VIGILOHM INSULATION MONITOR IM400
This device belongs to the Vigilohm range designed to monitor ungrounded/IT electrical networks, in accordance to installation and products standards. According to standards, it is recommanded to equip your systems with Insulation Monitoring Devices (IMD). This device is dedicated to monitoring large and disturbed AC, DC and ACDC systems. It mesures the system insulation resistance by injecting a low frequency AC current between the network and ground. Configuration will be set depending on the installation. Settings are available on the front of the device, through the HMI screen, or from the communication port. Settings are related to network type, alarm and pre-alarm thresholds, alarm delay from 0 to 7200 secondes, and others are available. It monitors networks up to 830VAC when connected to neutral, 480V when connected to line, and 480VDC, with up to 500microfarad. The black and white screen can displays insulation resistance from 10 ohms to 10 megohms, capacitance and temporary faults. Auto-test starts automatically every 5 hours, and on demand. In case the system insulation resistance drops below the set threshold, meaning a ground fault occurred, an alarm is triggered thru the IMD output relay. Once no fault is monitored, the alarm is cleared, the alarm relay is back to normal. The device can be supplied by a 110VAC to 440VAC source or a 110VDC to 440VDC, all with a tolérence of plus or minus 15%. This product is installed flush mounted, an enclosure door for example. Front face ingress protection is IP5, rear IP20 and overvolage 300V category III. The monitoring device is equipped with a RS485 communication port, Modbus protocol.
-  440 VCA.
Label :  Vigilohm
-  range :  Vigilohm
-  range of product :  Vigilohm
-  product name :  Vigilohm IM
-  language :  Italian,French,German,Chinese,Portuguese,Russian,Spanish,English
-  device short name :  IM400
-  product or component type :  insulation monitoring device
-  device application :  marine application,standard environment application
-  application :  large or highly disturbed network
-  earthing system :  IT
-  Range Presentation :  The Vigilohm range of insulation monitoring devices (IMDs) provides you with a simple, reliable insulation monitoring, communication and fault location solution for your IT (ungrounded) networks.
This renewed and simplified offer helps increase personnel and equipment safety and process availability.
-  Range Benefits :  In low voltage electrical distributions, the combined use of an IT network arrangement and Insulation Monitoring Devices : 
-  Increases personnel safety
-  Reduces risk of fire or explosion
-  Increases process uptime
-  Ease maintenance and reduce OPEX
-  Range Application Presentation :  Your solution to make the best of your IT electrical network
-  Industry, including chemical, refinery, and transformation processes, where continuous process is critical
-  Infrastructure like airports, harbors, tunnels, and railways where safety is at stake
-  Healthcare areas like operation theaters and intensive care unit for security of patient and medical staff
-  Marine for safety reasons
-  Power Generation like photovoltaic, wind, hydro and nuclear, to prevent fire
-  Extraction, such as oil &gas and mining, to prevent fire and/or explosion
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 100...440 V AC 400 Hz +/- 15 % 100...440 V AC 50/60 Hz +/- 15 % 100...440 V DC +/- 15 % |
Display Type | digital display |
Product Or Component Type | insulation monitoring device |
Range Of Product | Vigilohm |
Thread Type | 0...120 min for signalling circuit |
Application | large or highly disturbed network |
Communication Port Protocol | Modbus |
Device Short Name | IM400 |
EAN13 | 3606480573347 |
Mounting Support | panel |
Range | Vigilohm |
Range Name | Vigilohm |
Signal Contacts Composition | 2 C/O standard or fail-safe |
Signalling Circuit Voltage | 250 V - AC at 6 A 48 V - DC at 1 A |
Type Of Measurement | earth leakage capacitance - measurement range: 0.1...500 µF network insulation resistance - measurement range: 10 Ohm...10 MOhm |
User Language | Chinese English French German Italian Portuguese Russian Spanish |
COMPLEMENTARY | |
Analogue Output Number | digital display |
Product Name | Vigilohm IM |
Time Delay Range | 0...120 min for signalling circuit |
Communication Port Support | RS485 |
Compatibility Code | IM400 |
Connections - Terminals | removable screw terminal block0.2-2.5 mm² |
Cut-out Dimensions | 112 x 148 mm |
Depth | 90 mm |
Device Application | marine application standard environment application |
Earthing System | IT |
Height | 123 mm |
Input Function | injection inhibition: 24 V AC 5 mA |
Insulation Shield | NO |
Local Signalling | green indicator light: satisfactory insulation resistance red indicator light: wiring or internal fault white indicator light: below prevention threshold yellow flashing indicator light: communication yellow indicator light: insulation fault |
Material | thermoplastic |
Measurement Current | 0-3 mA 0-375 µA 0-825 µA |
Measurement Voltage | 120-120 V 15-15 V 33-33 V |
Mounting Mode | flush-mounted |
Mounting Position | horizontal |
Net Weight | 0.75 kg |
Network Rated Voltage | 0-480 V - AC at 45...440 Hz (device connected to phase) 0-480 V - DC 0-830 V - AC at 45...440 Hz (device connected to neutral) |
Power Consumption In VA | 25 VA |
Relative Impedance | 40 kOhm - AC at 0.1...440 Hz 40 kOhm - DC |
Response Time | <= 4 s |
Test Function | manual self test |
Threshold Setting | alarm: 40 Ohm...500 kOhm pre-alarm: 1 kOhm...1 MOhm |
Type Of Installation | indoor |
Width | 159 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-55 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Dielectric Strength | 4000 V - AC 5500 V - DC |
Environmental Characteristic | exposure to damp heat in service conforming to IEC 60068-2-56 exposure to damp heat not in service conforming to IEC 60068-2-30 salt mist conforming to IEC 60068-2-52 |
IP Degree Of Protection | case: IP20 front face: IP54 |
Operating Altitude | <= 3000 m |
Overvoltage Category | III |
Pollution Degree | 2 |
Product Certifications | ABS CE CSA cULus DNV EAC RMRS UL |
Relative Humidity | 0-90 % |
Standards | CSA C22.2 No 14-05 IEC 60364-4-41 IEC 60364-5-51 IEC 61010-1 IEC 61557-8 UL 508 |
OTHER | |
Poles Description | insulation monitoring device |
[Us] Rated Supply Voltage | 100...440 V AC 400 Hz +/- 15 % 100...440 V AC 50/60 Hz +/- 15 % 100...440 V DC +/- 15 % |