EZC250H3200. MG EZC250 36KA 415V 3P 200A
Country of Origin
China
circuit breaker Easypact EZC250H
-  TMD
-  200 A
-  3 poles 3d.
Label :  EasyPact
-  range :  EasyPact
-  network type :  AC,DC
-  network frequency :  50/60 Hz
-  [In] rated current :  250 A at 40 °C
-  [Ui] rated insulation voltage :  N/A
-  range of product :  EasyPact
-  [Uimp] rated impulse withstand voltage :  N/A
-  [Ue] rated operational voltage :  N/A, N/A
-  breaking capacity code :  H
-  breaking capacity :  N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A
-  [Ics] rated service breaking capacity :  5 kA conforming to IEC 60947-2 550 V AC 50/60 Hz, 15 kA conforming to IEC 60947-2 125 V DC, 15 kA conforming to IEC 60947-2 250 V DC, 18 kA conforming to IEC 60947-2 380 V AC 50/60 Hz, 18 kA conforming to IEC 60947-2 400/415 V AC 50/60 Hz, 12.5 kA conforming to IEC 60947-2 440 V AC 50/60 Hz, 42.5 kA conforming to IEC 60947-2 110/130 V AC 50/60 Hz, 42.5 kA conforming to IEC 60947-2 220/230/240 V AC 50/60 Hz
-  suitability for isolation :  yes conforming to IEC 60947-2
-  utilisation category :  category A
-  product name :  EasyPact EZC
-  trip unit name :  TM
- D
-  product or component type :  circuit breaker
-  trip unit technology :  thermal
- magnetic
-  trip unit rating :  200-200 A at 50 °C
-  protection type :  overload protection,short-circuit protection
-  device short name :  Easypact EZC250H
-  circuit breaker name :  Easypact EZC250H
-  device application :  distribution
-  poles description :  3P
-  pollution degree :  3 conforming to IEC 60664-1, 3 conforming to IEC 947-1
-  protected poles description :  3t
-  Range Presentation :  The EasyPact EZC system is the simple and universal solution to satisfy all low voltage protection needs.
-  Easy to choose
-  Easy to install
-  Easy to use
-  Range Benefits :  It's so Easy and simple
-  Safety and protection
-  Simplicity
-  Range Application Presentation :  Protection of any electrical installation not exceeding 50kA/415V breaking capacity in particular for residential, buildings and industries
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  TMD
-  200 A
-  3 poles 3d.
Label :  EasyPact
-  range :  EasyPact
-  network type :  AC,DC
-  network frequency :  50/60 Hz
-  [In] rated current :  250 A at 40 °C
-  [Ui] rated insulation voltage :  N/A
-  range of product :  EasyPact
-  [Uimp] rated impulse withstand voltage :  N/A
-  [Ue] rated operational voltage :  N/A, N/A
-  breaking capacity code :  H
-  breaking capacity :  N/A, N/A, N/A, N/A, N/A, N/A, N/A, N/A
-  [Ics] rated service breaking capacity :  5 kA conforming to IEC 60947-2 550 V AC 50/60 Hz, 15 kA conforming to IEC 60947-2 125 V DC, 15 kA conforming to IEC 60947-2 250 V DC, 18 kA conforming to IEC 60947-2 380 V AC 50/60 Hz, 18 kA conforming to IEC 60947-2 400/415 V AC 50/60 Hz, 12.5 kA conforming to IEC 60947-2 440 V AC 50/60 Hz, 42.5 kA conforming to IEC 60947-2 110/130 V AC 50/60 Hz, 42.5 kA conforming to IEC 60947-2 220/230/240 V AC 50/60 Hz
-  suitability for isolation :  yes conforming to IEC 60947-2
-  utilisation category :  category A
-  product name :  EasyPact EZC
-  trip unit name :  TM
- D
-  product or component type :  circuit breaker
-  trip unit technology :  thermal
- magnetic
-  trip unit rating :  200-200 A at 50 °C
-  protection type :  overload protection,short-circuit protection
-  device short name :  Easypact EZC250H
-  circuit breaker name :  Easypact EZC250H
-  device application :  distribution
-  poles description :  3P
-  pollution degree :  3 conforming to IEC 60664-1, 3 conforming to IEC 947-1
-  protected poles description :  3t
-  Range Presentation :  The EasyPact EZC system is the simple and universal solution to satisfy all low voltage protection needs.
-  Easy to choose
-  Easy to install
-  Easy to use
-  Range Benefits :  It's so Easy and simple
-  Safety and protection
-  Simplicity
-  Range Application Presentation :  Protection of any electrical installation not exceeding 50kA/415V breaking capacity in particular for residential, buildings and industries
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity | 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 |
Breaking Capacity Code | H |
Contacts Type And Composition | 250 A at 40 °C |
Control Type | toggle |
Product Or Component Type | circuit breaker |
Range Of Product | EasyPact |
Trip Unit Name | TM-D |
[Ie] Rated Operational Current | toggle |
[Ue] Rated Operational Voltage | 250 V DC conforming to IEC 60947-2 550 V AC 50/60 Hz conforming to IEC 60947-2 |
Circuit Breaker Name | Easypact EZC250H |
Device Short Name | Easypact EZC250H |
EAN13 | 3303431999620 |
Mounting Support | backplate |
Network Type | AC DC |
Protected Poles Description | 3t |
Range | EasyPact |
Range Name | EasyPact EZC |
Suitability For Isolation | yes conforming to IEC 60947-2 |
Trip Unit Technology | thermal-magnetic |
Utilisation Category | category A |
COMPLEMENTARY | |
Communication Network Type | 250 V DC conforming to IEC 60947-2 550 V AC 50/60 Hz conforming to IEC 60947-2 |
Current Transformer Type | H |
Interlocked Device | 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 |
Product Name | EasyPact EZC |
[Ics] Rated Service Breaking Capacity | 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 |
[In] Rated Current | 250 A at 40 °C |
Compatibility Code | EZC250 |
Connection Pitch | 35 mm |
Depth | 60 mm |
Device Application | distribution |
Downside Connection | front |
Earth-leakage Protection | without |
Electrical Durability | category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 |
Height | 165 mm |
Local Signalling | positive contact indication |
Market Segment | small commercial |
Mechanical Durability | 10000 cycles |
Mounting Mode | fixed |
Network Frequency | 50/60 Hz |
Neutral Protection Setting | without protection |
Protection Type | overload protection short-circuit protection |
Trip Unit Rating | 200-200 A at 50 °C |
Upside Connection | front |
Width | 105 mm |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947-2 |
[Ui] Rated Insulation Voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -35-85 °C |
IK Degree Of Protection | IK07 conforming to IEC 62262 |
IP Degree Of Protection | IP20 conforming to IEC 60529 |
Pollution Degree | 3 conforming to IEC 60664-1 3 conforming to IEC 947-1 |
Standards | EN/IEC 60947-1 EN/IEC 60947-2 GB/T 14048.2 |
OTHER | |
Earth Leakage Current | TM-D |
Poles Description | 3P |
[Us] Rated Supply Voltage | EasyPact |