Control Unit Micrologic 2.0 E, for Masterpact NT/NW, LI Protections.
Schneider
SKU
SE_47600
Model
47600
SGD $1,968.85 All prices inclusive of GST
Short description of 47600
Electronic control units for Masterpact NT/NW /UR and for Compact NS
Country of Origin
China
range : Masterpact
-  range of product : Masterpact NTMasterpact NW
-  product or component type : Control unit
-  trip unit name : Micrologic 2.0 E
-  trip unit technology : Electronic
-  range compatibility : Masterpact NT06...16Masterpact NW08...40Masterpact NW40b...63
-  device application : Distribution
-  Number of poles : 4P3P
-  protected poles description : 4t3t3t + N/2
-  trip unit protection functions : Basic protection
-  protection type : for overload protection (long time) for instantaneous short-circuit protection
-  Trip unit rating : 630 A at 50 °C800 A at 50 °C1000 A at 50 °C1250 A at 50 °C1600 A at 50 °C2000 A at 50 °C2500 A at 50 °C3200 A at 50 °C4000 A at 50 °C5000 A at 50 °C6300 A at 50 °C
-  network type : AC
-  network frequency : 50/60 Hz
-  Circuit breaker mounting mode : FixedDrawout
-  range of product : Masterpact NTMasterpact NW
-  product or component type : Control unit
-  trip unit name : Micrologic 2.0 E
-  trip unit technology : Electronic
-  range compatibility : Masterpact NT06...16Masterpact NW08...40Masterpact NW40b...63
-  device application : Distribution
-  Number of poles : 4P3P
-  protected poles description : 4t3t3t + N/2
-  trip unit protection functions : Basic protection
-  protection type : for overload protection (long time) for instantaneous short-circuit protection
-  Trip unit rating : 630 A at 50 °C800 A at 50 °C1000 A at 50 °C1250 A at 50 °C1600 A at 50 °C2000 A at 50 °C2500 A at 50 °C3200 A at 50 °C4000 A at 50 °C5000 A at 50 °C6300 A at 50 °C
-  network type : AC
-  network frequency : 50/60 Hz
-  Circuit breaker mounting mode : FixedDrawout
MAIN SPECIFICATIONS | |
---|---|
Control Type | 3P 4P |
Display Type | digital display |
Product Or Component Type | control unit |
Trip Unit Name | Micrologic 2.0 E |
Network Type | AC |
Protected Poles Description | 3t 3t + N/2 4t |
Range Compatibility | Compact NS Masterpact MT Masterpact NT Masterpact NW |
Range Name | MicroLogic |
Trip Unit Protection Functions | basic protection |
Trip Unit Technology | electronic |
Type Of Measurement | energy meter |
COMPLEMENTARY | |
Analogue Output Number | digital display |
Product Name | Micrologic |
Communication Of Data | measurement readout protection and alarm settings |
Device Application | distribution |
Earth-leakage Protection | without |
Instantaneous Pick-up Adjustment Type Ii | adjustable 9 settings |
Long Time Delay Adjustment Type | adjustable 9 settings |
Long Time Pick-up Adjustment Range | 0.4...1 x In |
Long Time Pick-up Adjustment Type Ir | adjustable 9 settings |
Mounting Mode | drawout fixed |
Network Frequency | 50/60 Hz |
Thermal Memory | 20 mn |
Zone Selective Interlocking ZSI | without |
[tr] Long-time Delay Adjustment Range | 0.7-16.6 s at 7.2 x Ir 0.7-24 s at 6 x Ir 12.5-600 s at 1.5 x Ir |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -40-85 °C |
OTHER | |
Earth Leakage Current | Micrologic 2.0 E |
Poles Description | 3P 4P |
Write Your Own Review