METSEPM5570 - PM5570 Meter, 2 Ethernet, Up To 63th H, 1,1M 2DI/2AI/2DO 52 Alarms
Schneider
SKU
SE_METSEPM5570
Model
METSEPM5570
SGD $2,689.77 All prices inclusive of GST
Short description of METSEPM5570
METSEPM5570. PM5570, PANEL MOUNT, ANALOG INPUTS
Country of Origin
India
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 100...480 V AC 45...65 Hz 125...250 V DC |
Contacts Type And Composition | 1 A 5 A |
Control Type | 1P + N 3P 3P + N |
Display Type | backlit LCD |
Measurement Accuracy | active energy +/- 0.2 % active power +/- 0.2 % apparent power +/- 0.5 % current +/- 0.1 % frequency +/- 0.05 % power factor +/- 0.005 reactive energy +/- 1 % voltage +/- 0.1 % |
Mounting Diameter | 2 analog 2 digital |
Number Of Doors | Ethernet/serial |
Product Or Component Type | power meter |
Web Server | 1.1 MB |
Communication Port Protocol | BACnet IP Ethernet Modbus TCP/IP daisy chain JBUS Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V |
Device Short Name | PM5570 |
EAN13 | 3606489869694 |
Mounting Support | framework |
Power Quality Analysis | up to the 63rd harmonic |
Range | PowerLogic |
Range Name | PM5000 series |
Type Of Measurement | active and reactive power current energy frequency power factor voltage |
COMPLEMENTARY | |
Analogue Input Type | current (impedance 0.3 mOhm) voltage (impedance 5 MOhm) |
Analogue Output Number | backlit LCD |
Communication Gateway | Ethernet/serial |
Display Resolution | 128 x 128 pixels |
Memory Capacity | 1.1 MB |
Number Of Inputs | 2 analog 2 digital |
Output Voltage | current (impedance 0.3 mOhm) voltage (impedance 5 MOhm) |
Product Name | PowerLogic PM5000 |
Time Delay | active energy +/- 0.2 % active power +/- 0.2 % apparent power +/- 0.5 % current +/- 0.1 % frequency +/- 0.05 % power factor +/- 0.005 reactive energy +/- 1 % voltage +/- 0.1 % |
[In] Rated Current | 1 A 5 A |
Accuracy Class | class 0.2S active energy conforming to IEC 62053-22 |
Communication Port Support | Ethernet RS485 |
Compatibility Code | PM5570 |
Connections - Terminals | control circuit: screw terminal block2 current transformer: screw terminal block6 digital input: screw terminal block8 digital output: screw terminal block4 Ethernet network: RJ45 connector2 RS485 link: screw terminal block4 voltage circuit: screw terminal block4 |
Data Recording | alarm logs data logs event logs maintenance logs min/max of instantaneous values time stamping |
Depth | 72 mm |
Device Application | gateway multi-tariff power monitoring WAGES metering |
Ethernet Service | SNMP-Traps SNTP client |
Frequency Measurement Range | 45-65 Hz |
Height | 96 mm |
Information Displayed | tariff (8) |
Market Segment | buildings large building cost management: billing: main incomer buildings large building cost management: billing: sub feeder buildings large building cost management: cost allocation: main incomer buildings large building cost management: cost allocation: sub feeder buildings large building network management: sub feeder buildings medium building cost management: billing: main incomer buildings medium building cost management: billing: sub feeder buildings medium building cost management: cost allocation: main incomer buildings medium building cost management: cost allocation: sub feeder buildings medium building network management: main incomer buildings medium building network management: sub feeder buildings multi-site cost management: billing: main incomer buildings multi-site cost management: billing: sub feeder buildings multi-site cost management: cost allocation: main incomer buildings multi-site cost management: cost allocation: sub feeder buildings multi-site network management: sub feeder buildings small building cost management: billing: main incomer buildings small building cost management: billing: sub feeder buildings small building cost management: cost allocation: main incomer buildings small building cost management: cost allocation: sub feeder buildings small building network management: main incomer buildings small building network management: sub feeder data center cost management: billing: main incomer data center cost management: billing: sub feeder data center cost management: cost allocation: main incomer data center cost management: cost allocation: sub feeder data center network management: sub feeder healthcare cost management: billing: main incomer healthcare cost management: billing: sub feeder healthcare cost management: cost allocation: main incomer healthcare cost management: cost allocation: sub feeder healthcare network management: sub feeder industry cost management: billing: main incomer industry cost management: billing: sub feeder industry cost management: cost allocation: main incomer industry cost management: cost allocation: sub feeder industry network management: sub feeder |
Maximum Power Consumption In VA | 10 VA at 480 V |
Measurement Current | 5-10000 mA |
Measurement Voltage | 20-400 V AC 45...65 Hz between phase and neutral 20-690 V AC 45...65 Hz between phases |
Metering Type | calculated ground current measured neutral current |
Mounting Mode | flush-mounted |
Net Weight | 450 g |
Network Frequency | 50 Hz 60 Hz |
Number Of Outputs | 2 digital |
Ride-through Time | 129 ms 230 V AC typical 35 ms 120 V AC typical |
Sampling Rate | 128 samples/cycle |
Web Services | alarm notification by e-mail diagnostic via predefined web pages real time viewing of data web server |
Width | 96 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -40-85 °C |
Electromagnetic Compatibility | conducted and radiated emissions class B conforming to EN 55022 conducted RF disturbances level 3 conforming to IEC 61000-4-6 electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 electrostatic discharge - test level: 8 kV level 4 conforming to IEC 61000-4-2 limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3 limits for harmonic current emissions class A conforming to IEC 61000-3-2 magnetic field at power frequency level 4 conforming to IEC 61000-4-8 radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 surge immunity test level 4 conforming to IEC 61000-4-5 voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
IP Degree Of Protection | IP30 body: conforming to IEC 60529 IP52 front: conforming to IEC 60529 |
Operating Altitude | 3000 m |
Pollution Degree | 2 |
Product Certifications | CE conforming to IEC 61010-1 cULus conforming to UL 61010-1 |
Relative Humidity | 5-95 % at 50-50 °C |
Standards | EN 50470-1 EN 50470-3 IEC 60529 IEC 61557-12 IEC 62053-22 IEC 62053-24 UL 61010-1 |
OTHER | |
Poles Description | 1P + N 3P 3P + N |
[Us] Rated Supply Voltage | 100...480 V AC 45...65 Hz 125...250 V DC |
Write Your Own Review