XPSMP11123P - Module XPS-MP - 2 Independent Functions - 24 V DC.
Schneider
SKU
SE_XPSMP11123P
Model
XPSMP11123P
Obsolete
Short description of XPSMP11123P
XPSMP11123P. Safety controller.
Obsolete
range of product : Preventa Safety automation
-  product or component type : Safety controller with pre-defined function
-  safety module name : XPSMP
-  safety module application : 2 independent functions
-  safety use category : Category 4 maximum conforming to EN/IEC 60954-1
-  type of start : Automatic or unmonitored (configuration 1)Automatic or unmonitored (configuration 10)Automatic or unmonitored (configuration 11)Automatic or unmonitored (configuration 14)Automatic or unmonitored (configuration 3)Automatic or unmonitored (configuration 5)Automatic or unmonitored (configuration 7)Monitored (configuration 12)Monitored (configuration 13)Monitored (configuration 15)Monitored (configuration 2)Monitored (configuration 4)Monitored (configuration 6)Monitored (configuration 8)Monitored (configuration 9)
-  checks : Configuration (configuration 10)Configuration (configuration 13)Configuration (configuration 3)Configuration (configuration 4)Configuration (configuration 5)Configuration (configuration 6)Configuration (configuration 9)
-  standards : DIN V VDE 801 + A1EN/IEC 60204-1EN/IEC 60947-1 + A11EN/IEC 60947-5-1
-  product certifications : ULBIACSA
-  [Us] rated supply voltage : 24 V DC
-  20...20 %
-  connections
-  terminals : Captive screw clamp terminals, removable terminal block solid cable :  0.2...1 mm² without cable end, 2 wiresCaptive screw clamp terminals, removable terminal block flexible cable :  0.2...1.5 mm² without cable end, 2 wiresCaptive screw clamp terminals, removable terminal block flexible cable :  0.2...2.5 mm² without cable end, 1 wireCaptive screw clamp terminals, removable terminal block solid cable :  0.2...2.5 mm² without cable end, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable :  0.25...1 mm² with cable end, without bezel, 2 wiresCaptive screw clamp terminals, removable terminal block flexible cable :  0.25...2.5 mm² with cable end, with bezel, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable :  0.25...2.5 mm² with cable end, without bezel, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable :  0.5...1.5 mm² with cable end, with double bezel, 2 wires
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SIL 3 conforming to EN/IEC 62061
-  product or component type : Safety controller with pre-defined function
-  safety module name : XPSMP
-  safety module application : 2 independent functions
-  safety use category : Category 4 maximum conforming to EN/IEC 60954-1
-  type of start : Automatic or unmonitored (configuration 1)Automatic or unmonitored (configuration 10)Automatic or unmonitored (configuration 11)Automatic or unmonitored (configuration 14)Automatic or unmonitored (configuration 3)Automatic or unmonitored (configuration 5)Automatic or unmonitored (configuration 7)Monitored (configuration 12)Monitored (configuration 13)Monitored (configuration 15)Monitored (configuration 2)Monitored (configuration 4)Monitored (configuration 6)Monitored (configuration 8)Monitored (configuration 9)
-  checks : Configuration (configuration 10)Configuration (configuration 13)Configuration (configuration 3)Configuration (configuration 4)Configuration (configuration 5)Configuration (configuration 6)Configuration (configuration 9)
-  standards : DIN V VDE 801 + A1EN/IEC 60204-1EN/IEC 60947-1 + A11EN/IEC 60947-5-1
-  product certifications : ULBIACSA
-  [Us] rated supply voltage : 24 V DC
-  20...20 %
-  connections
-  terminals : Captive screw clamp terminals, removable terminal block solid cable :  0.2...1 mm² without cable end, 2 wiresCaptive screw clamp terminals, removable terminal block flexible cable :  0.2...1.5 mm² without cable end, 2 wiresCaptive screw clamp terminals, removable terminal block flexible cable :  0.2...2.5 mm² without cable end, 1 wireCaptive screw clamp terminals, removable terminal block solid cable :  0.2...2.5 mm² without cable end, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable :  0.25...1 mm² with cable end, without bezel, 2 wiresCaptive screw clamp terminals, removable terminal block flexible cable :  0.25...2.5 mm² with cable end, with bezel, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable :  0.25...2.5 mm² with cable end, without bezel, 1 wireCaptive screw clamp terminals, removable terminal block flexible cable :  0.5...1.5 mm² with cable end, with double bezel, 2 wires
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SIL 3 conforming to EN/IEC 62061
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24 V DC - 20...20 % |
Breaking Capacity | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output 20 mA at 24 V for static output circuit |
Continuous Power | can reach PL e/category 4 conforming to EN/ISO 13849-1 can reach SIL 3 conforming to EN/IEC 62061 |
Light Block Color | category 4 maximum conforming to EN/IEC 60954-1 |
Number Of Safety Circuits | 3 NO relays per function (6 NO total), volt-free |
Product Or Component Type | safety controller with pre-defined function |
Range Of Product | Preventa Safety automation |
[Uc] Control Circuit Voltage | 24 V |
Function Of Module | configuration 0: functions disabled (factory setting) configuration 1: emergency stop monitoring 1-channel wiring, category 2 configuration 10: enabling grip switch monitoring (3-position switch), category 4 configuration 11: sensing mat and edges monitoring, category 3 configuration 12: sensing mat and edges monitoring, category 3 configuration 13: relay output safety light curtain monitoring, category 4 configuration 14: coded magnetic switch monitoring, category 4 configuration 15: coded magnetic switch monitoring, category 4 configuration 2: emergency stop monitoring 1-channel wiring, category 2 configuration 3: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 configuration 4: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 configuration 5: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 configuration 6: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 configuration 7: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 configuration 8: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4 configuration 9: guard monitoring for injection presses and blowing machines, category 4 |
Mounting Support | 35 mm symmetrical DIN rail |
Number Of Additional Circuits | 3 solid state outputs |
Range Name | Preventa XPS MP, XPS MC, XPS MCM |
Safety Module Application | 2 independent functions |
Safety Module Name | XPSMP |
Type Of Start | automatic or unmonitored (configuration 1) automatic or unmonitored (configuration 10) automatic or unmonitored (configuration 11) automatic or unmonitored (configuration 14) automatic or unmonitored (configuration 3) automatic or unmonitored (configuration 5) automatic or unmonitored (configuration 7) monitored (configuration 12) monitored (configuration 13) monitored (configuration 15) monitored (configuration 2) monitored (configuration 4) monitored (configuration 6) monitored (configuration 8) monitored (configuration 9) |
COMPLEMENTARY | |
Interlocked Device | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output 20 mA at 24 V for static output circuit |
Safety Use Category | category 4 maximum conforming to EN/IEC 60954-1 |
Associated Fuse Rating | 4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
Checks | configuration (configuration 10) configuration (configuration 13) configuration (configuration 3) configuration (configuration 4) configuration (configuration 5) configuration (configuration 6) configuration (configuration 9) |
Connections - Terminals | captive screw clamp terminals, removable terminal block flexible cable: 0.2...1.5 mm² without cable end, 2 wires captive screw clamp terminals, removable terminal block flexible cable: 0.2...2.5 mm² without cable end, 1 wire captive screw clamp terminals, removable terminal block flexible cable: 0.25...1 mm² with cable end, without bezel, 2 wires captive screw clamp terminals, removable terminal block flexible cable: 0.25...2.5 mm² with cable end, with bezel, 1 wire captive screw clamp terminals, removable terminal block flexible cable: 0.25...2.5 mm² with cable end, without bezel, 1 wire captive screw clamp terminals, removable terminal block flexible cable: 0.5...1.5 mm² with cable end, with double bezel, 2 wires captive screw clamp terminals, removable terminal block solid cable: 0.2...1 mm² without cable end, 2 wires captive screw clamp terminals, removable terminal block solid cable: 0.2...2.5 mm² without cable end, 1 wire |
Depth | 114 mm |
Height | 99 mm |
Input Protection Type | internal, electronic |
Local Signalling | 12 LEDs |
Maximum Line Resistance | 100 Ohm <2000 m |
Maximum Response Time On Input Open | 30 ms |
Minimum Output Current | 10 mA for relay output |
Minimum Output Voltage | 17 V for relay output |
Net Weight | 0.32 kg |
Output Thermal Current | 2 A for 1 output and 4 A for the other 2 outputs for relay 3.3 A for all 3 outputs relay simultaneously 6 A for 1 output and 2 A for the other 2 outputs for relay |
Power Consumption In W | 5 W |
Synchronisation Time Between Inputs | 0.5 s (configuration 13) 1.5 s (configuration 14) 1.5 s (configuration 15) 1.5 s (configuration 5) 1.5 s (configuration 6) 1.5 s (configuration 9) unlimited (configuration 3) unlimited (configuration 4) unlimited (configuration 7) unlimited (configuration 8) |
Width | 45 mm |
[Ith] Conventional Free Air Thermal Current | 20 A |
[Uimp] Rated Impulse Withstand Voltage | 4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
[Ui] Rated Insulation Voltage | 300 V (pollution degree 2) conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2 |
ENVIRONMENT | |
Safety Level | can reach PL e/category 4 conforming to EN/ISO 13849-1 can reach SIL 3 conforming to EN/IEC 62061 |
Type Of Output Stage | 3 NO relays per function (6 NO total), volt-free |
Ambient Air Temperature For Operation | -10-55 °C |
Ambient Air Temperature For Storage | -25-85 °C |
IP Degree Of Protection | IP20 (terminals) IP40 (enclosure) |
Product Certifications | BIA CSA UL |
Standards | DIN V VDE 801 + A1 EN/IEC 60204-1 EN/IEC 60947-1 + A11 EN/IEC 60947-5-1 |
OTHER | |
Poles Description | safety controller with pre-defined function |
[Us] Rated Supply Voltage | 24 V DC - 20...20 % |