Support | 35 mm symmetrical DIN rail |
Number Of Additional Circuits | 2 solid state outputs |
Range Name | Preventa XPS |
Safety Module Application | for zero speed detection |
Safety Module Name | XPSVNE |
COMPLEMENTARY | |
Input Voltage | 500 Vrms |
Interlocked Device | 1.2 A at 24 V (DC-13) time constant: 50 ms for NC relay output circuit 1.5 A at 24 V (DC-13) time constant: 50 ms for NO relay output circuit 10 mA at 48 V for solid state output circuit 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output 20 mA at 24 V for solid state output circuit |
Product Name | relay, 1 NO + 1 NC circuit(s), volt-free |
Associated Fuse Rating | 4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
Connections - Terminals | captive screw clamp terminals, removable terminal block flexible cable: 0.2...1.5 mm² without cable end, 2 wires captive screw clamp terminals, removable terminal block flexible cable: 0.2...2.5 mm² without cable end, 1 wire captive screw clamp terminals, removable terminal block flexible cable: 0.25...1 mm² with cable end, without bezel, 2 wires captive screw clamp terminals, removable terminal block flexible cable: 0.25...2.5 mm² with cable end, with bezel, 1 wire captive screw clamp terminals, removable terminal block flexible cable: 0.25...2.5 mm² with cable end, without bezel, 1 wire captive screw clamp terminals, removable terminal block flexible cable: 0.5...1.5 mm² with cable end, with double bezel, 2 wires captive screw clamp terminals, removable terminal block solid cable: 0.2...1 mm² without cable end, 2 wires captive screw clamp terminals, removable terminal block solid cable: 0.2...2.5 mm² without cable end, 1 wire |
Depth | 114 mm |
Height | 99 mm |
Input Detection Threshold | 0.01...0.1 V |
Local Signalling | 4 LEDs |
Minimum Output Current | 10 mA for relay output |
Minimum Output Voltage | 17 V for relay output |
Net Weight | 0.5 kg |
Output Type | relay, 1 NO + 1 NC circuit(s), volt-free |
Power Consumption In W | 3.5 W |
Product Destination | for motor power supply <= 60 Hz |
Safety Reliability Data | DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 124.1 years conforming to EN/ISO 13849-1 PFHd = 9.26E-9 1/h conforming to EN/IEC 62061 |
Width | 45 mm |
[Ith] Conventional Free Air Thermal Current | 2.5 A for relay output |
[Uimp] Rated Impulse Withstand Voltage | 4 kV overvoltage category III conforming to DIN VDE 0110 parts 1 and 2 4 kV overvoltage category III conforming to IEC 60947-5-1 |
[Ui] Rated Insulation Voltage | 300 V (pollution degree 2) conforming to DIN VDE 0110 parts 1 and 2 300 V (pollution degree 2) conforming to IEC 60947-5-1 |
ENVIRONMENT | |
Safety Level | can reach PL d/category 3 conforming to EN/ISO 13849-1 can reach SILCL 2 conforming to EN/IEC 62061 |
Ambient Air Temperature For Operation | -10-55 °C |
Ambient Air Temperature For Storage | -25-85 °C |
IP Degree Of Protection | IP20 (terminals) conforming to EN/IEC 60529 IP40 (enclosure) conforming to EN/IEC 60529 |
Product Certifications | CSA TÜV UL |
Standards | EN/IEC 60204-1 EN/IEC 60947-5-1 |
OTHER | |
Poles Description | Preventa safety module |
[Us] Rated Supply Voltage | 24 V DC - 15...10 % |