Micrologic 6.0 A Trip Unit - LSIG - for NW 08..63 Drawout.

Schneider
SKU
SE_48361
Model
48361
SGD $2,539.86
Electronic control units for Masterpact NT/NW /UR and for Compact NS
Country of Origin
China
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 4 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
range : Masterpact
-  range of product : Masterpact NW
-  product or component type : Control unit
-  trip unit name : Micrologic 6.0 A
-  trip unit technology : Electronic
-  range compatibility : Masterpact NW08...40Masterpact NW40b...63Masterpact NW H10Masterpact NW H2 corrosion protection
-  device application : Distribution
-  Number of poles : 4P3P
-  protected poles description : 4t3t3t + N/2
-  trip unit protection functions : Selective + earth
- fault protection
-  protection type : for overload protection (long time) for short time short-circuit protection for instantaneous short-circuit protection for earth fault
-  Trip unit rating : 800 A at 50 °C1000 A at 50 °C1250 A at 50 °C1600 A at 50 °C2000 A at 50 °C2500 A at 50 °C3200 A at 50 °C4000 A at 50 °C5000 A at 50 °C6300 A at 50 °C
-  network type : AC
-  network frequency : 50/60 Hz
-  Circuit breaker mounting mode : Drawout
MAIN SPECIFICATIONS
Control Type3P
4P
Display Typedigital display
Product Or Component Typecontrol unit
Range Of ProductMasterpact NW
Trip Unit NameMicrologic 6.0 A
Network TypeAC
Protected Poles Description3t
3t + N/2
4t
RangeMasterpact
Range CompatibilityMasterpact NW H10
Masterpact NW H2 corrosion protection
Masterpact NW08...40
Masterpact NW40b...63
Range NameMicroLogic
Trip Unit Protection Functionsselective + earth-fault protection
Trip Unit Technologyelectronic
Type Of Measurementammeter
COMPLEMENTARY
Analogue Output Numberdigital display
Product NameMicrologic
Communication Of Datameasurement readout
protection and alarm settings
Device Applicationdistribution
Earth-leakage Protectionwithout
Ground-fault Pick-up Adjustment Typeadjustable 9 settings
Ground-fault Time Delay Adjustment Type -tgadjustable
Instantaneous Pick-up Adjustment Type Iiadjustable 9 settings
Long Time Delay Adjustment Typeadjustable 9 settings
Long Time Pick-up Adjustment Range0.4...1 x In
Long Time Pick-up Adjustment Type Iradjustable 9 settings
Mounting Modedrawout
Network Frequency50/60 Hz
Short-time Delay Adjustment Typeadjustable
Short-time Pick-up Adjustment Type Isdadjustable 9 settings
Thermal Memory20 mn
Zone Selective Interlocking ZSIwith
[Ig] Ground-fault Pick-up Adjustment Range0.2...1 x In for 400 A < In < 1250 A
0.3...1 x In for In <= 400 A
500...1200 A for In >= 1250 A
[Isd] Short-time Pick-up Adjustment Range1.5...10 x Ir
[tg] Ground-fault Time Delay Adjustment Range0.1-0.4 s I²t=on
0-0.4 s I²t=off
[tr] Long-time Delay Adjustment Range0.7-16.6 s at 7.2 x Ir
0.7-24 s at 6 x Ir
12.5-600 s at 1.5 x Ir
[tsd] Short-time Delay Adjustment Range0.1-0.4 s I²t=on
0-0.4 s I²t=off
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-85 °C
OTHER
Earth Leakage CurrentMicrologic 6.0 A
Poles Description3P
4P
[Us] Rated Supply VoltageMasterpact NW