Loading...
*All information are subjected to changes without prior notice.

LC1F500FE7 - TeSys F Contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - Coil 115 V AC.

Schneider
SKU
SE_LC1F500FE7
Model
LC1F500FE7

Obsolete

All prices inclusive of GST

Short description of LC1F500FE7

LC1F500FE7. Contactors to control motors up to 1000 A (500 kW / 440 V)
Obsolete
range : TeSys
-  product name : TeSys F
-  product or component type : Contactor
-  device short name : LC1F
-  contactor application : Motor controlResistive load
-  utilisation category : AC
- 1AC
- 4AC
- 3
-  poles description : 3P
-  power pole contact composition : 3 NO
-  [Ue] rated operational voltage-  [Ie] rated operational current : 700 A (at - motor power kW : 250 kW at 380...400 V AC 50/60 Hz (AC
- 3)280 kW at 415 V AC 50/60 Hz (AC
- 3)295 kW at 440 V AC 50/60 Hz (AC
- 3)355 kW at 500 V AC 50/60 Hz (AC
- 3)335 kW at 660...690 V AC 50/60 Hz (AC
- 3)335 kW at 1000 V AC 50/60 Hz (AC
- 3)147 kW at 220...230 V AC 50/60 Hz (AC
- 3)80 kW at 400 V AC 50/60 Hz (AC
- 4)
-  [Uc] control circuit voltage : 115 V AC 40...400 Hz
MAIN SPECIFICATIONS
Control Type3P
Product Or Component Typecontactor
Range Of ProductTeSys F
[Ie] Rated Operational Current500 A (at <55 °C) at <= 440 V AC AC-3
700 A (at <40 °C) at <= 440 V AC AC-1
[Uc] Control Circuit Voltage115 V AC 40...400 Hz
[Ue] Rated Operational Voltage500 A (at <55 °C) at <= 440 V AC AC-3
700 A (at <40 °C) at <= 440 V AC AC-1
Average Impedance0.18 mOhm - Ith 700 A 50 Hz
Contactor Applicationmotor control
resistive load
Control Circuit TypeAC at 40...400 Hz
Device Short NameLC1F
Mounting Supportplate
Pole Contact Composition3 NO
Power Dissipation Per Pole45 W AC-3
88 W AC-1
RangeTeSys
Range NameTeSys F
Utilisation CategoryAC-1
AC-3
AC-4
COMPLEMENTARY
Product NameTeSys F
Associated Fuse Rating500 A aM at <= 440 V
800 A gG at <= 440 V
Compatibility CodeLC1F
Connections - Terminalscontrol circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
power circuit: bar 2 cable(s) - busbar cross section: 40 x 5 mm
power circuit: bolted connection
power circuit: lugs-ring terminals 2 cable(s) 240-240 mm²
Contactor Coil Voltage115 V AC standard
Control Circuit Voltage Limitsdrop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C)
operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Depth232 mm
Height238 mm
Hold-in Power Consumption In VA18-18 VA 40...400 Hz cos phi 0.9 (at 20 °C)
Inrush Power In VA1100-1100 VA 40...400 Hz cos phi 0.9 (at 20 °C)
Maximum Operating Rate2400 cyc/h 55 °C
Mechanical Durability10 Mcycles
Motor Power KW147 kW at 220...230 V AC 50/60 Hz (AC-3)
250 kW at 380...400 V AC 50/60 Hz (AC-3)
280 kW at 415 V AC 50/60 Hz (AC-3)
295 kW at 440 V AC 50/60 Hz (AC-3)
335 kW at 1000 V AC 50/60 Hz (AC-3)
335 kW at 660...690 V AC 50/60 Hz (AC-3)
355 kW at 500 V AC 50/60 Hz (AC-3)
80 kW at 400 V AC 50/60 Hz (AC-4)
Motor Starter Typedirect on-line contactor
Net Weight11.35 kg
Operating Time100...170 ms opening
40...65 ms closing
Power Range110-220 kW at 200-240 V 3 phases
110-220 kW at 380-440 V 3 phases
250-500 kW at 380-440 V 3 phases
250-500 kW at 480-500 V 3 phases
Rated Breaking Capacity4000 A conforming to IEC 60947-4-1
Tightening Torquecontrol circuit: 1.2 N.m
power circuit: 35 N.m
Width233 mm
[Icw] Rated Short-time Withstand Current1200 A 40 °C - 10 min
1500 A 40 °C - 3 min
2400 A 40 °C - 1 min
3200 A 40 °C - 30 s
4200 A 40 °C - 10 s
[Ith] Conventional Free Air Thermal Current700 A (at 40 °C)
[Uimp] Rated Impulse Withstand Voltage8 kV
[Ui] Rated Insulation Voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
ENVIRONMENT
Ambient Air Temperature For Operation-5-55 °C
Ambient Air Temperature For Storage-60-80 °C
Heat Dissipation18-18 W
IP Degree Of ProtectionIP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
Operating Altitude3000 m without derating
Overvoltage CategoryIII
Permissible Ambient Air Temperature Around The Device-40-70 °C
Product CertificationsABS
BV
CB
CSA
DNV
LROS (Lloyds register of shipping)
RINA
RMRoS
UKCA
UL
Protective TreatmentTH
StandardsEN 60947-1
EN 60947-4-1
IEC 60947-1
IEC 60947-4-1
JIS C8201-4-1
OTHER
Poles Description3P
[Us] Rated Supply VoltageTeSys F