XPSAXE5120C - Module XPSAXE - Stop and Switch Monitoring - 24 V DC.
Schneider
SKU
SE_XPSAXE5120C
Model
XPSAXE5120C
SGD $333.10 All prices inclusive of GST
Short description of XPSAXE5120C
XPSAXE5120C. Safety Modules
Country of Origin
Germany
range of product : Preventa Safety automation
-  product or component type : Preventa safety module
-  safety module name : XPSAXE
-  safety module application : For emergency stop and switch monitoring
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
-  safety reliability data : DC > 99 % conforming to EN/ISO 13849-1MTTFd = 457 years conforming to EN/ISO 13849-1PFHd = 3E
- 8 1/h conforming to EN/IEC 62061
-  connections
-  terminals : Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable endSpring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable endSpring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezelSpring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezelSpring terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with double bezelSpring terminals, removable terminal block
-  output type : Relay instantaneous opening, 3 NO circuit(s), volt
- free
-  number of additional circuits : 1 NC
-  [Us] rated supply voltage : 24 V DC-15...10 %24 V AC
-  product or component type : Preventa safety module
-  safety module name : XPSAXE
-  safety module application : For emergency stop and switch monitoring
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
-  safety reliability data : DC > 99 % conforming to EN/ISO 13849-1MTTFd = 457 years conforming to EN/ISO 13849-1PFHd = 3E
- 8 1/h conforming to EN/IEC 62061
-  connections
-  terminals : Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable endSpring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable endSpring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezelSpring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezelSpring terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with double bezelSpring terminals, removable terminal block
-  output type : Relay instantaneous opening, 3 NO circuit(s), volt
- free
-  number of additional circuits : 1 NC
-  [Us] rated supply voltage : 24 V DC-15...10 %24 V AC
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24 V AC 24 V DC - 15...10 % |
Breaking Capacity | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
Continuous Power | can reach PL e/category 4 conforming to EN/ISO 13849-1 can reach SILCL 3 conforming to EN/IEC 62061 |
Product Or Component Type | Preventa safety module |
Range Of Product | Preventa Safety automation |
[Uc] Control Circuit Voltage | 24 V DC |
Mounting Support | 35 mm symmetrical DIN rail |
Number Of Additional Circuits | 1 NC |
Range Name | Preventa XPS |
Safety Module Application | for emergency stop and switch monitoring |
Safety Module Name | XPSAXE |
COMPLEMENTARY | |
Interlocked Device | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
Product Name | relay instantaneous opening, 3 NO circuit(s), volt-free |
Associated Fuse Rating | 6 A gG for instantaneous outputs |
Connections - Terminals | spring terminals, removable terminal block spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel spring terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with double bezel |
Local Signalling | 2 LEDs |
Maximum Power Consumption In VA | 4 VA DC |
Maximum Response Time On Input Open | 80 ms |
Minimum Output Current | 10 mA for relay output |
Minimum Output Voltage | 17 V for relay output |
Net Weight | 0.229 kg |
Output Thermal Current | 6 A for instantaneous and time delay outputs |
Output Type | relay instantaneous opening, 3 NO circuit(s), volt-free |
Safety Reliability Data | DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 457 years conforming to EN/ISO 13849-1 PFHd = 3E-8 1/h conforming to EN/IEC 62061 |
Supply Frequency | 50/60 Hz |
Synchronisation Time Between Inputs | < 0.5 s |
[Uimp] Rated Impulse Withstand Voltage | 4 kV overvoltage category III conforming to DIN VDE 0110 part 1 4 kV overvoltage category III conforming to IEC 60947-5-1 |
[Ui] Rated Insulation Voltage | 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 300 V (pollution degree 2) conforming to IEC 60947-5-1 |
ENVIRONMENT | |
Safety Level | can reach PL e/category 4 conforming to EN/ISO 13849-1 can reach SILCL 3 conforming to EN/IEC 62061 |
Ambient Air Temperature For Operation | -25-55 °C |
Ambient Air Temperature For Storage | -25-75 °C |
IP Degree Of Protection | IP20 conforming to EN/IEC 60529 IP40 conforming to EN/IEC 60529 |
Product Certifications | BG CSA UL |
Standards | EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 13850 |
OTHER | |
Poles Description | Preventa safety module |
[Us] Rated Supply Voltage | 24 V AC 24 V DC - 15...10 % |
Write Your Own Review