XPSBCE3710P - Module XPSBCE - Two-hand Control - 230 V AC.
Schneider
SKU
SE_XPSBCE3710P
Model
XPSBCE3710P
Obsolete
Short description of XPSBCE3710P
XPSBCE3710P. Safety Modules
Obsolete
range of product : Preventa Safety automation
-  product or component type : Preventa safety module
-  safety module name : XPSBCE
-  safety module application : For electrical monitoring of two
- hand control stations
-  function of module : Monitoring two
- hand control station
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
-  safety reliability data : DC > 99 % conforming to EN/ISO 13849-1MTTFd = 37 years conforming to EN/ISO 13849-1PFHd = 3E
- 8 1/h conforming to EN/IEC 62061
-  connections
-  terminals : Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable endCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable endCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable endCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable end
-  output type : Relay, 2 NO circuit(s), volt
- free
-  number of additional circuits : 1 NC
-  [Us] rated supply voltage : 230 V AC
-  15...10 %
-  product or component type : Preventa safety module
-  safety module name : XPSBCE
-  safety module application : For electrical monitoring of two
- hand control stations
-  function of module : Monitoring two
- hand control station
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
-  safety reliability data : DC > 99 % conforming to EN/ISO 13849-1MTTFd = 37 years conforming to EN/ISO 13849-1PFHd = 3E
- 8 1/h conforming to EN/IEC 62061
-  connections
-  terminals : Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable endCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable endCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable endCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable end
-  output type : Relay, 2 NO circuit(s), volt
- free
-  number of additional circuits : 1 NC
-  [Us] rated supply voltage : 230 V AC
-  15...10 %
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 230 V AC - 15...10 % |
Breaking Capacity | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 160 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
Continuous Power | can reach PL e/category 4 conforming to EN/ISO 13849-1 can reach SILCL 3 conforming to EN/IEC 62061 |
Mounting Diameter | 1-1 NC + NO |
Product Or Component Type | Preventa safety module |
Range Of Product | Preventa Safety automation |
[Uc] Control Circuit Voltage | 24 V DC |
Function Of Module | monitoring two-hand control station |
Mounting Support | 35 mm symmetrical DIN rail |
Number Of Additional Circuits | 1 NC |
Range Name | Preventa XPS |
Safety Module Application | for electrical monitoring of two-hand control stations |
Safety Module Name | XPSBCE |
COMPLEMENTARY | |
Interlocked Device | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 160 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
Number Of Inputs | 1-1 NC + NO |
Product Name | relay, 2 NO circuit(s), volt-free |
Associated Fuse Rating | 6 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
Connections - Terminals | captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² flexible without cable end captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
Input Compatibility | two-hand control conforming to EN 574/ISO 13851-III C |
Input Protection Type | internal, electronic |
Local Signalling | 3 LEDs |
Maximum Response Time On Input Open | 50 ms |
Minimum Output Current | 10 mA for relay output |
Minimum Output Voltage | 17 V for relay output |
Net Weight | 0.322 kg |
Output Type | relay, 2 NO circuit(s), volt-free |
Power Consumption In VA | 4 VA |
Safety Reliability Data | DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 37 years conforming to EN/ISO 13849-1 PFHd = 3E-8 1/h conforming to EN/IEC 62061 |
Supply Frequency | 50/60 Hz |
Synchronisation Time Between Inputs | 0.5 s |
[Ith] Conventional Free Air Thermal Current | 6 A |
[Uimp] Rated Impulse Withstand Voltage | 4 kV overvoltage category III conforming to DIN VDE 0110 part 1 4 kV overvoltage category III conforming to IEC 60947-5-1 |
[Ui] Rated Insulation Voltage | 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 300 V (pollution degree 2) conforming to IEC 60947-5-1 |
ENVIRONMENT | |
Safety Level | can reach PL e/category 4 conforming to EN/ISO 13849-1 can reach SILCL 3 conforming to EN/IEC 62061 |
Ambient Air Temperature For Operation | -25-55 °C |
Ambient Air Temperature For Storage | -25-75 °C |
IP Degree Of Protection | IP20 (terminals) conforming to EN/IEC 60529 IP40 (enclosure) conforming to EN/IEC 60529 |
Product Certifications | BG CSA UL |
Standards | EN 574 type III C/ISO 13851 EN/IEC 60204-1 EN/IEC 60947-5-1 |
OTHER | |
Poles Description | Preventa safety module |
[Us] Rated Supply Voltage | 230 V AC - 15...10 % |