XPSAF5130 - Module XPSAF - Emergency Stop - 24 V AC DC.
Schneider
SKU
SE_XPSAF5130
Model
XPSAF5130
Obsolete
Short description of XPSAF5130
XPSAF5130. Safety Modules
Obsolete
range of product : Preventa Safety automation
-  product or component type : Preventa safety module
-  safety module name : XPSAF
-  safety module application : For emergency stop and switch monitoring
-  function of module : Emergency stop monitoring 1-channel wiringEmergency stop monitoring 2-channel wiringMonitoring of a movable guard
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach category 3 conforming to EN/IEC 62061
-  safety reliability data : DC > 99 % conforming to EN/ISO 13849-1MTTFd = 243 years conforming to EN/ISO 13849-1PFHd = 4.62E
- 9 1/h conforming to EN/IEC 62061
-  type of start : Configurable
-  connections
-  terminals : Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezelCaptive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
-  output type : Relay instantaneous opening, 3 NO circuit(s), volt
- free
-  number of additional circuits : 0
-  [Us] rated supply voltage : 24 V AC
-  15...10 %24 V DC-15...10 %
-  product or component type : Preventa safety module
-  safety module name : XPSAF
-  safety module application : For emergency stop and switch monitoring
-  function of module : Emergency stop monitoring 1-channel wiringEmergency stop monitoring 2-channel wiringMonitoring of a movable guard
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach category 3 conforming to EN/IEC 62061
-  safety reliability data : DC > 99 % conforming to EN/ISO 13849-1MTTFd = 243 years conforming to EN/ISO 13849-1PFHd = 4.62E
- 9 1/h conforming to EN/IEC 62061
-  type of start : Configurable
-  connections
-  terminals : Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezelCaptive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezelCaptive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
-  output type : Relay instantaneous opening, 3 NO circuit(s), volt
- free
-  number of additional circuits : 0
-  [Us] rated supply voltage : 24 V AC
-  15...10 %24 V DC-15...10 %
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24 V AC - 15...10 % 24 V DC - 15...10 % |
Breaking Capacity | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
Continuous Power | can reach category 3 conforming to EN/IEC 62061 can reach PL e/category 4 conforming to EN/ISO 13849-1 |
Product Or Component Type | Preventa safety module |
Range Of Product | Preventa Safety automation |
[Uc] Control Circuit Voltage | 24 V |
Function Of Module | emergency stop monitoring 1-channel wiring emergency stop monitoring 2-channel wiring monitoring of a movable guard |
Mounting Support | 35 mm symmetrical DIN rail |
Range Name | Preventa XPS |
Safety Module Application | for emergency stop and switch monitoring |
Safety Module Name | XPSAF |
Type Of Start | configurable |
COMPLEMENTARY | |
Interlocked Device | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
Product Name | relay instantaneous opening, 3 NO circuit(s), volt-free |
Associated Fuse Rating | 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
Connections - Terminals | captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
Current Consumption | 30 mA at 24 V AC on power supply |
Input Protection Type | internal, electronic |
Local Signalling | 3 LEDs |
Maximum Line Resistance | 90 Ohm |
Maximum Power Consumption In VA | 5 VA AC |
Maximum Response Time On Input Open | 40 ms |
Minimum Output Current | 10 mA for relay output |
Minimum Output Voltage | 17 V for relay output |
Net Weight | 0.25 kg |
Output Thermal Current | 6 A per relay for relay output |
Output Type | relay instantaneous opening, 3 NO circuit(s), volt-free |
Safety Reliability Data | DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 243 years conforming to EN/ISO 13849-1 PFHd = 4.62E-9 1/h conforming to EN/IEC 62061 |
Supply Frequency | 50/60 Hz |
Synchronisation Time Between Inputs | unlimited |
[Ith] Conventional Free Air Thermal Current | 18 A |
[Uimp] Rated Impulse Withstand Voltage | 4 kV overvoltage category III conforming to DIN VDE 0110 part 1 4 kV overvoltage category III conforming to IEC 60947-5-1 |
[Ui] Rated Insulation Voltage | 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 300 V (pollution degree 2) conforming to IEC 60947-5-1 |
ENVIRONMENT | |
Safety Level | can reach category 3 conforming to EN/IEC 62061 can reach PL e/category 4 conforming to EN/ISO 13849-1 |
Ambient Air Temperature For Operation | -25-60 °C |
Ambient Air Temperature For Storage | -40-85 °C |
IP Degree Of Protection | IP20 (terminals) conforming to EN/IEC 60529 IP40 (enclosure) conforming to EN/IEC 60529 |
Product Certifications | CSA TÜV UL |
Standards | EN 1088/ISO 14119 EN 60204-1 EN/IEC 60947-5-1 EN/ISO 13850 |
OTHER | |
Poles Description | Preventa safety module |
[Us] Rated Supply Voltage | 24 V AC - 15...10 % 24 V DC - 15...10 % |