LR2K0314 - TeSys K - Differential Thermal Overload Relays - 5.5...8 A - Class 10A
Schneider
SKU
SE_LR2K0314
Model
LR2K0314
SGD $50.82 All prices inclusive of GST
Short description of LR2K0314
LR2K0314. TESYS K OVERLOAD RELAY CL10 5.5 - 8A
Country of Origin
Czechia
TeSys K
-  differential thermal overload relays
-  5.5...8 A
-  class 10A.
Label :  TeSys LR2 k
-  range of product :  TeSys K thermal overload relays
-  thermal overload class :  class 10A conforming to IEC 60947-4-1
-  thermal protection adjustment range :  5.5-8 A
-  range :  TeSys
-  product name :  TeSys LRK
-  [Ui] rated insulation voltage :  690 V power circuit conforming to BS 4941, 690 V power circuit conforming to IEC 60947, 750 V power circuit conforming to VDE 0110 group C, 600 V power circuit conforming to CSA C22.2 No 14
-  product or component type :  differential thermal overload relay
-  device short name :  LR2K
-  relay application :  motor protection
-  product compatibility :  LC7K,LC1K,LP4K,LP1K
-  network type :  DC,AC
-  Range Presentation : 
-  Manual and automatic reset
-  Sealable flap
-  Prewiring kit
-  Terminal block for separate mounting
-  Remote electrical reset
-  Can be combined with TeSys k contactors in a 45 mm wide space
-  Connectors :  spring terminal, screw clamp
-  Class 10 A.
-  Range Benefits :  Safe and effective protectionWith its integrated manual
- automatic reset and simple installation, model LR2 k thermal overload relays are very reliable and cover the whole range of motor ratings up to 16 A. They can be combined with TeSys k contactors to form an extremely compact starter.
-  Range Application Presentation : 
-  Industry, infrastructure, building, etc : 
-  Standard motor protection
-  Line protection
-  Protection :  motor overload, stalling, loss of phase
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  differential thermal overload relays
-  5.5...8 A
-  class 10A.
Label :  TeSys LR2 k
-  range of product :  TeSys K thermal overload relays
-  thermal overload class :  class 10A conforming to IEC 60947-4-1
-  thermal protection adjustment range :  5.5-8 A
-  range :  TeSys
-  product name :  TeSys LRK
-  [Ui] rated insulation voltage :  690 V power circuit conforming to BS 4941, 690 V power circuit conforming to IEC 60947, 750 V power circuit conforming to VDE 0110 group C, 600 V power circuit conforming to CSA C22.2 No 14
-  product or component type :  differential thermal overload relay
-  device short name :  LR2K
-  relay application :  motor protection
-  product compatibility :  LC7K,LC1K,LP4K,LP1K
-  network type :  DC,AC
-  Range Presentation : 
-  Manual and automatic reset
-  Sealable flap
-  Prewiring kit
-  Terminal block for separate mounting
-  Remote electrical reset
-  Can be combined with TeSys k contactors in a 45 mm wide space
-  Connectors :  spring terminal, screw clamp
-  Class 10 A.
-  Range Benefits :  Safe and effective protectionWith its integrated manual
- automatic reset and simple installation, model LR2 k thermal overload relays are very reliable and cover the whole range of motor ratings up to 16 A. They can be combined with TeSys k contactors to form an extremely compact starter.
-  Range Application Presentation : 
-  Industry, infrastructure, building, etc : 
-  Standard motor protection
-  Line protection
-  Protection :  motor overload, stalling, loss of phase
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Control Type | selector switch: manual or automatic reset blue push-button: stop and manual reset red push-button: trip test function |
Product Or Component Type | differential thermal overload relay |
Range Of Product | TeSys K thermal overload relays |
[Ie] Rated Operational Current | selector switch: manual or automatic reset blue push-button: stop and manual reset red push-button: trip test function |
[Ue] Rated Operational Voltage | <= 690 V for power circuit 250 V DC DC-13 for signalling circuit 690 V AC AC-15 for signalling circuit |
Device Short Name | LR2K |
EAN13 | 3389110230574 |
Mounting Support | plate, with specific accessories rail, with specific accessories under contactor |
Network Type | AC DC |
Power Dissipation Per Pole | 2 W |
Range | TeSys |
Range Name | TeSys LR2 K |
Relay Application | motor protection |
Thermal Overload Class | class 10A conforming to IEC 60947-4-1 |
COMPLEMENTARY | |
Communication Network Type | <= 690 V for power circuit 250 V DC DC-13 for signalling circuit 690 V AC AC-15 for signalling circuit |
Product Name | TeSys LRK |
Associated Fuse Rating | 6 A gG for signalling circuit conforming to IEC 60947 6 A gG for signalling circuit conforming to VDE 0660 |
Auxiliary Contact Composition | 1 NO + 1 NC |
Compatibility Code | LR2K |
Connections - Terminals | screw clamp terminals 1 cable(s) 0.34-2.5 mm²flexible with cable end screw clamp terminals 1 cable(s) 0.75-4 mm²flexible without cable end screw clamp terminals 1 cable(s) 1.5-4 mm²solid screw clamp terminals 2 cable(s) 0.34-1.5 mm²flexible with cable end screw clamp terminals 2 cable(s) 0.75-4 mm²flexible without cable end screw clamp terminals 2 cable(s) 1.5-4 mm²solid |
Depth | 65 mm |
Flame Retardance | requirement 2 conforming to NF F 16-101 requirement 2 conforming to NF F 16-102 V1 conforming to UL 94 |
Height | 58 mm |
Local Signalling | trip indicator (yellow) |
Mechanical Robustness | shocks NC contact: 10 Gn for 11 ms conforming to IEC 60068-2-27 shocks NO contact: 10 Gn for 11 ms conforming to IEC 60068-2-27 vibrations NC contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 vibrations NO contact: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
Net Weight | 0.145 kg |
Network Frequency | <= 400 Hz |
Phase Failure Sensitivity | yes conforming to IEC 60947-4-1 |
Product Compatibility | LC1K LC7K LP1K LP4K |
Thermal Protection Adjustment Range | 5.5-8 A |
Tightening Torque | 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 |
Width | 45 mm |
[Ith] Conventional Free Air Thermal Current | 6 A for signalling circuit |
[Uimp] Rated Impulse Withstand Voltage | 6 kV |
[Ui] Rated Insulation Voltage | power circuit: 600 V conforming to CSA C22.2 No 14 power circuit: 690 V conforming to BS 4941 power circuit: 690 V conforming to IEC 60947 power circuit: 750 V conforming to VDE 0110 group C |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -20-55 °C without derating conforming to IEC 60947 -30-60 °C with derating conforming to IEC 60947 |
Ambient Air Temperature For Storage | -40-70 °C |
Fire Resistance | 850 °C conforming to IEC 60695-2-1 |
IP Degree Of Protection | IP2x conforming to IEC 60529 |
Operating Altitude | 2000 m without derating |
Product Certifications | CSA UL |
Protective Treatment | TC conforming to DIN 50016 TC conforming to IEC 60068 |
Standards | BS 4941 IEC 60947 NF C 63-650 VDE 0660 |
OTHER | |
Poles Description | differential thermal overload relay |
[Us] Rated Supply Voltage | TeSys K thermal overload relays |