Reversing Power Base, TeSys U, 3P, 32A/690V, Coil 24V DC.

Schneider
SKU
SE_LU2B32BL
Model
LU2B32BL
SGD $1,184.08

Short description of LU2B32BL

All-in-one motor starters up to 38 A (18.5 kW / 400 V)
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 13 To 15 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
range : TeSys
-  product name : TeSys U
-  device short name : LU2B
-  product or component type : Reversing power base
-  device application : Motor controlMotor protection
-  product compatibility : Control unit LUC.X6BLControl unit LUC.1XBLControl unit LUC.05BLControl unit LUC.12BLControl unit LUC.18BLControl unit LUC.32BL
-  poles description : 3P
-  suitability for isolation : Yes
-  [Ue] rated operational voltage : 690 V AC for power circuit
-  network frequency : 40...60 Hz
-  [Ith] conventional free air thermal current : 32 A
-  [Ie] rated operational current : 28.5 A at - utilisation category : AC
- 43AC
- 44AC
- 41
-  [Ics] rated service breaking capacity : 50 kA at 230 V50 kA at 440 V10 kA at 500 V4 kA at 690 V
-  auxiliary contact composition : 1 NO + 1 NC
-  auxiliary contacts type : type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1
-  [Uc] control circuit voltage : 24 V DC
-  control circuit voltage limits : 14.5 V DC drop
- out20...27 V DC in operation
MAIN SPECIFICATIONS
Breaking Capacity Code10 kA at 500 V
4 kA at 690 V
50 kA at 230 V
50 kA at 440 V
Control Type3P
Product Or Component Typereversing power base
Range Of ProductTeSys U
[Ie] Rated Operational Current21 A at 690 V
23 A at 500 V
28.5 A at <= 440 V
[Uc] Control Circuit Voltage24 V DC
[Ue] Rated Operational Voltage690 V AC for power circuit
Device Short NameLU2B
RangeTeSys
Range NameTeSys U
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Suitability For Isolationyes
Utilisation CategoryAC-41
AC-43
AC-44
COMPLEMENTARY
Communication Network Type690 V AC for power circuit
Product NameTeSys U
[Ics] Rated Service Breaking Capacity10 kA at 500 V
4 kA at 690 V
50 kA at 230 V
50 kA at 440 V
Auxiliary Contact Composition1 NO + 1 NC
Auxiliary Contacts Type type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1
type mirror contact (1 NC) conforming to IEC 60947-1
Compatibility CodeLU2B
Connections - Terminalscontrol circuit: screw clamp terminals 1 cable(s) 0.34-1.5 mm² flexible with cable end
control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² flexible without cable end
control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² rigid
control circuit: screw clamp terminals 2 cable(s) 0.34-1.5 mm² flexible with cable end
control circuit: screw clamp terminals 2 cable(s) 0.75-1.5 mm² flexible without cable end
control circuit: screw clamp terminals 2 cable(s) 0.75-1.5 mm² rigid
power circuit: screw clamp terminals 1 cable(s) 1-10 mm² rigid
power circuit: screw clamp terminals 1 cable(s) 1-6 mm² flexible with cable end
power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm² flexible without cable end
power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end
power circuit: screw clamp terminals 2 cable(s) 1-6 mm² flexible with cable end
power circuit: screw clamp terminals 2 cable(s) 1-6 mm² rigid
Control Circuit Voltage Limits14.5 V DC drop-out
20...27 V DC in operation
Depth126 mm
Device Applicationmotor control
motor protection
Fixing Modeclipped (DIN rail)
screw-fixed (plate)
Height224 mm
Immunity To Microbreaks3 ms for control circuit
Inrush Restraint Duration15 ms DC
Maximum Operating Rate3600 cyc/h
Mechanical Durability15 Mcycles
Net Weight1.27 kg
Network Frequency40...60 Hz
Operating Time150 ms with change of direction for power circuit
35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit
70 ms closing with LUCA, LUCB, LUCC, LUCD for control circuit
75 ms closing with LUCM for control circuit
75 ms without change of direction for power circuit
Product Compatibilitycontrol unit LUC.05BL
control unit LUC.12BL
control unit LUC.18BL
control unit LUC.1XBL
control unit LUC.32BL
control unit LUC.X6BL
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Tightening Torquecontrol circuit: 0.8-1.2 N.m flat screwdriver 5 mm
control circuit: 0.8-1.2 N.m Philips no 1 screwdriver 5 mm
power circuit: 1.9-2.5 N.m flat screwdriver 6 mm
power circuit: 1.9-2.5 N.m Philips No 2 screwdriver 6 mm
Typical Current Consumption120 mA at 24 V DC I maximum while closing
120 mA at 24 V DC I rms sealed
Width45 mm
[Ith] Conventional Free Air Thermal Current32 A
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947-6-2
[Ui] Rated Insulation Voltage600 V conforming to CSA C22.2 No 60947-4-1
600 V conforming to UL 60947-4-1
690 V conforming to IEC 60947-6-2 (pollution degree 3)
ENVIRONMENT
Ambient Air Temperature For Operation-25-60 °C with LUCM
-25-70 °C with LUCA, LUCB, LUCC, LUCD
Ambient Air Temperature For Storage-40-85 °C
Fire Resistance650 °C conforming to IEC 60695-2-12
960 °C parts supporting live components conforming to IEC 60695-2-12
Heat Dissipation1.8-1.8 W for control circuit with LUCM
3-3 W for control circuit with LUCA, LUCB, LUCC, LUCD
Immunity To Radioelectric Fields10 V conforming to IEC 61000-4-6
Immunity To Voltage Dips70 % / 500 ms conforming to IEC 61000-4-11
IP Degree Of ProtectionIP20 conforming to IEC 60947-1 (front panel and wired terminals)
IP20 conforming to IEC 60947-1 (other faces)
IP40 conforming to IEC 60947-1 (front panel outside connection zone)
Operating Altitude2000 m
Product CertificationsASEFA
ATEX
CCC
CE
CSA
EAC
Marine
UL
Protective TreatmentTH conforming to IEC 60068
Resistance To Electrostatic Discharge8 kV level 3 in open air conforming to IEC 61000-4-2
8 kV level 4 on contact conforming to IEC 61000-4-2
Resistance To Fast Transients2 kV class 3 serial link conforming to IEC 61000-4-4
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Resistance To Radiated Fields10 V/m 3 conforming to IEC 61000-4-3
Shock Resistance10 gn power poles open conforming to IEC 60068-2-27
15 gn power poles closed conforming to IEC 60068-2-27
StandardsCSA C22.2 No 60947-4-1, with phase barrier
EN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
Vibration Resistance2 gn (f= 5-300 Hz) power poles open conforming to IEC 60068-2-27
4 gn (f= 5-300 Hz) power poles closed conforming to IEC 60068-2-27
OTHER
Poles Description3P
[Us] Rated Supply VoltageTeSys U
Write Your Own Review
You're reviewing:Reversing Power Base, TeSys U, 3P, 32A/690V, Coil 24V DC.
Your Rating