MAIN SPECIFICATIONS | |
---|---|
Physical Interface | 230 V |
Pressure Sensor Type | 405 W |
Rated Power In W | 405 W |
Cable Length | 6 ft |
Range Name | Back-UPS |
GENERAL | |
Max Runtime | 7 min |
Performance Multiplier | 1 |
Value Multiplier | 1 |
COMPLEMENTARY | |
Input Voltage | 230 V |
Output Voltage | 230 V |
Battery Life | 3-5 year(s) |
Battery Type | lead-acid battery |
Colour | black |
Data Line Protection | RJ45 analog phone line for phone/fax/modem/DSL RJ45 network line - 10/100 base-T Ethernet |
Depth | 31.1 cm |
Equipment Protection Policy | lifetime : 50000 GBP |
Height | 8.9 cm |
Input Voltage Limits | 180...266 V |
Maximum Input Current | 10 A |
Mounting Mode | not rack-mountable |
Net Weight | 6.93 kg |
Network Frequency | 50/60 Hz +/- 5 Hz auto-sensing |
Output Frequency | 47...63 Hz sync to mains 50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised |
Provided Equipment | CD with software telephone cable user manual |
Rated Power In VA | 700 VA |
Switching Current Capacity | 10 A |
Transfer Time | 6 ms typical : 10 ms maximum |
Width | 22.4 cm |
COMMUNICATIONS & MANAGEMENT | |
Control Panel | LED status display with on line : on battery : replace battery and overload indicators |
PHYSICAL | |
Battery Charger Power | 5 W rated |
Battery Curve | C |
Battery Recharge Time | 16 h |
Curve Equation | efficiency |
Curve Load Maximum | 100 % |
Curve X-axis Maximum | 100 % |
Curve X-axis Minimum | 0 % |
Curve X-axis Title | load |
Curve X-axis Units | percentage |
Curve Y-axis Maximum | 100 % |
Curve Y-axis Minimum | 50 % |
Curve Y-axis Title | efficiency |
Curve Y-axis Units | percentage |
Maximum Configurable Power In VA | 700 VA |
Maximum Configurable Power In W | 405 W |
Mounting Preference | no preference |
Nb Of Power Socket Outlets | 4 BS 1363 4 BS 1363 surge |
Noise Suppression | full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 |
Number Of Tare Power | 7 W |
Redundant | no |
Show Note OP Temperature | no |
Surge Energy Rate | 310 J |
UPS Type | standby |
USB Compatible | yes |
OUTPUT | |
Curve Fixed Loss | 0.0107 |
Curve Load Minimum | 2 % |
Curve Square Loss | 0.0017 |
Curve Test Cond ID | Curve fit of data measured in accordance with the ENERGY STAR Test Method for Uninterruptible Power Supplies. All measurements taken in normal mode(s), at typical environmental conditions, with 230V/50Hz electrical input and balanced resistive load (PF = |
Graph Display | 1 |
Output Voltage Tolerance | +/- 5% static and 100% load step |
Wave Type | stepped approximation to a sinewave |
BATTERIES & RUNTIME | |
Battery Capacity | 9 Ah |
Battery Voltage | 12 V |
ENVIRONMENT | |
Ambient Air Temperature For Operation | 0-40 °C |
Ambient Air Temperature For Storage | -15-40 °C |
Operating Altitude | 0...30000 ft |
Product Certifications | CE |
Relative Humidity | 0-95 % |
ENVIRONMENTAL | |
Acoustic Level | 40 dBA |
Battery Power In VAh | 86 VAh runtime |
Plug Standard | BS1363A British |
Storage Altitude | 0-30000 ft |
Storage Relative Humidity | 0-95 % |
UPS Size | WS |