Your company account is blocked and you cannot place orders. If you have questions, please contact your company administrator.
Loading...
*All information are subjected to changes without prior notice.

BE700G-UK - APC Power-Saving Back-UPS 700VA, 230V, BS1363.

Schneider
SKU
SE_BE700G-UK
Model
BE700G-UK

Obsolete

All prices inclusive of GST

Short description of BE700G UK

BE700G-UK. Battery Backup & Surge Protector for Electronics and Computers
Obsolete
MAIN SPECIFICATIONS
Physical Interface230 V
Pressure Sensor Type405 W
Rated Power In W405 W
Cable Length6 ft
Range NameBack-UPS
GENERAL
Max Runtime7 min
Performance Multiplier1
Value Multiplier1
COMPLEMENTARY
Input Voltage230 V
Output Voltage230 V
Battery Life3-5 year(s)
Battery Typelead-acid battery
Colourblack
Data Line ProtectionRJ45 analog phone line for phone/fax/modem/DSL
RJ45 network line - 10/100 base-T Ethernet
Depth31.1 cm
Equipment Protection Policylifetime : 50000 GBP
Height8.9 cm
Input Voltage Limits180...266 V
Maximum Input Current10 A
Mounting Modenot rack-mountable
Net Weight6.93 kg
Network Frequency50/60 Hz +/- 5 Hz auto-sensing
Output Frequency47...63 Hz sync to mains
50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
Provided EquipmentCD with software
telephone cable
user manual
Rated Power In VA700 VA
Switching Current Capacity10 A
Transfer Time6 ms typical : 10 ms maximum
Width22.4 cm
COMMUNICATIONS & MANAGEMENT
Control PanelLED status display with on line : on battery : replace battery and overload indicators
PHYSICAL
Battery Charger Power5 W rated
Battery CurveC
Battery Recharge Time16 h
Curve Equationefficiency
Curve Load Maximum100 %
Curve X-axis Maximum100 %
Curve X-axis Minimum0 %
Curve X-axis Titleload
Curve X-axis Unitspercentage
Curve Y-axis Maximum100 %
Curve Y-axis Minimum50 %
Curve Y-axis Titleefficiency
Curve Y-axis Unitspercentage
Maximum Configurable Power In VA700 VA
Maximum Configurable Power In W405 W
Mounting Preferenceno preference
Nb Of Power Socket Outlets4 BS 1363
4 BS 1363 surge
Noise Suppressionfull time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449
Number Of Tare Power7 W
Redundantno
Show Note OP Temperatureno
Surge Energy Rate310 J
UPS Typestandby
USB Compatibleyes
OUTPUT
Curve Fixed Loss0.0107
Curve Load Minimum2 %
Curve Square Loss0.0017
Curve Test Cond IDCurve fit of data measured in accordance with the ENERGY STAR Test Method for Uninterruptible Power Supplies. All measurements taken in normal mode(s), at typical environmental conditions, with 230V/50Hz electrical input and balanced resistive load (PF =
Graph Display1
Output Voltage Tolerance+/- 5% static and 100% load step
Wave Typestepped approximation to a sinewave
BATTERIES & RUNTIME
Battery Capacity9 Ah
Battery Voltage12 V
ENVIRONMENT
Ambient Air Temperature For Operation0-40 °C
Ambient Air Temperature For Storage-15-40 °C
Operating Altitude0...30000 ft
Product CertificationsCE
Relative Humidity0-95 %
ENVIRONMENTAL
Acoustic Level40 dBA
Battery Power In VAh86 VAh runtime
Plug StandardBS1363A British
Storage Altitude0-30000 ft
Storage Relative Humidity0-95 %
UPS SizeWS