XPSAV11113P - Module XPSAV - Emergency Stop - 24 V DC, Time Delay 0...300 S.
Schneider
SKU
SE_XPSAV11113P
Model
XPSAV11113P
Obsolete
Short description of XPSAV11113P
XPSAV11113P. Safety Modules
Obsolete
range of product : Preventa Safety automation
-  product or component type : Preventa safety module
-  safety module name : XPSAV
-  safety module application : For emergency stop and switch monitoring
-  function of module : Monitoring of a movable guard associated with 2 switches automatic startEmergency stop monitoring 1-channel wiringEmergency stop button with 1 NC contact, automatic start or unmonitored startEmergency stop monitoring 2-channel wiringEmergency stop button with 2 NC contacts, monitored start
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
-  safety reliability data : DC > 99 % conforming to EN/ISO 13849-1MTTFd = 75.8 years conforming to EN/ISO 13849-1PFHd = 7.95E
- 9 1/h conforming to EN/IEC 62061
-  type of start : Configurable
-  connections
-  terminals : Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
-  output type : Relay instantaneous opening, 3 NO circuit(s), volt
- freeRelay time delay opening, 3 NO circuit(s), volt
- free
-  number of additional circuits : 3 solid state outputs
-  [Us] rated supply voltage : 24 V DC
-  20...20 %
-  product or component type : Preventa safety module
-  safety module name : XPSAV
-  safety module application : For emergency stop and switch monitoring
-  function of module : Monitoring of a movable guard associated with 2 switches automatic startEmergency stop monitoring 1-channel wiringEmergency stop button with 1 NC contact, automatic start or unmonitored startEmergency stop monitoring 2-channel wiringEmergency stop button with 2 NC contacts, monitored start
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
-  safety reliability data : DC > 99 % conforming to EN/ISO 13849-1MTTFd = 75.8 years conforming to EN/ISO 13849-1PFHd = 7.95E
- 9 1/h conforming to EN/IEC 62061
-  type of start : Configurable
-  connections
-  terminals : Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
-  output type : Relay instantaneous opening, 3 NO circuit(s), volt
- freeRelay time delay opening, 3 NO circuit(s), volt
- free
-  number of additional circuits : 3 solid state outputs
-  [Us] rated supply voltage : 24 V DC
-  20...20 %
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24 V DC - 20...20 % |
Breaking Capacity | 1.25 A at 24 V (DC-13) time constant: 50 ms for relay output 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output 20 mA at 24 V |
Continuous Power | can reach PL e/category 4 conforming to EN/ISO 13849-1 can reach SILCL 3 conforming to EN/IEC 62061 |
Product Or Component Type | Preventa safety module |
Range Of Product | Preventa Safety automation |
Thread Type | 0...300 s |
[Uc] Control Circuit Voltage | 24 V DC |
Function Of Module | emergency stop button with 1 NC contact, automatic start or unmonitored start emergency stop button with 2 NC contacts, monitored start emergency stop monitoring 1-channel wiring emergency stop monitoring 2-channel wiring monitoring of a movable guard associated with 2 switches automatic start |
Mounting Support | 35 mm symmetrical DIN rail |
Number Of Additional Circuits | 3 solid state outputs |
Range Name | Preventa XPS |
Safety Module Application | for emergency stop and switch monitoring |
Safety Module Name | XPSAV |
Type Of Start | configurable |
COMPLEMENTARY | |
Interlocked Device | 1.25 A at 24 V (DC-13) time constant: 50 ms for relay output 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output 20 mA at 24 V |
Product Name | relay instantaneous opening, 3 NO circuit(s), volt-free relay time delay opening, 3 NO circuit(s), volt-free |
Time Delay Range | 0...300 s |
Associated Fuse Rating | 4 A gG or gL for instantaneous and time delay outputs conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
Connections - Terminals | captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
Input Protection Type | internal, electronic |
Local Signalling | 11 LEDs |
Maximum Line Resistance | 100 Ohm <2000 m |
Maximum Power Consumption In W | 5 W DC |
Maximum Response Time On Input Open | 30 ms |
Minimum Output Current | 10 mA for relay output |
Minimum Output Voltage | 17 V for relay output |
Net Weight | 0.32 kg |
Output Thermal Current | 2 A for 1 output and 4 A for the other 2 outputs for instantaneous and time delay outputs 3.3 A for all 3 outputs for instantaneous and time delay outputs 6 A for 1 output and 2 A for the other 2 outputs for instantaneous and time delay outputs |
Output Type | relay instantaneous opening, 3 NO circuit(s), volt-free relay time delay opening, 3 NO circuit(s), volt-free |
Safety Reliability Data | DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 75.8 years conforming to EN/ISO 13849-1 PFHd = 7.95E-9 1/h conforming to EN/IEC 62061 |
Synchronisation Time Between Inputs | 1.5 s for guard unlimited for emergency stop |
[Ith] Conventional Free Air Thermal Current | 20 A |
[Uimp] Rated Impulse Withstand Voltage | 4 kV overvoltage category III conforming to DIN VDE 0110 part 1 4 kV overvoltage category III conforming to IEC 60947-5-1 |
[Ui] Rated Insulation Voltage | 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 300 V (pollution degree 2) conforming to IEC 60947-5-1 |
ENVIRONMENT | |
Safety Level | can reach PL e/category 4 conforming to EN/ISO 13849-1 can reach SILCL 3 conforming to EN/IEC 62061 |
Ambient Air Temperature For Operation | -10-55 °C |
Ambient Air Temperature For Storage | -25-85 °C |
IP Degree Of Protection | IP20 (terminals) conforming to EN/IEC 60529 IP40 (enclosure) conforming to EN/IEC 60529 |
Product Certifications | CSA TÜV UL |
Standards | EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 13850 |
OTHER | |
Poles Description | Preventa safety module |
[Us] Rated Supply Voltage | 24 V DC - 20...20 % |