Circuit breaker, ComPacT NSX100M AC/DC, 25kA/415VAC, 2 poles, TMD trip unit 63A
Schneider
SKU
SE_C10M2TM063
Model
C10M2TM063
SGD $337.93
Schneider Electric green signature style for the entire ComPacT range
Estimated 40% reduction of wiring time for panel builders
Experience easier installation thanks to a new ergonomic front-plate design
Gain the confidence that all auxiliaries are on the right spot, and check that you have the right coil rating
Ergonomic new toggle for easier breaker manual operation
Environmental performance of the product
Estimated 40% reduction of wiring time for panel builders
Experience easier installation thanks to a new ergonomic front-plate design
Gain the confidence that all auxiliaries are on the right spot, and check that you have the right coil rating
Ergonomic new toggle for easier breaker manual operation
Environmental performance of the product
ComPacT NSX 100M is a complete 2 poles fixed circuit breaker designed to optimize space and breaking capacity. It is an optimal choice for all standard and specific applications. The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz. The operational voltage is 690VAC 50/60Hz. This product embeds a 63A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an fixed thermal overload protection and a fixed magnetic protection. The dimension is 161mm x 70mm x 86mm (H x W x D). It is compliant with international standards (EN/IEC 60947), CCC, EAC and marine specifications.
COMPLEMENTARY | |
---|---|
18 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 | 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
20000 cycles | Electrical durability |
20000 cycles at 277 V In/2 | 10000 cycles at 277 V In |
25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 | 25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
35 mm | Protection type |
36 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 | Mechanical durability |
85 kA at 250 V DC 50/60 Hz conforming to IEC 60947-2 | 85 kA at 500 V DC 50/60 Hz conforming to IEC 60947-2 |
Circuit breaker mounting mode | Fixed |
Depth (D) | 86 mm |
Earth-leakage protection | Without |
Flat on the back | upside connection |
Front | Downside connection |
Front | Connection pitch |
Height (H) | 161 mm |
Instantaneous protection pick-up adjustment type Ii | Fixed |
L : for overload protection (thermal) | I : for short-circuit protection (magnetic) |
Long-time pick-up adjustment type Ir (thermal protection) | Fixed |
Long-time protection delay adjustment type tr | Fixed |
Mounting position | Horizontal and vertical |
Mounting support | Backplate |
Power dissipation per pole | 8.61 W |
Trip unit rating | 63 A at 40 °C |
Width (W) | 70 mm |
[Ics] rated service short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
[Ii] instantaneous protection pick-up adjustment range | 500 A |
[Ir] long-time protection pick-up adjustment range | 1 x In |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 |
[Ui] rated insulation voltage | 750 V AC 50/60 Hz conforming to IEC 60947-2 |
ENVIRONMENT | |
Ambient air temperature for operation | -25…70 °C |
Ambient air temperature for storage | -50…85 °C |
EAC | Marine |
Electrical shock protection class | Class II |
IK degree of protection | IK07 conforming to IEC 62262 |
IP degree of protection | IP40 conforming to IEC 60529 |
Net weight | 1.2 kg |
Operating altitude | 0...2000 m without derating |
Overvoltage category | Class II |
Pollution degree | 3 conforming to IEC 60664-1 |
Product certifications | CCC |
Relative humidity | 0…95 % |
Standards | EN/IEC 60947 |
MAIN | |
18 kA Icu at 500/525 V AC 50/60 Hz 2P conforming to IEC 60947-2 | 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
25 kA Icu at 380/415 V AC 50/60 Hz 1P conforming to IEC 60947-2 | 25 kA Icu at 440 V AC 50/60 Hz 1P conforming to IEC 60947-2 |
500 V DC | Network type |
85 kA Icu at 250 V DC 50/60 Hz 1 pole conforming to IEC 60947-2 | 85 kA Icu at 500 V DC 50/60 Hz 2 poles in series conforming to IEC 60947-2 |
AC | DC |
Control type | Toggle |
Device application | Distribution |
Device short name | NSX100M |
Network frequency | 50/60 Hz |
Performance level | M 25 kA 415 V AC |
Poles description | 2P |
Product name | ComPacT NSX new generation |
Product or component type | Circuit breaker |
Protected poles description | 2D |
Range | ComPacT new generation |
Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
Trip unit name | TM-D |
Trip unit protection functions | LI |
Trip unit technology | Thermal-magnetic |
Utilisation category | Category A |
[Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 |
[In] rated current | 63 A at 40 °C |
[Ue] rated operational voltage | 690 V AC 50/60 Hz |
PACKING UNITS | |
1 | Package 1 Height |
1.254 kg | Unit Type of Package 2 |
12 | Package 2 Height |
13.0 cm | Package 1 Length |
17.5 cm | Package 1 Weight |
2000 m...5000 m with derating | Unit Type of Package 1 |
30.0 cm | Package 2 Width |
30.0 cm | Package 2 Length |
40.0 cm | Package 2 Weight |
8.0 cm | Package 1 Width |
PCE | Number of Units in Package 1 |
S03 | Number of Units in Package 2 |
Write Your Own Review