2 Ethernet Ports Interface 10/100BASE-TX, ACE850TP for Sepam Series 40, 60, 80.

Schneider
SKU
SE_59658
Model
59658
SGD $1,846.37

Short description of 59658

Protection Relays for Complex Distribution Systems
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 4 To 6 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
range of product : Sepam series 40Sepam series 80 NPPSepam series 60Sepam series 80
-  device short name : ACE850TP
MAIN SPECIFICATIONS
Analogue Input Number110...240 V AC tolerance: - 20...10 %
24...250 V DC tolerance: - 20...10 %
Range Of ProductSepam series 40
Sepam series 60
Sepam series 80
Sepam series 80 NPP
Communication Port ProtocolARP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
FTP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
HTTP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
IEC 61850 network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
Modbus RTU network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
Modbus TCP/IP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
RSTP 801.1d 2004 network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
SNMP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
SNTP network: S-LAN and E-LAN interface: 2 Ethernet ports 10/100BASE-TX
Device Short NameACE850TP
Mounting Supportsymmetrical DIN rail
Range NameEasergy Sepam series 60
COMPLEMENTARY
Auxiliary Connection Terminalfunctional earth: ring lug 1 pin(s) 1 cable(s) tinned copper braid 4-4 mm²
protective earth: screw-type connector 1 pin(s) 1 cable(s) wire 2.5-2.5 mm² <3 m
supply: screw-type connector 3 pin(s) 1 cable(s) wire 0.5-2.5 mm²
supply: screw-type connector 3 pin(s) 1 cable(s) wire 1.5-1.5 mm²
supply: screw-type connector 3 pin(s) 1 cable(s) wire 2.5-2.5 mm²
supply: screw-type connector 3 pin(s) 2 cable(s) wire 0.5-1 mm²
supply: screw-type connector 3 pin(s) 2 cable(s) wire 1-1 mm²
supply: screw-type connector 4 pin(s) 1 cable(s) wire 0.5-2.5 mm²
supply: screw-type connector 4 pin(s) 1 cable(s) wire 1.5-1.5 mm²
supply: screw-type connector 4 pin(s) 1 cable(s) wire 2.5-2.5 mm²
supply: screw-type connector 4 pin(s) 2 cable(s) wire 0.5-1 mm²
supply: screw-type connector 4 pin(s) 2 cable(s) wire 1-1 mm²
Depth58 mm
Height127 mm
Local Signallinggreen LED1 for energized (front face)
green LED2 for communication status ok (front face)
green LED3 off for port 2 Ethernet 10 Mbit/s (front face)
green LED3 on for port 2 Ethernet 100 Mbit/s (front face)
green LED4 flashing for port 2 Ethernet sending data and receiving data (front face)
green LED5 off for port 1 Ethernet 10 Mbit/s (front face)
green LED5 on for port 1 Ethernet 100 Mbit/s (front face)
green LED6 flashing for port 1 Ethernet sending data and receiving data (front face)
red LED1 flashing for not set up or not base-unit connected (front face)
red LED1 off for de-energized (front face)
red LED1 remains ON for fault (front face)
Maximum Cable Distance Between Devices <100 m
Mechanical Robustnessearthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3
earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3
jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2
shocks de-energized (level: 2) : 30 Gn/11 ms conforming to IEC 60255-21-2
shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2
vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1
vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6
Mounting Modefixed
Net Weight0.4 kg
Width171 mm
Wire Stripping Lengthsupply: 8 mm
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Climatic Withstandcontinuous exposure to damp heat (in operation) : Ca: 10 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3
continuous exposure to damp heat (in storage) : Ca: 56 days, 93 % RH, 40 °C (104 °F) conforming to IEC 60068-2-3
exposure to cold (in operation) : Ab: - 25 °C (- 13 °F) conforming to IEC 60068-2-1
exposure to cold (in storage) : Ab: - 25 °C (- 13 °F) conforming to IEC 60068-2-1
exposure to dry heat (in operation) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2
exposure to dry heat (in storage) : Bb: 70 °C (158 °F) conforming to IEC 60068-2-2
influence of corrosion/gaz test 2 (in operation) : C: 21 days, 75 % RH, 25 °C (- 13 °F), 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60
influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.02 ppm NO2, 0.01 ppm Cl2 conforming to IEC 60068-2-60
salt mist (in operation) : Kb/2 conforming to IEC 60068-2-52
temperature variation with specified variation rate (in operation) : Nb: - 25 °C to 70 °C (- 13 °F to 158 °F) 5 °C/min (41 °F/min) conforming to IEC 60068-2-14
Electromagnetic Compatibility1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC and MD, conforming to ANSI C37.90.1
1 MHz damped oscillating wave: (immunity tests-conducted disturbances), III, 2.5 kV MC, 1 kV MD, conforming to IEC 60255-22-1
100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV MC, 1 kV MD, conforming to IEC 61000-4-12
conducted disturbance emission: (emission tests), B, conforming to EN 55022
conducted disturbance emission: (emission tests), conforming to IEC 60255-25
disturbing field emission: (emission tests), A, conforming to EN 55022
disturbing field emission: (emission tests), conforming to IEC 60255-25
electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3
electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2
fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1
fast transient bursts: (immunity tests-conducted disturbances), A or B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4
fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4
immunity to conducted RF disturbances: (immunity tests-conducted disturbances), 10 V, conforming to IEC 60255-22-6
immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (13 s), conforming to IEC 61000-4-8
immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3
immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2 (1995)
immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3
surges: (immunity tests-conducted disturbances), III, 2 kV MC, 1 kV MD, conforming to IEC 61000-4-5
voltage interruptions: (immunity tests-conducted disturbances), 100 %, 10 ms, conforming to IEC 60255-11
OTHER
[Us] Rated Supply Voltage110...240 V AC tolerance: - 20...10 %
24...250 V DC tolerance: - 20...10 %