Auxiliary Contact - 4 OC
Schneider
SKU
SE_48468
Model
48468
SGD $344.53 All prices inclusive of GST
Short description of 48468
BLOCK OF 4 OF CONTACTS FOR DRAWOUT BREAK
Country of Origin
France
auxiliary contact
-  4 OC.
Label : Masterpact NW
- range of product : Masterpact NW DC,Masterpact NW
- device short name : 4 OF
- product or component type : auxiliary contact
- Range Presentation : The worldwide benchmark for high current circuit breakersMasterpact NW circuit breakers are equipped with Micrologic control units that offer built-in power and energy metering in addition to basic or advanced protection functions. Two sizes are sufficient to cover applications from 800 to 6300 A, with breaking capacity from 42 to 150 kA. The range comes with a wide choice of standardized accessories. The universal design of the Masterpact circuit breaker line allows most accessories to be used across the entire line. It enables standardization of electrical switchboards by providing peace of mind in terms of choice, installation, and operation.
Specifications : 
-  Rated current :  800 to 6300 A
-  Breaking capacity :  42 to 150 kA at 220/415 V AC
-  Voltage rating :  up to 1150 V AC
-  2 physical sizes :  800 to 4000 A, and 4000 A to 6300 A
-  Draw out and fixed mount
-  3-pole and 4-pole construction
-  Electronic Micrologic control units, integrating current, voltage, power and energy metering enabling energy management, earth leakage protection, and other advanced protection or network analysis functions
-  Switch disconnectors version available
-  Optimized range of field
- installable auxiliaries and accessories
-  Different offers complying with different international standards :  IEC 60947, UL489, ANSI/UL1066
-  CCC, EAC and other local certifications
-  Compliance with specifications of marine classification companies :  Bureau Veritas, Lloyd's Register of Shipping, Det Norske Veritas, etc.
- Range Benefits : Masterpact NW circuit breakers contribute to reliability and continuity of service of your electrical installation thanks to : Optimized safety
Faultless protection Increased uptime with improved coordination with Micrologic electronic trip unit adjustability Complete selectivity and coordination High resistance to environmental stresses Integrated monitoring for energy efficiency
Improved uptime with complete monitoring solution in Smart Panels Seamless integration into power monitoring systems enabling to track energy consumption trends, anticipate potential damage and improve network reliability
Local and remote communication with trip cause (earth leakage, overload, short-circuit) and alarms (earth leakage, overload) allowing proactive operational and energy efficiency Advanced Micrologic control unit can assist in providing corrective, preventive and predictive maintenance, and energy management to identify potential savings :  energy consumption data, operation follow-up, network monitoring, preventative and predictive maintenance information, pre-alarm and alarm events
Seamless installation
Compactness Standardized range of auxiliaries and accessories Wide range of online and offline software tools that improve productivity at all stages of your project (Ecoreal, Ecodial, MyPact, Ecoreach) Masterpact NW is a part of EcoStruxure™ Power – Schneider Electric’s open, interoperable, IoT-enabled system architecture.
- Range Application Presentation : General applications in all types of low voltage electrical installationsSuitable in most applications for protection, measurement, monitoring and quality of energy, including generator protection and motor protection, in standard applications and specific applications demanding high performance, including : 
Industry :  mining operations, minerals, metals, and cement production, water & wastewater industry, automotive, food and beverage, etc. Oil & Gas extraction and processing, Chemicals industries Data centers infrastructure Healthcare infrastructure, hospitals Marine and offshore industry Infrastructures :  airports, railways, subways, tunnels, power plants, etc. Buildings :  commercial buildings, hotels, offices Wind turbines, solar, gensetsSpecial applications
Photovoltaic and DC networks (Masterpact NW DC & DC PV) Corrosive industrial environments (special versions) Mining industry (special 1000V versions) High short-circuit current limiting (ultra
- rapid Masterpact UR) Navy (Masterpact NT and NW Navy) UL 489 (Masterpact NT and NW UL 489 listed) Source-changeover systems (Transferpact) :  service sector (hospital operating rooms, computer rooms, etc.), industry (assembly lines, ship engine rooms, etc.), infrastructures (runway, railway, etc.)
-  4 OC.
Label : Masterpact NW
- range of product : Masterpact NW DC,Masterpact NW
- device short name : 4 OF
- product or component type : auxiliary contact
- Range Presentation : The worldwide benchmark for high current circuit breakersMasterpact NW circuit breakers are equipped with Micrologic control units that offer built-in power and energy metering in addition to basic or advanced protection functions. Two sizes are sufficient to cover applications from 800 to 6300 A, with breaking capacity from 42 to 150 kA. The range comes with a wide choice of standardized accessories. The universal design of the Masterpact circuit breaker line allows most accessories to be used across the entire line. It enables standardization of electrical switchboards by providing peace of mind in terms of choice, installation, and operation.
Specifications : 
-  Rated current :  800 to 6300 A
-  Breaking capacity :  42 to 150 kA at 220/415 V AC
-  Voltage rating :  up to 1150 V AC
-  2 physical sizes :  800 to 4000 A, and 4000 A to 6300 A
-  Draw out and fixed mount
-  3-pole and 4-pole construction
-  Electronic Micrologic control units, integrating current, voltage, power and energy metering enabling energy management, earth leakage protection, and other advanced protection or network analysis functions
-  Switch disconnectors version available
-  Optimized range of field
- installable auxiliaries and accessories
-  Different offers complying with different international standards :  IEC 60947, UL489, ANSI/UL1066
-  CCC, EAC and other local certifications
-  Compliance with specifications of marine classification companies :  Bureau Veritas, Lloyd's Register of Shipping, Det Norske Veritas, etc.
- Range Benefits : Masterpact NW circuit breakers contribute to reliability and continuity of service of your electrical installation thanks to : Optimized safety
Faultless protection Increased uptime with improved coordination with Micrologic electronic trip unit adjustability Complete selectivity and coordination High resistance to environmental stresses Integrated monitoring for energy efficiency
Improved uptime with complete monitoring solution in Smart Panels Seamless integration into power monitoring systems enabling to track energy consumption trends, anticipate potential damage and improve network reliability
Local and remote communication with trip cause (earth leakage, overload, short-circuit) and alarms (earth leakage, overload) allowing proactive operational and energy efficiency Advanced Micrologic control unit can assist in providing corrective, preventive and predictive maintenance, and energy management to identify potential savings :  energy consumption data, operation follow-up, network monitoring, preventative and predictive maintenance information, pre-alarm and alarm events
Seamless installation
Compactness Standardized range of auxiliaries and accessories Wide range of online and offline software tools that improve productivity at all stages of your project (Ecoreal, Ecodial, MyPact, Ecoreach) Masterpact NW is a part of EcoStruxure™ Power – Schneider Electric’s open, interoperable, IoT-enabled system architecture.
- Range Application Presentation : General applications in all types of low voltage electrical installationsSuitable in most applications for protection, measurement, monitoring and quality of energy, including generator protection and motor protection, in standard applications and specific applications demanding high performance, including : 
Industry :  mining operations, minerals, metals, and cement production, water & wastewater industry, automotive, food and beverage, etc. Oil & Gas extraction and processing, Chemicals industries Data centers infrastructure Healthcare infrastructure, hospitals Marine and offshore industry Infrastructures :  airports, railways, subways, tunnels, power plants, etc. Buildings :  commercial buildings, hotels, offices Wind turbines, solar, gensetsSpecial applications
Photovoltaic and DC networks (Masterpact NW DC & DC PV) Corrosive industrial environments (special versions) Mining industry (special 1000V versions) High short-circuit current limiting (ultra
- rapid Masterpact UR) Navy (Masterpact NT and NW Navy) UL 489 (Masterpact NT and NW UL 489 listed) Source-changeover systems (Transferpact) :  service sector (hospital operating rooms, computer rooms, etc.), industry (assembly lines, ship engine rooms, etc.), infrastructures (runway, railway, etc.)
MAIN SPECIFICATIONS | |
---|---|
Product Or Component Type | auxiliary contact |
Range Of Product | Masterpact NW Masterpact NW DC |
[Ie] Rated Operational Current | AC-12: 10 A at 240/380 V AC 50/60 Hz (standard) AC-12: 10 A at 480 V AC 50/60 Hz (standard) AC-12: 3 A at 380 V AC 50/60 Hz (low level) AC-12: 6 A at 24/48 V AC 50/60 Hz (low level) AC-12: 6 A at 240 V AC 50/60 Hz (low level) AC-12: 6 A at 690 V AC 50/60 Hz (standard) DC-12: 10 A at 125 V DC (standard) DC-12: 10 A at 24/48 V DC (standard) DC-12: 3 A at 250 V DC (low level) DC-12: 3 A at 250 V DC (standard) DC-12: 6 A at 125 V DC (low level) DC-12: 6 A at 24/48 V DC (low level) |
[Ue] Rated Operational Voltage | AC-12: 10 A at 240/380 V AC 50/60 Hz (standard) AC-12: 10 A at 480 V AC 50/60 Hz (standard) AC-12: 3 A at 380 V AC 50/60 Hz (low level) AC-12: 6 A at 24/48 V AC 50/60 Hz (low level) AC-12: 6 A at 240 V AC 50/60 Hz (low level) AC-12: 6 A at 690 V AC 50/60 Hz (standard) DC-12: 10 A at 125 V DC (standard) DC-12: 10 A at 24/48 V DC (standard) DC-12: 3 A at 250 V DC (low level) DC-12: 3 A at 250 V DC (standard) DC-12: 6 A at 125 V DC (low level) DC-12: 6 A at 24/48 V DC (low level) |
Device Short Name | 4 OF |
EAN13 | 3303430484684 |
Range Compatibility | Masterpact NW |
Range Name | Masterpact NW |
Signal Contacts Composition | 4 NO/NC |
COMPLEMENTARY | |
Auxiliary Contacts Type | low level standard |
Minimum Load | 100 mA at 24 V 2 mA at 15 V |
Mounting Mode | drawout |
OTHER | |
Poles Description | auxiliary contact |
[Us] Rated Supply Voltage | Masterpact NW Masterpact NW DC |
Write Your Own Review