Thermal Overload Relay, TeSys LRD, 12...18 A, Class 10A

Schneider
SKU
SE_LRD21
Model
LRD21
Special Price SGD $25.46 Regular Price SGD $31.65

Short description of LRD21

TESYS D THERMAL OVERLOAD 12-18A CL10A CTR Promo
Country of Origin
Thailand
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
TeSys LRD thermal overload relays
-  12...18 A
-  class 10A.
Label :  TeSys LRD
-  range :  TeSys
-  thermal protection adjustment range :  12-18 A
-  [Ui] rated insulation voltage :  600 V power circuit conforming to CSA, 600 V power circuit conforming to UL, 690 V power circuit conforming to IEC 60947-4-1
-  product name :  TeSys LRD
-  product or component type :  differential thermal overload relay
-  device short name :  LRD
-  relay application :  motor protection
-  product compatibility :  LC1D32,LC1D18,LC1D25,LC1D38
-  network type :  AC,DC
-  Range Presentation : 

-  Manual and automatic reset
-  Sealable flap
-  Prewiring kit
-  Terminal block for separate mounting
-  Remote electrical reset
-  Can be combined with TeSys model d contactors in a 45 mm wide space up to 18.5 kW, 55 mm from 15 to 30 kW
-  Connectors :  spring terminal, screw clamp, terminal block EverLink (LRD3)
-  Class 10 A & class 20.
-  Range Benefits :  Safe and effective protectionWith its integrated manual
- automatic reset and simple installation in screw clamp terminals, by spring terminal, by ring terminals and by EverLink terminals version, model LRD thermal overload relays are very reliable and cover the whole range of motor ratings up to 150 A. They can be combined with TeSys d contactors to form an extremely compact starter.
-  Range Application Presentation :  Industry, infrastructure, building, etc. : 

-  Standard motor protection
-  Line protection
-  Protection :  motor overload, stalling, loss of phase
MAIN SPECIFICATIONS
Control Typeblue push-button: reset
red push-button: stop
Product Or Component Typedifferential thermal overload relay
[Ie] Rated Operational Currentblue push-button: reset
red push-button: stop
[Ue] Rated Operational Voltage690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
Device Short NameLRD
EAN133389110346831
Mounting Supportplate, with specific accessories
rail, with specific accessories
under contactor
Network TypeAC
DC
RangeTeSys
TeSys Deca
Range NameTeSys LRD
Relay Applicationmotor protection
Thermal Overload Classclass 10A conforming to IEC 60947-4-1
COMPLEMENTARY
Communication Network Type690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
Product NameTeSys Deca
TeSys LRD
Associated Fuse Rating4 A BS for signalling circuit
4 A gG for signalling circuit
Auxiliary Contact Composition1 NO + 1 NC
Compatibility CodeLRD
Connections - Terminalscontrol circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² flexible with cable end
control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² flexible without cable end
control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm² solid
power circuit: screw clamp terminals 1 cable(s) 1.5-10 mm² flexible without cable end
power circuit: screw clamp terminals 1 cable(s) 1-4 mm² flexible with cable end
power circuit: screw clamp terminals 1 cable(s) 1-6 mm² solid
Depth70 mm
Flame RetardanceV1 conforming to UL 94
Height66 mm
Mechanical Robustnessshocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
vibrations: 6 Gn conforming to IEC 60068-2-6
Net Weight0.124 kg
Network Frequency0...400 Hz
Permissible Current0.1 A at 250 V DC-13 for signalling circuit
1.5 A at 240 V AC-15 for signalling circuit
Phase Failure Sensitivitytripping current 130 % of Ir on two phase, the last one at 0
Product CompatibilityLC1D18
LC1D25
LC1D32
LC1D38
Temperature Compensation-20-60 °C
Thermal Protection Adjustment Range12-18 A
Tightening Torquecontrol circuit: 1.7 N.m - on screw clamp terminals
power circuit: 2.5 N.m - on screw clamp terminals
Tripping Threshold1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Width45 mm
[Ith] Conventional Free Air Thermal Current5 A for signalling circuit
[Uimp] Rated Impulse Withstand Voltage6 kV
[Ui] Rated Insulation Voltagepower circuit: 600 V conforming to CSA
power circuit: 600 V conforming to UL
power circuit: 690 V conforming to IEC 60947-4-1
ENVIRONMENT
Ambient Air Temperature For Operation-20-60 °C without derating conforming to IEC 60947-4-1
Ambient Air Temperature For Storage-60-70 °C
Dielectric Strength1.89 kV at 50 Hz conforming to IEC 60947-1
IP Degree Of ProtectionIP20 conforming to IEC 60529
Product CertificationsATEX INERIS
BV
CCC
CSA
DNV-GL
EAC
IEC
LROS (Lloyds register of shipping)
RINA
UKCA
UL
Protective TreatmentTH conforming to IEC 60068
StandardsCSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
EN 50495
EN/IEC 60947-4-1
EN/IEC 60947-5-1
GB/T 14048.4
GB/T 14048.5
UL 60947-4-1
UL 60947-5-1
OTHER
Poles Descriptiondifferential thermal overload relay