Loading...
*All information are subjected to changes without prior notice.

XPSBF1132 - Module XPSBF - Two-hand Control - 24 V DC.

Schneider
SKU
SE_XPSBF1132
Model
XPSBF1132

Obsolete

All prices inclusive of GST

Short description of XPSBF1132

XPSBF1132. Safety Modules
Obsolete
range of product : Preventa Safety automation
-  product or component type : Preventa safety module
-  safety module name : XPSBF
-  safety module application : For electrical monitoring of two
- hand control stations
-  function of module : Monitoring two
- hand control station and a foot switch
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
-  safety reliability data : DC > 99 % conforming to EN/ISO 13849-1MTTFd = 50.1 years conforming to EN/ISO 13849-1PFHd = 1.3E
- 8 1/h conforming to EN/IEC 62061
-  connections
-  terminals : Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable endCaptive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable endCaptive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezelCaptive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezelCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable endCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable endCaptive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezelCaptive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
-  output type : Relay, 2 NO circuit(s), volt
- free
-  number of additional circuits : 2 solid state outputs
-  [Us] rated supply voltage : 24 V DC
-  20...20 %
MAIN SPECIFICATIONS
Analogue Input Number24 V DC - 20...20 %
Breaking Capacity1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
20 mA at 24 V for solid state output circuit
Continuous Powercan reach PL e/category 4 conforming to EN/ISO 13849-1
can reach SILCL 3 conforming to EN/IEC 62061
Mounting Diameter1-1 NC + NO
Product Or Component TypePreventa safety module
Range Of ProductPreventa Safety automation
[Uc] Control Circuit Voltage24 V DC
Function Of Modulemonitoring two-hand control station and a foot switch
Mounting Support35 mm symmetrical DIN rail
Number Of Additional Circuits2 solid state outputs
Range NamePreventa XPS
Safety Module Applicationfor electrical monitoring of two-hand control stations
Safety Module NameXPSBF
COMPLEMENTARY
Interlocked Device1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
180 VA holding AC-15 C300 relay output
1800 VA inrush AC-15 C300 relay output
20 mA at 24 V for solid state output circuit
Number Of Inputs1-1 NC + NO
Product Namerelay, 2 NO circuit(s), volt-free
Associated Fuse Rating4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
Connections - Terminalscaptive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end
captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end
captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel
captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel
captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end
captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end
captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel
captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Current Consumption8 mA at 24 V DC on power supply
Input Compatibilitytwo-hand control conforming to EN 574/ISO 13851-III C
Input Protection Typeinternal, electronic
Local Signalling3 LEDs
Maximum Response Time On Input Open20 ms
Minimum Output Current10 mA for relay output
Minimum Output Voltage17 V for relay output
Net Weight0.15 kg
Output Thermal Current4.2 A per relay for relay output
Output Typerelay, 2 NO circuit(s), volt-free
Power Consumption In W2.5 W
Safety Reliability DataDC > 99 % conforming to EN/ISO 13849-1
MTTFd = 50.1 years conforming to EN/ISO 13849-1
PFHd = 1.3E-8 1/h conforming to EN/IEC 62061
Synchronisation Time Between Inputs0.5 s
[Ith] Conventional Free Air Thermal Current8.4 A
[Uimp] Rated Impulse Withstand Voltage4 kV overvoltage category III conforming to DIN VDE 0110 part 1
4 kV overvoltage category III conforming to IEC 60947-5-1
[Ui] Rated Insulation Voltage300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
300 V (pollution degree 2) conforming to IEC 60947-5-1
ENVIRONMENT
Safety Levelcan reach PL e/category 4 conforming to EN/ISO 13849-1
can reach SILCL 3 conforming to EN/IEC 62061
Ambient Air Temperature For Operation-10-55 °C
Ambient Air Temperature For Storage-25-85 °C
IP Degree Of ProtectionIP20 (terminals) conforming to EN/IEC 60529
IP40 (enclosure) conforming to EN/IEC 60529
Product CertificationsCSA
TÜV
UL
StandardsEN 574 type III C/ISO 13851
EN/IEC 60204-1
EN/IEC 60947-5-1
OTHER
Poles DescriptionPreventa safety module
[Us] Rated Supply Voltage24 V DC - 20...20 %