PowerLogic PM8000 - PM8240 Panel Mount Meter - Intermediate Metering.

Schneider
SKU
SE_METSEPM8240
Model
METSEPM8240
SGD $5,911.20

Short description of METSEPM8240

Simplifying power quality, maximizing versatility
Country of Origin
Canada
-
+

UOM: Piece

In stock
In Stock 1
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
range : PowerLogic
-  product name : PowerLogic PM8000
-  device short name : PM8240
-  product or component type : Power meter
MAIN SPECIFICATIONS
Analogue Input Number110...415 V DC +/- 10 %
90...415 V AC 45...65 Hz +/- 10 %
Contacts Type And Composition1 A
10 A
5 A
Control Type1P + N
3P
3P + N
Display Typecolour TFT LCD
Measurement Accuracyactive energy +/- 0.2 %
current +/- 0.1 %
voltage +/- 0.1 %
Mounting Diameter3 digital 30 V AC
3 digital 60 V DC
Product Or Component Typepower meter
Web Server512 MB
[Uc] Control Circuit VoltageIPv6 (internet protocol)
Communication Port ProtocolDNP3
Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
IEC 61850
ION at 115 kbauds - 2-wire
Modbus RTU at 115 kbauds - 2-wire
Modbus TCP/IP
RSTP 801.1d 2004
Device Short NamePM8240
Mounting Supportframework
Power Quality Analysis conforming to EN 50160: 2010 compliance report
conforming to IEC 61000-4-30: class S power quality measurement
conforming to IEC 62586 power quality monitoring
conforming to IEEE 519: 2014 compliance report
harmonic distortion
programmablity (logic and math functions)
up to the 63rd harmonic
voltage sag and swell detection
waveform capture
RangePowerLogic
Range NamePowerLogic PM8000 series
Type Of Measurementactive and reactive power per phase, rms
active and reactive power total
apparent power per phase, rms
apparent power total
current
frequency
power factor per phase, rms
power factor total
voltage
COMPLEMENTARY
Analogue Input Typecurrent (impedance 0.3 mOhm)
voltage (impedance 5 MOhm)
Analogue Output Numbercolour TFT LCD
Communication Gateway320 x 240 pixels QVGA
Communication Network TypeIPv6 (internet protocol)
Display Resolution320 x 240 pixels QVGA
Memory Capacity512 MB
Number Of Inputs3 digital 30 V AC
3 digital 60 V DC
Output Voltagecurrent (impedance 0.3 mOhm)
voltage (impedance 5 MOhm)
Product NamePowerLogic PM8000
Time Delayactive energy +/- 0.2 %
current +/- 0.1 %
voltage +/- 0.1 %
[In] Rated Current1 A
10 A
5 A
Accuracy Classclass 0.2 active energy conforming to ANSI C12.20
class 0.2 active power conforming to IEC 61557-12
class 0.2 current conforming to IEC 61557-12
class 0.2 voltage conforming to IEC 61557-12
class 0.2S active energy conforming to IEC 62053-22
class 0.5 power factor conforming to IEC 61557-12
class 0.5S reactive energy conforming to IEC 62053-24
Communication Port SupportEthernet
screw terminal block: RS485
Communication ServiceDHCP
NTP time synchronization
PTP time synchronization
RSTP support
SMTP e-mail notification
Compatibility CodePM8240
Cybersecurityenable/disable communication ports
password protection
port hardening
robust security logs
Syslog protocol support
Data Recordingalarm logs
data logs
event logs
GPS synchronisation
harmonics logs
min/max of instantaneous values
sag and swell logs
sequence of event recording
time stamping
trending/forecasting
waveform logs
Depth77.5 mm
Device Applicationpower monitoring
WAGES metering
Frequency Measurement Range42-69 Hz
Height96 mm
Information Displayedcurrent
energy consumption
frequency
harmonic distortion
power
voltage
Isolation VoltageIII347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
III347-600 V conforming to UL 61010-1:ed. 3
III400-690 V conforming to EN 61010-1:ed. 3
III400-690 V conforming to IEC 61010-1:ed. 3
Market Segmentbuildings large building cost management: billing: sub feeder
buildings large building network management: main incomer
buildings large building network management: sub feeder
buildings medium building network management: main incomer
buildings multi-site network management: main incomer
buildings multi-site network management: sub feeder
buildings small building network management: main incomer
data center network management: main incomer
data center network management: sub feeder
healthcare network management: main incomer
healthcare network management: sub feeder
industry network management: main incomer
industry network management: sub feeder
utility: sub feeder
Measurement Current50-10000 mA
Measurement Voltage100-690 V AC 42...69 Hz between phases
57-400 V AC 42...69 Hz between phase and neutral
Mounting Modeflush-mounted
Net Weight581 g
Network Frequency50 Hz
60 Hz
Number Of Outputs1 pulse
Power Consumption In VA18 VA at 415 V AC
Sampling Rate256 samples/cycle
Web Servicesalarm notification by e-mail
customizable home page
file upload/download via FTP
file upload/download via SFTP
HTTPS server
viewing of captured waveform (FTP)
viewing of captured waveform (web)
web server
Width96 mm
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-85 °C
Electromagnetic Compatibilityconducted and radiated emissions conforming to EN 55011
conducted and radiated emissions conforming to EN 55022
conducted and radiated emissions conforming to FCC part 15
conducted and radiated emissions conforming to ICES-003
conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579
conducted RF disturbances conforming to IEC 61000-4-6
electrical fast transient/burst immunity test conforming to IEC 61000-4-4
electrostatic discharge conforming to IEC 61000-4-2
immunity to impulse waves conforming to IEC 61000-4-12
magnetic field at power frequency conforming to IEC 61000-4-8
radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
surge immunity test conforming to IEC 61000-4-5
surge withstand conforming to IEEE C37.90.1
voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Installation CategoryIII
IP Degree Of ProtectionIP30 body: conforming to IEC 60529
IP54 front: conforming to IEC 60529
Operating Altitude3000 m
Product CertificationsCE
cULus
N998
Relative Humidity5-95 %
StandardsIEC 61326-1
IEC 61557-12
IEC 62052-11
IEC 62053-22
IEC 62053-24
IEC 62586-2
IEEE 1588
OTHER
Poles Description1P + N
3P
3P + N
[Us] Rated Supply Voltage110...415 V DC +/- 10 %
90...415 V AC 45...65 Hz +/- 10 %
Write Your Own Review
You're reviewing:PowerLogic PM8000 - PM8240 Panel Mount Meter - Intermediate Metering.
Your Rating