EZC100H3063 - Circuit Breaker Easypact EZC100H - TMD - 63 A - 3 Poles 3d.
Schneider
SKU
SE_EZC100H3063
Model
EZC100H3063
SGD $75.05 All prices inclusive of GST
Short description of EZC100H3063
EZC100H3063. Molded-case circuit breakers from 15 to 630 A, with fixed settings
Country of Origin
Thailand
range of product : EasyPact
-  product or component type : Circuit breaker
-  device short name : Easypact EZC100H
-  circuit breaker name : Easypact EZC100H
-  device application : Distribution
-  poles description : 3P
-  protected poles description : 3t
-  network type : ACDC
-  network frequency : 50/60 Hz
-  [In] rated current : 100 A at 40 °C
-  [Ui] rated insulation voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2
-  [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947-2
-  [Ue] rated operational voltage : 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2
-  breaking capacity code : H
-  breaking capacity : 10 kA Icu at 125 V DC 1P conforming to IEC 60947-210 kA Icu at 250 V DC 2P conforming to IEC 60947-210 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
-  [Ics] rated service breaking capacity : 5 kA at 125 V DC conforming to IEC 60947-25 kA at 250 V DC conforming to IEC 60947-25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-215 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-225 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-250 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-27.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
-  suitability for isolation : Yes conforming to IEC 60947-2
-  utilisation category : Category A
-  trip unit name : TM
- D
-  trip unit technology : Thermal
- magnetic
-  trip unit rating : 63 A at 50 °C
-  protection type : Short-circuit protectionOverload protection
-  pollution degree : 3 conforming to IEC 60947
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  product or component type : Circuit breaker
-  device short name : Easypact EZC100H
-  circuit breaker name : Easypact EZC100H
-  device application : Distribution
-  poles description : 3P
-  protected poles description : 3t
-  network type : ACDC
-  network frequency : 50/60 Hz
-  [In] rated current : 100 A at 40 °C
-  [Ui] rated insulation voltage : 690 V AC 50/60 Hz conforming to IEC 60947-2
-  [Uimp] rated impulse withstand voltage : 6 kV conforming to IEC 60947-2
-  [Ue] rated operational voltage : 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2
-  breaking capacity code : H
-  breaking capacity : 10 kA Icu at 125 V DC 1P conforming to IEC 60947-210 kA Icu at 250 V DC 2P conforming to IEC 60947-210 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2
-  [Ics] rated service breaking capacity : 5 kA at 125 V DC conforming to IEC 60947-25 kA at 250 V DC conforming to IEC 60947-25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-215 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-225 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-250 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-27.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2
-  suitability for isolation : Yes conforming to IEC 60947-2
-  utilisation category : Category A
-  trip unit name : TM
- D
-  trip unit technology : Thermal
- magnetic
-  trip unit rating : 63 A at 50 °C
-  protection type : Short-circuit protectionOverload protection
-  pollution degree : 3 conforming to IEC 60947
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity | 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 |
Breaking Capacity Code | H |
Contacts Type And Composition | 100 A at 40 °C |
Control Type | toggle |
Product Or Component Type | circuit breaker |
Range Of Product | EasyPact |
Trip Unit Name | TM-D |
[Ie] Rated Operational Current | toggle |
[Ue] Rated Operational Voltage | 250 V DC conforming to IEC 60947-2 550 V AC 50/60 Hz conforming to IEC 60947-2 |
Circuit Breaker Name | Easypact EZC100H |
Device Short Name | Easypact EZC100H |
Mounting Support | backplate |
Network Type | AC DC |
Protected Poles Description | 3t |
Range | EasyPact |
Range Name | EasyPact EZC |
Suitability For Isolation | yes conforming to IEC 60947-2 |
Trip Unit Technology | thermal-magnetic |
Utilisation Category | category A |
COMPLEMENTARY | |
Communication Network Type | 250 V DC conforming to IEC 60947-2 550 V AC 50/60 Hz conforming to IEC 60947-2 |
Current Transformer Type | H |
Interlocked Device | 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 |
Product Name | EasyPact EZC |
[Ics] Rated Service Breaking Capacity | 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 |
[In] Rated Current | 100 A at 40 °C |
Compatibility Code | EZC100 |
Connection Pitch | 25 mm |
Depth | 60 mm |
Device Application | distribution |
Downside Connection | front |
Earth-leakage Protection | without |
Electrical Durability | category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 |
Height | 130 mm |
Local Signalling | positive contact indication |
Market Segment | small commercial |
Mechanical Durability | 8500 cycles |
Mounting Mode | fixed |
Network Frequency | 50/60 Hz |
Neutral Protection Setting | without protection |
Protection Type | overload protection short-circuit protection |
Trip Unit Rating | 63-63 A at 50 °C |
Upside Connection | front |
Width | 75 mm |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947-2 |
[Ui] Rated Insulation Voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -35-85 °C |
IK Degree Of Protection | IK07 conforming to EN 50102 |
IP Degree Of Protection | IP20 conforming to IEC 60529 |
Pollution Degree | 3 conforming to IEC 60947 |
Standards | EN/IEC 60947-1 EN/IEC 60947-2 GB/T 14048.2 JIS C8201-2-2 |
OTHER | |
Earth Leakage Current | TM-D |
Poles Description | 3P |
[Us] Rated Supply Voltage | EasyPact |
Write Your Own Review