Power Base, TeSys U, 3P, 12A/690V
Schneider
SKU
SE_LUB12
Model
LUB12
SGD $217.68
Short description of LUB12
SCREW CLAMP BASE 12A
Country of Origin
France
power base
-  TeSys U
-  12 A
-  screw clamps control.
Label :  TeSys U
-  range of product :  TeSys U
-  suitability for isolation :  yes
-  [Ith] conventional free air thermal current :  12 A
-  utilisation category :  AC
- 44,AC
- 43,AC
- 41
-  [Uc] control circuit voltage :  24 V AC 50/60 Hz, 24 V DC, 48 V AC 50/60 Hz, 48...72 V DC, 110...220 V DC, 110...240 V AC 50/60 Hz
-  range :  TeSys
-  product name :  TeSys U
-  device short name :  LUB
-  product or component type :  non reversing power base
-  device application :  motor
-  poles description :  3P
-  Range Presentation :  With a capacity of up to 32A/15 kW, TeSys U consists of : 
-  One 45 mm power base (1) :  2 ratings, reversing or non
- reversing, circuit-breaker function and built-in interference suppression
-  One clip-on control unit, from a choice of 3 :  Standard CU :  protection against overloads and short-circuits/Expandable CU :  + alarm and fault differentiation/ Multifunction CU (2) :  real time control of motor load, local or remote diagnostics and parameter setting
-  One clip-on automation control module, from a choice of 3 :  (3) :  Modbus, CANopen, AS
- Interface and PROFIBUS DP, Ethernet, DeviceNet, Fipio, Interbus S via Advantys STB le module or a simple parallel link
-  Two optional 45 mm power functions :  limiter
- isolator(4) and changeover relay (5)
-  Range Benefits :  A motor starter simple and compact
Introducing the 1st intelligent starter capable of integrating motor control, control and changeover functions in a unit 45 mm wide! Compact, simple and modular, it adapts to all the applications.
-  Range Application Presentation : 
-  Industry :  ideal solution when the motor starter needs to be decentralised in the machine or the process
-  TeSys U
-  12 A
-  screw clamps control.
Label :  TeSys U
-  range of product :  TeSys U
-  suitability for isolation :  yes
-  [Ith] conventional free air thermal current :  12 A
-  utilisation category :  AC
- 44,AC
- 43,AC
- 41
-  [Uc] control circuit voltage :  24 V AC 50/60 Hz, 24 V DC, 48 V AC 50/60 Hz, 48...72 V DC, 110...220 V DC, 110...240 V AC 50/60 Hz
-  range :  TeSys
-  product name :  TeSys U
-  device short name :  LUB
-  product or component type :  non reversing power base
-  device application :  motor
-  poles description :  3P
-  Range Presentation :  With a capacity of up to 32A/15 kW, TeSys U consists of : 
-  One 45 mm power base (1) :  2 ratings, reversing or non
- reversing, circuit-breaker function and built-in interference suppression
-  One clip-on control unit, from a choice of 3 :  Standard CU :  protection against overloads and short-circuits/Expandable CU :  + alarm and fault differentiation/ Multifunction CU (2) :  real time control of motor load, local or remote diagnostics and parameter setting
-  One clip-on automation control module, from a choice of 3 :  (3) :  Modbus, CANopen, AS
- Interface and PROFIBUS DP, Ethernet, DeviceNet, Fipio, Interbus S via Advantys STB le module or a simple parallel link
-  Two optional 45 mm power functions :  limiter
- isolator(4) and changeover relay (5)
-  Range Benefits :  A motor starter simple and compact
Introducing the 1st intelligent starter capable of integrating motor control, control and changeover functions in a unit 45 mm wide! Compact, simple and modular, it adapts to all the applications.
-  Range Application Presentation : 
-  Industry :  ideal solution when the motor starter needs to be decentralised in the machine or the process
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity Code | 10 kA at 500 V 4 kA at 690 V 50 kA at 230 V 50 kA at 440 V |
Control Type | 3P |
Product Or Component Type | non reversing power base |
Range Of Product | TeSys U |
[Ie] Rated Operational Current | 12 A at <= 440 V 12 A at 500 V 9 A at 690 V |
[Uc] Control Circuit Voltage | 110...220 V DC 110...240 V AC 50/60 Hz 24 V AC 50/60 Hz 24 V DC 48...72 V AC 50/60 Hz 48...72 V DC |
[Ue] Rated Operational Voltage | 690 V AC for power circuit |
Device Short Name | LUB |
EAN13 | 3389110362770 |
Range | TeSys |
Range Name | TeSys U |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Suitability For Isolation | yes |
Utilisation Category | AC-41 AC-43 AC-44 |
COMPLEMENTARY | |
Communication Network Type | 690 V AC for power circuit |
Product Name | TeSys U |
[Ics] Rated Service Breaking Capacity | 10 kA at 500 V 4 kA at 690 V 50 kA at 230 V 50 kA at 440 V |
Auxiliary Contact Composition | 1 NO + 1 NC |
Auxiliary Contacts Type | type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1 |
Compatibility Code | LUB |
Connections - Terminals | control circuit: screw clamp terminals 1 cable(s) 0.34-1.5 mm² flexible with cable end control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² flexible without cable end control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² rigid control circuit: screw clamp terminals 2 cable(s) 0.34-1.5 mm² flexible with cable end control circuit: screw clamp terminals 2 cable(s) 0.75-1.5 mm² flexible without cable end control circuit: screw clamp terminals 2 cable(s) 0.75-1.5 mm² rigid power circuit: screw clamp terminals 1 cable(s) 1-10 mm² rigid power circuit: screw clamp terminals 1 cable(s) 1-6 mm² flexible with cable end power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm² flexible without cable end power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end power circuit: screw clamp terminals 2 cable(s) 1-6 mm² flexible with cable end power circuit: screw clamp terminals 2 cable(s) 1-6 mm² rigid |
Depth | 126 mm |
Device Application | motor control motor protection |
Fixing Mode | clipped (DIN rail) screw-fixed (plate) |
Height | 154 mm |
Immunity To Microbreaks | 3 ms for control circuit |
Maximum Operating Rate | 3600 cyc/h |
Mechanical Durability | 15 Mcycles |
Net Weight | 0.9 kg |
Network Frequency | 40...60 Hz |
Operating Time | 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit 50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit 75 ms closing with LUCM for control circuit |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N |
Tightening Torque | control circuit: 0.8-1.2 N.m flat screwdriver 5 mm control circuit: 0.8-1.2 N.m Philips no 1 screwdriver 5 mm power circuit: 1.9-2.5 N.m flat screwdriver 6 mm power circuit: 1.9-2.5 N.m Philips No 2 screwdriver 6 mm |
Typical Current Consumption | 130 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 140 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 150 mA at 24 V DC I maximum while closing with LUCM 280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD 280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD 35 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 35 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD 35 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD 35 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 60 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD 70 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD 70 mA at 24 V DC I rms sealed with LUCM |
Width | 45 mm |
[Ith] Conventional Free Air Thermal Current | 12 A |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947-6-2 |
[Ui] Rated Insulation Voltage | 600 V conforming to CSA C22.2 No 60947-4-1 600 V conforming to UL 60947-4-1 690 V conforming to IEC 60947-6-2 (pollution degree 3) |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-60 °C with LUCM -25-70 °C with LUCA, LUCB, LUCC, LUCD |
Ambient Air Temperature For Storage | -40-85 °C |
Fire Resistance | 650 °C conforming to IEC 60695-2-12 960 °C parts supporting live components conforming to IEC 60695-2-12 |
Heat Dissipation | 1.7-1.7 W for control circuit with LUCM 2-2 W for control circuit with LUCA, LUCB, LUCC, LUCD |
Immunity To Radioelectric Fields | 10 V conforming to IEC 61000-4-6 |
Immunity To Voltage Dips | 70 % / 500 ms conforming to IEC 61000-4-11 |
IP Degree Of Protection | IP20 conforming to IEC 60947-1 (front panel and wired terminals) IP20 conforming to IEC 60947-1 (other faces) IP40 conforming to IEC 60947-1 (front panel outside connection zone) |
Non-dissipating Shock Wave | 1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2 1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2 2 kV common mode 24...240 V AC conforming to IEC 60947-6-2 2 kV common mode 48...220 V DC conforming to IEC 60947-6-2 |
Operating Altitude | 2000 m |
Product Certifications | ASEFA ATEX CCC CE CSA EAC Marine UL |
Protective Treatment | TH conforming to IEC 60068 |
Resistance To Electrostatic Discharge | 8 kV level 3 in open air conforming to IEC 61000-4-2 8 kV level 4 on contact conforming to IEC 61000-4-2 |
Resistance To Fast Transients | 2 kV class 3 serial link conforming to IEC 61000-4-4 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
Resistance To Radiated Fields | 10 V/m 3 conforming to IEC 61000-4-3 |
Shock Resistance | 10 gn power poles open conforming to IEC 60068-2-27 15 gn power poles closed conforming to IEC 60068-2-27 |
Standards | CSA C22.2 No 60947-4-1, with phase barrier EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier |
Vibration Resistance | 2 gn (f= 5-300 Hz) power poles open conforming to IEC 60068-2-27 4 gn (f= 5-300 Hz) power poles closed conforming to IEC 60068-2-27 |
OTHER | |
Poles Description | 3P |
[Us] Rated Supply Voltage | TeSys U |
Write Your Own Review