VIGILOHM IM20 110-415VCA

Schneider
SKU
SE_IMD-IM20
Model
IMD-IM20
SGD $6,710.54

Short description of IMD IM20

VIGILOHM INSULATION MONITOR IM20
Country of Origin
India
-
+

UOM: Piece

In stock
In Stock 0

Minimum Order Quantity: 32

Backorder Leadtime: 5 To 7 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
VIGILOHM IM20 110-415VCA.
Label :  Vigilohm
-  range :  Vigilohm
-  range of product :  Vigilohm
-  product name :  Vigilohm IM
-  language :  Spanish,English,French,German,Russian,Chinese,Portuguese,Italian
-  device short name :  IM20
-  product or component type :  insulation monitoring device
-  device application :  marine application,standard environment application
-  application :  medium or low disturbed network
-  earthing system :  IT
-  Range Presentation :  The Vigilohm range of insulation monitoring devices (IMDs) provides you with a simple, reliable insulation monitoring, communication and fault location solution for your IT (ungrounded) networks.
This renewed and simplified offer helps increase personnel and equipment safety and process availability.
-  Range Benefits :  In low voltage electrical distributions, the combined use of an IT network arrangement and Insulation Monitoring Devices : 
-  Increases personnel safety
-  Reduces risk of fire or explosion
-  Increases process uptime
-  Ease maintenance and reduce OPEX
-  Range Application Presentation :  Your solution to make the best of your IT electrical network
-  Industry, including chemical, refinery, and transformation processes, where continuous process is critical
-  Infrastructure like airports, harbors, tunnels, and railways where safety is at stake
-  Healthcare areas like operation theaters and intensive care unit for security of patient and medical staff
-  Marine for safety reasons
-  Power Generation like photovoltaic, wind, hydro and nuclear, to prevent fire
-  Extraction, such as oil &gas and mining, to prevent fire and/or explosion
MAIN SPECIFICATIONS
Analogue Input Number110...415 V AC 45...440 Hz +/- 15 %
125...250 V DC +/- 15 %
Display Typedigital display
Product Or Component Typeinsulation monitoring device
Range Of ProductVigilohm
Thread Type0...5 min for signalling circuit
Applicationmedium or low disturbed network
Communication Port ProtocolModbus
Device Short NameIM20
EAN133606480321689
Mounting SupportDIN rail
panel
RangeVigilohm
Range NameVigilohm
Signal Contacts Composition1 C/O standard or fail-safe
Signalling Circuit Voltage12...24 V - DC at 6 A
250 V - AC at 6 A
Type Of Measurementearth leakage capacitance - measurement range: 0.1...40 µF
history of alarms
network insulation resistance - measurement range: 0.1 kOhm...10 MOhm
User LanguageChinese
English
French
German
Italian
Portuguese
Russian
Spanish
COMPLEMENTARY
Analogue Output Numberdigital display
Product NameVigilohm IM
Time Delay Range0...5 min for signalling circuit
Communication Port SupportRS485
Compatibility CodeIM20
Connections - Terminalsremovable screw terminal block0.2-2.5 mm²
Data Recordingalarm logs
Depth59 mm
Device Applicationmarine application
standard environment application
Earthing SystemIT
Height110 mm
Input Functioninjection inhibition: 24 V DC 5 mA
Insulation ShieldNO
Local Signallinggreen indicator light: satisfactory insulation resistance
orange flashing indicator light: transient fault
orange indicator light: below fault threshold
white indicator light: below prevention threshold
Materialthermoplastic
Measurement Current0-0.4 mA
Measurement Voltage75-75 V
Mounting Modeclip-on
flush-mounted
Net Weight0.25 kg
Network Rated Voltage0-345 V - DC
0-480 V - AC at 45...440 Hz (device connected to phase)
0-600 V - AC at 45...440 Hz (device connected to neutral)
Power Consumption In VA12 VA
Relative Impedance110 kOhm - AC at 0.1...440 Hz
Response Time<= 5 s
Test Functionmanual
self test
Threshold Settingfault: 0.5...500 kOhm
prevent: 1 kOhm...1 MOhm
Type Of Installationindoor
Width96 mm
ENVIRONMENT
Ambient Air Temperature For Operation-25-55 °C
Ambient Air Temperature For Storage-40-70 °C
Dielectric Strength4000 V - AC
5500 V - DC
Environmental Characteristicexposure to damp heat in service conforming to IEC 60068-2-56
exposure to damp heat not in service conforming to IEC 60068-2-30
salt mist conforming to IEC 60068-2-52
IP Degree Of Protectionfront face: IP52
Operating Altitude<= 3000 m
Overvoltage CategoryIII
Pollution Degree2
Product CertificationsBV
CE
DNV
EAC
RMRS
StandardsIEC 60364-4-41
IEC 61010-1
IEC 61326-2-4
IEC 61557-8
OTHER
Poles Descriptioninsulation monitoring device
[Us] Rated Supply Voltage110...415 V AC 45...440 Hz +/- 15 %
125...250 V DC +/- 15 %