Module XPS-MP - 2 Independent Functions - 24 V DC.

Schneider
SKU
SE_XPSMP11123P
Model
XPSMP11123P

Obsolete

Short description of XPSMP11123P

Safety controller.
Obsolete
*All information are subjected to changes without prior notice.
range of product : Preventa Safety automation
-  product or component type : Safety controller with pre-defined function
-  safety module name : XPSMP
-  safety module application : 2 independent functions
-  safety use category : Category 4 maximum conforming to EN/IEC 60954-1
-  type of start : Automatic or unmonitored (configuration 1)Automatic or unmonitored (configuration 10)Automatic or unmonitored (configuration 11)Automatic or unmonitored (configuration 14)Automatic or unmonitored (configuration 3)Automatic or unmonitored (configuration 5)Automatic or unmonitored (configuration 7)Monitored (configuration 12)Monitored (configuration 13)Monitored (configuration 15)Monitored (configuration 2)Monitored (configuration 4)Monitored (configuration 6)Monitored (configuration 8)Monitored (configuration 9)
-  checks : Configuration (configuration 10)Configuration (configuration 13)Configuration (configuration 3)Configuration (configuration 4)Configuration (configuration 5)Configuration (configuration 6)Configuration (configuration 9)
-  standards : DIN V VDE 801 + A1EN/IEC 60204-1EN/IEC 60947-1 + A11EN/IEC 60947-5-1
-  product certifications : ULBIACSA
-  [Us] rated supply voltage : 24 V DC
-  20...20 %
-  connections
-  terminals : Captive screw clamp terminals, removable terminal block solid cable :  0.2...1 mm² without cable end, 2 wiresCaptive screw clamp terminals, removable terminal block flexible cable :  0.2...1.5 mm² without cable end, 2 wiresCaptive screw clamp terminals, removable terminal block flexible cable :  0.2...2.5 mm² without cable end, 1 wireCaptive screw clamp terminals, removable terminal block solid cable :  0.2...2.5 mm² without cable end, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable :  0.25...1 mm² with cable end, without bezel, 2 wiresCaptive screw clamp terminals, removable terminal block flexible cable :  0.25...2.5 mm² with cable end, with bezel, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable :  0.25...2.5 mm² with cable end, without bezel, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable :  0.5...1.5 mm² with cable end, with double bezel, 2 wires
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SIL 3 conforming to EN/IEC 62061
MAIN SPECIFICATIONS
Analogue Input Number24 V DC - 20...20 %
Breaking Capacity1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
20 mA at 24 V for static output circuit
Continuous Powercan reach PL e/category 4 conforming to EN/ISO 13849-1
can reach SIL 3 conforming to EN/IEC 62061
Light Block Colorcategory 4 maximum conforming to EN/IEC 60954-1
Number Of Safety Circuits3 NO relays per function (6 NO total), volt-free
Product Or Component Typesafety controller with pre-defined function
Range Of ProductPreventa Safety automation
[Uc] Control Circuit Voltage24 V
Function Of Moduleconfiguration 0: functions disabled (factory setting)
configuration 1: emergency stop monitoring 1-channel wiring, category 2
configuration 10: enabling grip switch monitoring (3-position switch), category 4
configuration 11: sensing mat and edges monitoring, category 3
configuration 12: sensing mat and edges monitoring, category 3
configuration 13: relay output safety light curtain monitoring, category 4
configuration 14: coded magnetic switch monitoring, category 4
configuration 15: coded magnetic switch monitoring, category 4
configuration 2: emergency stop monitoring 1-channel wiring, category 2
configuration 3: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
configuration 4: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
configuration 5: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
configuration 6: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
configuration 7: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
configuration 8: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4
configuration 9: guard monitoring for injection presses and blowing machines, category 4
Mounting Support35 mm symmetrical DIN rail
Number Of Additional Circuits3 solid state outputs
Range NamePreventa XPS MP, XPS MC, XPS MCM
Safety Module Application2 independent functions
Safety Module NameXPSMP
Type Of Startautomatic or unmonitored (configuration 1)
automatic or unmonitored (configuration 10)
automatic or unmonitored (configuration 11)
automatic or unmonitored (configuration 14)
automatic or unmonitored (configuration 3)
automatic or unmonitored (configuration 5)
automatic or unmonitored (configuration 7)
monitored (configuration 12)
monitored (configuration 13)
monitored (configuration 15)
monitored (configuration 2)
monitored (configuration 4)
monitored (configuration 6)
monitored (configuration 8)
monitored (configuration 9)
COMPLEMENTARY
Interlocked Device1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
20 mA at 24 V for static output circuit
Safety Use Categorycategory 4 maximum conforming to EN/IEC 60954-1
Associated Fuse Rating4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Checksconfiguration (configuration 10)
configuration (configuration 13)
configuration (configuration 3)
configuration (configuration 4)
configuration (configuration 5)
configuration (configuration 6)
configuration (configuration 9)
Connections - Terminalscaptive screw clamp terminals, removable terminal block flexible cable: 0.2...1.5 mm² without cable end, 2 wires
captive screw clamp terminals, removable terminal block flexible cable: 0.2...2.5 mm² without cable end, 1 wire
captive screw clamp terminals, removable terminal block flexible cable: 0.25...1 mm² with cable end, without bezel, 2 wires
captive screw clamp terminals, removable terminal block flexible cable: 0.25...2.5 mm² with cable end, with bezel, 1 wire
captive screw clamp terminals, removable terminal block flexible cable: 0.25...2.5 mm² with cable end, without bezel, 1 wire
captive screw clamp terminals, removable terminal block flexible cable: 0.5...1.5 mm² with cable end, with double bezel, 2 wires
captive screw clamp terminals, removable terminal block solid cable: 0.2...1 mm² without cable end, 2 wires
captive screw clamp terminals, removable terminal block solid cable: 0.2...2.5 mm² without cable end, 1 wire
Depth114 mm
Height99 mm
Input Protection Typeinternal, electronic
Local Signalling12 LEDs
Maximum Line Resistance100 Ohm <2000 m
Maximum Response Time On Input Open30 ms
Minimum Output Current10 mA for relay output
Minimum Output Voltage17 V for relay output
Net Weight0.32 kg
Output Thermal Current2 A for 1 output and 4 A for the other 2 outputs for relay
3.3 A for all 3 outputs relay simultaneously
6 A for 1 output and 2 A for the other 2 outputs for relay
Power Consumption In W5 W
Synchronisation Time Between Inputs0.5 s (configuration 13)
1.5 s (configuration 14)
1.5 s (configuration 15)
1.5 s (configuration 5)
1.5 s (configuration 6)
1.5 s (configuration 9)
unlimited (configuration 3)
unlimited (configuration 4)
unlimited (configuration 7)
unlimited (configuration 8)
Width45 mm
[Ith] Conventional Free Air Thermal Current20 A
[Uimp] Rated Impulse Withstand Voltage4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
[Ui] Rated Insulation Voltage300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
ENVIRONMENT
Safety Levelcan reach PL e/category 4 conforming to EN/ISO 13849-1
can reach SIL 3 conforming to EN/IEC 62061
Type Of Output Stage3 NO relays per function (6 NO total), volt-free
Ambient Air Temperature For Operation-10-55 °C
Ambient Air Temperature For Storage-25-85 °C
IP Degree Of ProtectionIP20 (terminals)
IP40 (enclosure)
Product CertificationsBIA
CSA
UL
StandardsDIN V VDE 801 + A1
EN/IEC 60204-1
EN/IEC 60947-1 + A11
EN/IEC 60947-5-1
OTHER
Poles Descriptionsafety controller with pre-defined function
[Us] Rated Supply Voltage24 V DC - 20...20 %