Singapore GST will increase from 8% to 9%

(Effective from Jan 1, 2024)

Electgo: Your trusted Source for Electrical Components in Singapore

An Authorized Supplier Offering a Comprehensive Range of Electrical Component Categories

Loading...

Power Factor Controller - VarPlus Logic - VPL 12

Schneider
SKU
SE_VPL12N
Model
VPL12N
SGD $1,215.80

Short description of VPL12N

VARPLUS LOGIC CONTROLLER, 12 STEP OUTPUT
Country of Origin
Germany
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
Power Factor controller
-  VarPlus Logic
-  VPL 12.
Label :  VarPlus Logic
-  range :  VarPlus
-  product name :  VarPlus Logic
-  device short name :  VPL12
-  product or component type :  power factor controller
-  Range Presentation :  VarPlus Logic offers a fast, reliable and safe power factor correction while monitoring the real time data of your system and alerting on preventive maintenance.
Technical data
-  90-550 V direct voltage input
-  1A or 5A CT secondary compatible with 15 mA sensitivity
-  4 quadrant operation – Suitable for operation with energy import and export
-  No restriction in step sequence
-  Inbuilt temperature monitor with fan control and alarm
-  Dedicated alarm contact and fan control relay
-  Automatic initialization and automatic step detection for fast and easy commissioning
-  Communication – RS485 communication in Modbus protocol
-  Digital inputs to control dual cos phiMeasurement
-  Active, reactive & apparent power (kW, kVA, kvar)
-  Power factor, voltage and current
-  Total voltage harmonic distortion & individual harmonics up to 19th harmonic
-  Present cabinet temperature and maximum temperature since reset
-  Step data monitoringAlarms
-  Over/under voltage, low/high current, under/over compensation alarms
-  Faulty step alarm with step number
-  Individual step derating of capacitor indicator
-  High temperature alarm, through an internal thermal sensor
-  Total harmonic distortion alarm at 7% THDu
-  Operational hours & operational counter alarm
-  Hunting alarmMechanical data
-  Flush mounting
-  Degree of protection
-  IP 41 (front) & IP 20 (rear)
-  Range Benefits :  Maintain power factor to avoid penalty
-  Optimise the preventive maintenance
-  Monitoring of all the connected capacitor steps with real time power in kvar
-  Remaining step capacity as a % of the original power since installation
-  Number of switching operations of every connected stepHassle free commissioning of capacitor bank
-  3 step commissioning process in stable loads
-  Automatic initialization and step detection
-  Automatic correction of connection errors while installationFlexibility for design of capacitor banks / Flexibility in retrofitting
-  Easy design of capacitor bank
-  No step sequence restriction like in the traditional relays
-  Easy retrofit with any available capacitorsSeamless integration
-  Easy monitoring, alarm and control
-  Integration in your existing Schneider Electric solution software or gateways, with RS485 Modbus protocol
-  Monitoring of network parameters, temperature, harmonics with 12 different alarms
-  Automatic corrections by switching off steps in case of any system abnormality
-  Range Application Presentation :  Automatic Power Factor Correction (APFC) systems.
-  Automatic power factor compensation with capacitors alone
-  Automatic power factor compensation with capacitors and detuned reactors
MAIN SPECIFICATIONS
Analogue Input Number<= 999 kV AC with external VT
90...550 V AC
Display Size56 x 25 mm
Display Typebacklit LCD
Measurement Accuracycos φ +/- 2 %
current +/- 1 %
energy (P,Q,S) +/- 2 %
frequency +/- 1 %
individual voltage harmonic +/- 3 %
temperature +/- 3 °C
total voltage harmonic distortion THD (U) +/- 2 %
voltage +/- 1 %
Product Or Component Typepower factor controller
Thread Type1...6500 s (on reconnection)
1...6500 s (on response)
Device Short NameVPL12
EAN133606480800115
Function Availableadvanced programming (expert)
any step sequence
automatic detection
automatic initialisation
manual programming
Mounting Supportpanel - thickness: 1-3 mm
RangePowerLogic
Range NameVarPlus Logic
Type Of Measurementambient temperature inside the cubicle
capacitor current overload Irms/I1
cos φ
individual voltage harmonic
operating time
power factor
tan φ
COMPLEMENTARY
Analogue Output Numberbacklit LCD
Humidity Setting Range56 x 25 mm
Product NamePowerLogic PFC Controller
Time Delaycos φ +/- 2 %
current +/- 1 %
energy (P,Q,S) +/- 2 %
frequency +/- 1 %
individual voltage harmonic +/- 3 %
temperature +/- 3 °C
total voltage harmonic distortion THD (U) +/- 2 %
voltage +/- 1 %
Time Delay Range1...6500 s (on reconnection)
1...6500 s (on response)
Colour Codefront: dark grey RAL 7016
Compatibility CodeVPL 12
Current Of Common10 A
Cut-out Dimensions138 x 138 mm
Data Recording5 alarms
Depth58 mm
Device Connectioncommunication protocol: Modbus interface: RS485
Height144 mm
Information Displayedindividual step size in kVAr
number of switching cycles per step
remaining step capacity in %
Input Functionswitch: 1 x dry contact
Input Typecurrent input CT...X/5 A and X/1 A
insensitive to CT polarity
insensitive to phase rotation polarity
phase to neutral
phase to phase
Measurement Current0-5 A
Measurement Voltage90-550 V AC 50/60 Hz
Mechanical Durability65000 cycles without maintenance
Metering Typeactive power P, P1, P2, P3 on load
apparent power S, S1, S2, S3 on load
phase current I1, I2, I3 RMS on load
power factor and displacement PF (signed, four quadrant)
power factor average over lifetime
reactive power Q, Q1, Q2, Q3 on load
temperature maximum
total current harmonic distortion THD (I)
voltage U21, U32, U13, V1, V2, V3 on load
Mounting Locationin cabinet
Mounting Modeflush-mounted
Net Weight0.6 kg
Number Of Quadrant Operation For Generator Application4
Number Of Step Output Contacts12
Operating Modemanual or automatic
Output Typealarm relay: 1 A 48 V DC
alarm relay: 5 A 250 V AC 50/60 Hz
control relay: 0.2 A 110 V DC
control relay: 1 A 24 V DC
control relay: 1 A 48 V DC
control relay: 2 A 400 V AC 50/60 Hz
control relay: 5 A 120 V AC 50/60 Hz
control relay: 5 A 250 V AC 50/60 Hz
fan: 1 A 48 V DC
fan: 5 A 250 V AC 50/60 Hz
Provided Equipmentuser manual
Service Life In Hours100000 h without maintenance
Settings Operating Modeautomatic
manual
Type Of Alarmscapacitor current overload (Irms/I1) (> 130 % I1) / Action: message and alarm contact + step switched off
high current (> 6 A CT) / Action: message and alarm contact
hunting (unstable regulation) / Action: message and alarm contact + step blocked
low current (< 15 mA CT) / Action: message and alarm contact
overcompensation / Action: message and alarm contact
overtemperature (30 °C) / Action: fan switch
overtemperature (50 °C) / Action: message and alarm contact + step switched off
overvoltage (+/- 10 %) / Action: message and alarm contact + control stopped
step faulty / Action: message and alarm contact + step blocked
step power loss (< 75 %) / Action: message and alarm contact + step blocked
total harmonic distortion (> 7 %) / Action: message and alarm contact + step switched off
Type Of Settingchoice of stepping programs: auto
choice of stepping programs: LIFO
choice of stepping programs: linear
delay between 2 successive switch on the same step: 5...1200 s
step configuration programming: auto
step configuration programming: fixed
step configuration programming: off
target cos phi: 0.7 inductive...0.7 capacitive
target cos phi: dual cos φ
Width144 mm
ENVIRONMENT
Ambient Air Temperature For Operation-20-60 °C
Ambient Air Temperature For Storage-40-85 °C
IP Degree Of Protectionfront face: IP41
rear face: IP20
Operating Altitude<= 2000 m
Product CertificationsCE
cNRTL
EAC
NRTL
StandardsEN 61010-1
IEC 61000-6-2
IEC 61000-6-4
IEC 61326-1
UL 61010-1
OTHER
Poles Descriptionpower factor controller
[Us] Rated Supply Voltage<= 999 kV AC with external VT
90...550 V AC
Write Your Own Review