GVAN20 - TeSys GV2 & GV3 - Auxiliary Contact Block - 2 NO
Schneider
SKU
SE_GVAN20
Model
GVAN20
SGD $13.25 All prices inclusive of GST
Short description of GVAN20
GVAN20. SIDE MOUNT AUX 2NO
Country of Origin
Czechia
TeSys GV2 & GV3
-  auxiliary contact block
-  2 NO.
Label :  TeSys GV2
-  range of product :  TeSys GV3,TeSys GV2
-  pole contact composition :  2 NO
-  range :  TeSys
-  device short name :  GVAN
-  product or component type :  auxiliary contact block
-  connections
-  terminals :  , , , , ,
-  product compatibility :  GV2ME,GV3P,GV2RT,GV2LE,GV2L,GV3L,GV2P
-  mounting location :  left side
-  Range Presentation : 
-  Manual and local control, when the motor circuit-breaker is used on its own, and automatic and remote control when combined with a contactor
-  Motor protection provided by thermal
- magnetic devices built into the circuit-breaker
-  No live parts are accessible to direct finger contact
-  The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
-  The addition of a shunt trip enables remote control of tripping
-  The control for the open or enclosed motor circuit-breaker can be locked in the “N/C" position using 3 padlocks
-  Connectors :  spring terminal, screw clamp
-  Range Benefits :  Complete protection concentrated in a single productCompact and simple to select, TeSys GV2 motor circuit-breakers are only 45 mm wide and are categorised
according to their level of performance and functions :  type of control, breaking capacity, motor protection and accessories.
-  Range Application Presentation : 
-  Industry, infrastructure, building, etc : 
-  Motor control and protection, in accordance with standards IEC 947-2 and IEC 947-4-1
-  Easily inserted in any configuration by screw or clip-fixing onto mounting rails
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  auxiliary contact block
-  2 NO.
Label :  TeSys GV2
-  range of product :  TeSys GV3,TeSys GV2
-  pole contact composition :  2 NO
-  range :  TeSys
-  device short name :  GVAN
-  product or component type :  auxiliary contact block
-  connections
-  terminals :  , , , , ,
-  product compatibility :  GV2ME,GV3P,GV2RT,GV2LE,GV2L,GV3L,GV2P
-  mounting location :  left side
-  Range Presentation : 
-  Manual and local control, when the motor circuit-breaker is used on its own, and automatic and remote control when combined with a contactor
-  Motor protection provided by thermal
- magnetic devices built into the circuit-breaker
-  No live parts are accessible to direct finger contact
-  The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
-  The addition of a shunt trip enables remote control of tripping
-  The control for the open or enclosed motor circuit-breaker can be locked in the “N/C" position using 3 padlocks
-  Connectors :  spring terminal, screw clamp
-  Range Benefits :  Complete protection concentrated in a single productCompact and simple to select, TeSys GV2 motor circuit-breakers are only 45 mm wide and are categorised
according to their level of performance and functions :  type of control, breaking capacity, motor protection and accessories.
-  Range Application Presentation : 
-  Industry, infrastructure, building, etc : 
-  Motor control and protection, in accordance with standards IEC 947-2 and IEC 947-4-1
-  Easily inserted in any configuration by screw or clip-fixing onto mounting rails
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Product Or Component Type | auxiliary contact block |
Range Of Product | TeSys Deca TeSys GV2 TeSys GV3 |
[Ue] Rated Operational Voltage | 24...240 V DC 48...690 V AC |
Device Short Name | GVAN |
EAN13 | 3389110343502 |
Pole Contact Composition | 2 NO |
Range | TeSys TeSys Deca |
Range Name | TeSys GV2 |
Rated Operational Power In W | 120 W at 240 V DC-13 - electrical durability: 100000 cycles 140 W at 110 V DC-13 - electrical durability: 100000 cycles 140 W at 24 V DC-13 - electrical durability: 100000 cycles 180 W at 60 V DC-13 - electrical durability: 100000 cycles 240 W at 48 V DC-13 - electrical durability: 100000 cycles |
COMPLEMENTARY | |
Communication Network Type | 24...240 V DC 48...690 V AC |
Colour | dark grey |
Compatibility Code | GVAN |
Depth | 66 mm |
Height | 89 mm |
Mechanical Durability | 100000 cycles |
Minimum Switching Current | 5 mA |
Minimum Switching Voltage | 17 V |
Mounting Location | left side |
Net Weight | 0.05 kg |
Product Compatibility | GV2L GV2LE GV2ME GV2P GV2RT GV3L GV3P |
Protection Type | GB2CB... circuit breaker gG fuse 10 A |
Rated Operational Power In VA | 300 VA at 48-48 V AC-15 - electrical durability: 100000 cycles 414 VA at 690-690 V AC-15 - electrical durability: 100000 cycles 500 VA at 110-127 V AC-15 - electrical durability: 100000 cycles 500 VA at 500-500 V AC-15 - electrical durability: 100000 cycles 650 VA at 440-440 V AC-15 - electrical durability: 100000 cycles 720 VA at 230-240 V AC-15 - electrical durability: 100000 cycles 850 VA at 380-415 V AC-15 - electrical durability: 100000 cycles |
Tightening Torque | 1.4 N.m - on screw clamp terminals |
Width | 9.3 mm |
[Ith] Conventional Free Air Thermal Current | 6 A |
[Ui] Rated Insulation Voltage | 600 V conforming to CSA C22.2 No 14 600 V conforming to UL 508 690 V conforming to IEC 60947-1 |
ENVIRONMENT | |
Environmental Characteristic | normal environment |
Product Certifications | UKCA |
OTHER | |
Poles Description | auxiliary contact block |
[Us] Rated Supply Voltage | TeSys Deca TeSys GV2 TeSys GV3 |
Write Your Own Review