
LVR07250A40T - Anti Harmonic Detuned Reactor 25kvar 190Hz (3.8) 7% 50Hz 400V
Schneider
SKU
SE_LVR07250A40T
Model
LVR07250A40T
SGD $1,388.47 All prices inclusive of GST
Short description of LVR07250A40T
LVR07250A40T. DETUNED REACTOR 400V 50HZ 25KVAR 190HZ
Country of Origin
China
Anti Harmonic detuned reactor 25kvar 190Hz (3.8) 7% 50Hz 400V.
Label :  Detuned reactors
-  device short name :  DR
-  product or component type :  detuned reactor
-  network frequency :  50 Hz
-  reactive power rating :  25 kvarfor 400 V AC 50 Hz
-  network rated voltage :  400 V AC 50 Hz
-  tuning order :  3.8
-  190 Hz
-  7 %
-  50 Hz
-  Range Presentation :  Detuned reactors are specific three phase inductors dedicated to attenuating the amplification of harmonics on highly polluted networks and to protecting the different components of the installation.
They form a complete product range from 6 to 100 kvar and are available in the most common tunings like 135, 190 and 215 Hz for network voltage of 400/415V 50Hz. They must be chosen according to the capacitors they are associated with.
Technical data
-  anti-rust coating
-  thermal probe with no volt contact
-  Merlin Gerin label
-  standard :  IEC 60289, EN 60289
-  Range Benefits :  Simplicity : 
-  long service life improved by a wide range with the right sizing to fit all risk of harmonicsPeace of mind : 
-  safety operating mechanism provided by a thermal probe protection
-  product with dry type which needs minimum maintenance
-  Range Application Presentation : 
-  Power quality supplied :  limitation of pollution to the network.
Label :  Detuned reactors
-  device short name :  DR
-  product or component type :  detuned reactor
-  network frequency :  50 Hz
-  reactive power rating :  25 kvarfor 400 V AC 50 Hz
-  network rated voltage :  400 V AC 50 Hz
-  tuning order :  3.8
-  190 Hz
-  7 %
-  50 Hz
-  Range Presentation :  Detuned reactors are specific three phase inductors dedicated to attenuating the amplification of harmonics on highly polluted networks and to protecting the different components of the installation.
They form a complete product range from 6 to 100 kvar and are available in the most common tunings like 135, 190 and 215 Hz for network voltage of 400/415V 50Hz. They must be chosen according to the capacitors they are associated with.
Technical data
-  anti-rust coating
-  thermal probe with no volt contact
-  Merlin Gerin label
-  standard :  IEC 60289, EN 60289
-  Range Benefits :  Simplicity : 
-  long service life improved by a wide range with the right sizing to fit all risk of harmonicsPeace of mind : 
-  safety operating mechanism provided by a thermal probe protection
-  product with dry type which needs minimum maintenance
-  Range Application Presentation : 
-  Power quality supplied :  limitation of pollution to the network.
MAIN SPECIFICATIONS | |
---|---|
Product Or Component Type | detuned reactor |
Device Short Name | DR |
EAN13 | 3606480541483 |
Range | PowerLogic |
Range Name | SAH detuned reactors |
Reactive Power Rating | 25 kvar for 400 V AC 50 Hz |
Tuning Order | 3.8 - 190 Hz - 7 % - 50 Hz |
Value Of Inductance | 1.499 mH |
[Imp] Maximum Permanent Current | 1.2 x I1 |
COMPLEMENTARY | |
Connections - Terminals | pad terminal |
Depth | 160 mm |
Dynamic Withstand Current | 2.2 x Isc |
Electrical Insulation Class | class H |
Fixing Center | 200 x 125 mm |
Fundamental Current Rating | 36.1 A |
Harmonic Current Spectrum | 13.6 % x I7 3.7 % x I3 38.2 % x I5 4.9 % x I11 |
Height | 220 mm |
Inductance Tolerance | - 5 % to 5 % per phase |
Maximum Current Irms | 39 A |
Net Weight | 15 kg |
Network Frequency | 50 Hz |
Network Rated Voltage | 400 V AC 50 Hz |
Power Losses | 200 W |
Type Of Cooling | forced convection |
Type Of Installation | indoor installation |
Width | 240 mm |
[Ith] Conventional Free Air Thermal Current | 2 A at 250 V AC 50 Hz |
[Ui] Rated Insulation Voltage | 1.1 kV |
ENVIRONMENT | |
Ambient Air Temperature For Operation | 0-50 °C at > 1000...2000 m 0-55 °C at <= 1000 m |
Average Ambient Air Temperature For Operation | 35 °C at > 1000...2000 m (average over 1 year) 40 °C at <= 1000 m (average over 1 year) 45 °C at > 1000...2000 m (average over 24 hours) 50 °C at <= 1000 m (average over 24 hours) |
Climatic Withstand | relative humidity: 20...80 % salt mist (400 V/50 Hz) : 250 hours |
Dielectric Test Voltage | 4 kV 50 Hz 1 minute |
IP Degree Of Protection | IP00 |
Operating Altitude | <= 2000 m |
Standards | IEC 60068 |
OTHER | |
Poles Description | detuned reactor |
Write Your Own Review