TMC4TI2 - Analogue Input Cartridge, Modicon M241, 2 Temperature Inputs.
Schneider
SKU
SE_TMC4TI2
Model
TMC4TI2
SGD $324.91 All prices inclusive of GST
Short description of TMC4TI2
TMC4TI2. For performance-demanding applications
Country of Origin
Indonesia
range of product : Modicon M241
-  product or component type : Analogue input cartridge
-  product compatibility : Modicon M241C
-  analogue input number : 2
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  product or component type : Analogue input cartridge
-  product compatibility : Modicon M241C
-  analogue input number : 2
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 2 |
Analogue Input Range | 2 |
Product Or Component Type | analogue input cartridge |
Range Of Product | Modicon M241 |
Analogue Input Resolution | 14 bits |
Range Name | Logic Controller - Modicon M241 |
COMPLEMENTARY | |
Analogue Input Type | thermocouple - 200...1000 °C with thermocouple J thermocouple - 200...1300 °C with thermocouple K thermocouple - 200...1300 °C with thermocouple N thermocouple - 200...400 °C with thermocouple T thermocouple - 200...800 °C with thermocouple E thermocouple 0...1760 °C with thermocouple R thermocouple 0...1760 °C with thermocouple S thermocouple 0...1820 °C with thermocouple B Ni 100/Ni 1000 temperature probe - 60...180 °C Pt 100 temperature probe - 200...850 °C Pt 1000 temperature probe - 200...600 °C |
Output Voltage | thermocouple - 200...1000 °C with thermocouple J thermocouple - 200...1300 °C with thermocouple K thermocouple - 200...1300 °C with thermocouple N thermocouple - 200...400 °C with thermocouple T thermocouple - 200...800 °C with thermocouple E thermocouple 0...1760 °C with thermocouple R thermocouple 0...1760 °C with thermocouple S thermocouple 0...1820 °C with thermocouple B Ni 100/Ni 1000 temperature probe - 60...180 °C Pt 100 temperature probe - 200...850 °C Pt 1000 temperature probe - 200...600 °C |
Absolute Accuracy Error | +/- 0.1 % of full scale at 25 °C for thermocouple B 400...1280 °C +/- 0.2 % of full scale at 25 °C for thermocouple B 250...400 °C +/- 0.2 % of full scale at 25 °C for thermocouple E - 200...800 °C +/- 0.2 % of full scale at 25 °C for thermocouple J - 200...1000 °C +/- 0.2 % of full scale at 25 °C for thermocouple K - 200...1300 °C +/- 0.2 % of full scale at 25 °C for thermocouple N - 200...1300 °C +/- 0.2 % of full scale at 25 °C for thermocouple R, S 0...1760°C +/- 0.2 % of full scale at 25 °C for thermocouple T - 200...400 °C +/- 0.5 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe |
Cross Talk | 80 dB |
Depth | 21 mm |
Electrical Connection | 1 x 1.5 mm² 1 spring terminal block with pitch 3.81 mm adjustment for outputs and supply |
Height | 50 mm |
Immunity To Microbreaks | 10 ms |
Input Impedance | >= 1 MOhm |
Insulation | between input and internal logic at 500 V DC non-insulated between inputs |
Local Signalling | 1 LED (green) for PWR |
LSB Value | 0.1 °C |
Maximum Cable Distance Between Devices | twisted shielded pairs cable: <30 m for input |
Net Weight | 0.055 kg |
Non-linearity | +/- 0.05 %FS |
Permissible Continuous Overload | 6 V |
Product Compatibility | Modicon M241C |
Repeat Accuracy | +/- 0.1 %FS |
Sampling Duration | 100 ms |
Supply Voltage Limits | 20.4-28.8 V |
Temperature Drift | +/- 0.008 %FS/°C |
Type Of Cable | twisted shielded pairs cable |
Width | 34 mm |
OTHER | |
Poles Description | analogue input cartridge |
[Us] Rated Supply Voltage | Modicon M241 |