Loading...

LC1D09P7 TeSys D Contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A

Schneider
SKU
SE_LC1D09P7
Model
LC1D09P7
Special Price SGD $22.48 Regular Price SGD $27.95 All prices inclusive of GST

Short description of LC1D09P7

Contactors to control motors up to 150 A (75 kW / 400 V) CTR Promo

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). It provides a 230V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Country of Origin
India
-
+

UOM: Piece

In stock
In Stock 24
Backorder Leadtime: 7 To 9 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
range : TeSys
-  product name : TeSys D
-  product or component type : Contactor
-  device short name : LC1D
-  contactor application : Resistive loadMotor control
-  utilisation category : AC
- 4AC
- 1AC
- 3
-  poles description : 3P
-  power pole contact composition : 3 NO
-  [Ue] rated operational voltage : Power circuit-  [Ie] rated operational current : 9 A (at - motor power kW : 2.2 kW at 220...230 V AC 50/60 Hz (AC
- 3)4 kW at 380...400 V AC 50/60 Hz (AC
- 3)4 kW at 415...440 V AC 50/60 Hz (AC
- 3)5.5 kW at 500 V AC 50/60 Hz (AC
- 3)5.5 kW at 660...690 V AC 50/60 Hz (AC
- 3)2.2 kW at 400 V AC 50/60 Hz (AC
- 4)
-  motor power HP (UL / CSA) : 1 hp at 230/240 V AC 50/60 Hz for 1 phase motors2 hp at 200/208 V AC 50/60 Hz for 3 phases motors2 hp at 230/240 V AC 50/60 Hz for 3 phases motors5 hp at 460/480 V AC 50/60 Hz for 3 phases motors7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
-  control circuit type : AC at 50/60 Hz
-  [Uc] control circuit voltage : 230 V AC 50/60 Hz
-  auxiliary contact composition : 1 NO + 1 NC
-  [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947
-  overvoltage category : III
-  [Ith] conventional free air thermal current : 25 A (at 60 °C) for power circuit10 A (at 60 °C) for signalling circuit
-  Irms rated making capacity : 250 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1
-  rated breaking capacity : 250 A at 440 V for power circuit conforming to IEC 60947
-  [Icw] rated short
- time withstand current : 105 A 40 °C
-  10 s for power circuit210 A 40 °C
-  1 s for power circuit30 A 40 °C
-  10 min for power circuit61 A 40 °C
-  1 min for power circuit100 A
-  1 s for signalling circuit120 A
-  500 ms for signalling circuit140 A
-  100 ms for signalling circuit
-  associated fuse rating : 10 A gG for signalling circuit conforming to IEC 60947-5-125 A gG at - average impedance : 2.5 mOhm
-  Ith 25 A 50 Hz for power circuit
-  [Ui] rated insulation voltage : Power circuit :  690 V conforming to IEC 60947-4-1Power circuit :  600 V CSA certifiedPower circuit :  600 V UL certifiedSignalling circuit :  690 V conforming to IEC 60947-1Signalling circuit :  600 V CSA certifiedSignalling circuit :  600 V UL certified
-  electrical durability : 0.6 Mcycles 25 A AC
- 1 at Ue
-  power dissipation per pole : 1.56 W AC
- 10.2 W AC
- 3
-  Front cover : With
-  mounting support : RailPlate
-  standards : CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
-  product certifications : GOSTBVLROS (Lloyds register of shipping)DNVCSARINACCCULGL
-  connections
-  terminals : Power circuit :  screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endPower circuit :  screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endPower circuit :  screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endPower circuit :  screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endPower circuit :  screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endPower circuit :  screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endControl circuit :  screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable endControl circuit :  screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable endControl circuit :  screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable endControl circuit :  screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable endControl circuit :  screw clamp terminals 1 cable(s) 1…4 mm²solid without cable endControl circuit :  screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
-  tightening torque : Power circuit :  1.7 N.m
-  on screw clamp terminals
-  with screwdriver flat Ø 6 mmPower circuit :  1.7 N.m
-  on screw clamp terminals
-  with screwdriver Philips No 2Control circuit :  1.7 N.m
-  on screw clamp terminals
-  with screwdriver flat Ø 6 mmControl circuit :  1.7 N.m
-  on screw clamp terminals
-  with screwdriver Philips No 2
-  operating time : 12...22 ms closing4...19 ms opening
-  safety reliability level : B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
-  mechanical durability : 15 Mcycles
-  maximum operating rate : 3600 cyc/h 60 °C

This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS
Control Type3P
Product Or Component Typecontactor
Range Of ProductTeSys D
TeSys Deca
[Ie] Rated Operational Current25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] Control Circuit Voltage230 V AC 50/60 Hz
[Ue] Rated Operational Voltagepower circuit: <= 300 V DC
power circuit: <= 690 V AC 25...400 Hz
Average Impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Contactor Applicationmotor control
resistive load
Control Circuit TypeAC at 50/60 Hz
Device Short NameLC1D
Motor Power Hp0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
1 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 200/208 V AC 50/60 Hz for 3 phases motors
2 hp at 230/240 V AC 50/60 Hz for 3 phases motors
5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
7.5 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Mounting Supportplate
rail
Pole Contact Composition3 NO
Power Dissipation Per Pole0.2 W AC-3
0.2 W AC-3e
1.56 W AC-1
Protective Coverwith
RangeTeSys
TeSys Deca
Range NameTeSys D
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Utilisation CategoryAC-1
AC-3
AC-3e
AC-4
COMPLEMENTARY
Communication Network Typepower circuit: <= 300 V DC
power circuit: <= 690 V AC 25...400 Hz
Product NameTeSys D
TeSys Deca
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1
20 A gG at <= 690 V coordination type 2 for power circuit
25 A gG at <= 690 V coordination type 1 for power circuit
Auxiliary Contact Composition1 NO + 1 NC
Auxiliary Contacts Type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Coil Technologywithout built-in suppressor module
Compatibility CodeLC1D
Connections - Terminalscontrol circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end
power circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end
power circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end
power circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end
power circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end
power circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
Contact CompatibilityM2
Contactor Coil Voltage230 V AC standard
Control Circuit Voltage Limits0.3...0.6 Uc (-40-70 °C):drop-out AC 50/60 Hz
0.8...1.1 Uc (-40-60 °C):operational AC 50 Hz
0.85...1.1 Uc (-40-60 °C):operational AC 60 Hz
1...1.1 Uc (60-70 °C):operational AC 50/60 Hz
Depth86 mm
Electrical Durability0.6 Mcycles 25 A AC-1 at Ue <= 440 V
2 Mcycles 9 A AC-3 at Ue <= 440 V
2 Mcycles 9 A AC-3e at Ue <= 440 V
Flame RetardanceV1 conforming to UL 94
Height77 mm
Hold-in Power Consumption In VA7.5-7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7-7 VA 50 Hz cos phi 0.3 (at 20 °C)
Inrush Power In VA70-70 VA 50 Hz cos phi 0.75 (at 20 °C)
70-70 VA 60 Hz cos phi 0.75 (at 20 °C)
Insulation Resistance> 10 MOhm for signalling circuit
Irms Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A at 440 V for power circuit conforming to IEC 60947
250 A DC for signalling circuit conforming to IEC 60947-5-1
Maximum Operating Rate3600 cyc/h 60 °C
Mechanical Durability15 Mcycles
Mechanical Robustnessshocks contactor closed: 15 Gn for 11 ms
shocks contactor open: 10 Gn for 11 ms
vibrations contactor closed: 4 Gn, 5...300 Hz
vibrations contactor open: 2 Gn, 5...300 Hz
Minimum Switching Current5 mA for signalling circuit
Minimum Switching Voltage17 V for signalling circuit
Motor Power KW2.2 kW at 220...230 V AC 50/60 Hz (AC-3)
2.2 kW at 220...230 V AC 50/60 Hz (AC-3e)
2.2 kW at 400 V AC 50/60 Hz (AC-4)
4 kW at 380...400 V AC 50/60 Hz (AC-3)
4 kW at 380...400 V AC 50/60 Hz (AC-3e)
4 kW at 415...440 V AC 50/60 Hz (AC-3)
4 kW at 415...440 V AC 50/60 Hz (AC-3e)
5.5 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
Motor Starter Typedirect on-line contactor
Net Weight0.32 kg
Non-overlap Time1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Operating Time12...22 ms closing
4...19 ms opening
Power Range1.1-2 kW at 200-240 V 3 phases
2.2-3 kW at 380-440 V 3 phases
4-6 kW at 380-440 V 3 phases
4-6 kW at 480-500 V 3 phases
Rated Breaking Capacity250 A at 440 V for power circuit conforming to IEC 60947
Signalling Circuit Frequency25...400 Hz
Tightening Torquecontrol circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Width45 mm
[Icw] Rated Short-time Withstand Current100 A - 1 s for signalling circuit
105 A 40 °C - 10 s for power circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
210 A 40 °C - 1 s for power circuit
30 A 40 °C - 10 min for power circuit
61 A 40 °C - 1 min for power circuit
[Ith] Conventional Free Air Thermal Current10 A (at 60 °C) for signalling circuit
25 A (at 60 °C) for power circuit
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to IEC 60947
[Ui] Rated Insulation Voltagepower circuit: 600 V CSA certified
power circuit: 600 V UL certified
power circuit: 690 V conforming to IEC 60947-4-1
signalling circuit: 600 V CSA certified
signalling circuit: 600 V UL certified
signalling circuit: 690 V conforming to IEC 60947-1
ENVIRONMENT
Ambient Air Temperature For Operation-40-60 °C
60-70 °C with derating
Ambient Air Temperature For Storage-60-80 °C
Fire Resistance850 °C conforming to IEC 60695-2-1
Heat Dissipation2-3 W at 50/60 Hz
IP Degree Of ProtectionIP20 front face conforming to IEC 60529
Operating Altitude0...3000 m
Overvoltage CategoryIII
Pollution Degree3
Product CertificationsBV
CCC
CSA
DNV
GL
GOST
LROS (Lloyds register of shipping)
RINA
UKCA
UL
Protective TreatmentTH conforming to IEC 60068-2-30
StandardsCSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60335-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
OTHER
Poles Description3P
[Us] Rated Supply VoltageTeSys D
TeSys Deca
Write Your Own Review
You're reviewing:TeSys D Contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 230 V AC Coil.
Your Rating