Schneider
SKU
SE_47483
Model
47483
SGD $258.05 All prices inclusive of GST

Short description of 47483

M2C PROGRAMMABLE CONTACTS FOR DRAWOUT BR
Country of Origin
France
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 4 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

*All information are subjected to changes without prior notice.
programmable contacts M2C
-  for drawout circuit breaker Masterpact NT.
Label : Micrologic
- range of product : Masterpact NT
- range : Masterpact
- product or component type : programmable contact
- device application : control
- Range Presentation : Offers all types of current protection and advanced protection, measurement and communication : 
-  4 levels of protection against overloads and short circuits for the protection levels :  2.0 (LI), 5.0(LSI), 6.0(LSIG), 7.0 (LSIV, built-in earth leakage protection)
-  4 types of measurement :  A (Ammeter), E (Energy), P (Power) and H (Harmonics)​
-  Energy reduction maintenance setting (ERMS) function available for arc flash protection​ for Micrologic P and Micrologic H
-  Measurement accuracy :  Class 0.5 for voltage, class 1.5 for current and class 2 for active power and energy ​
-  Reliability of protection function ensured due to the separation of protection (dedicated ASIC) and the function of measurement and communication ​
-  Compatible with both Ethernet and Modbus SL protocol​
-  Operating assistance to diagnose tripping cause and maintenance information
- Range Benefits : Enhanced protection ​
-  Optimize your selectivity and coordination capabilities with protection accuracy for a wide temperature range (-25 to 70 °C)​
-  Greater flexibility as the electronic trip unit allows for a large long time delay (0.4 to 1 x In)​
-  Possible added electrical fire protection with ground fault alarms or tripping protection functions that detect ground fault current that is above the overcurrent protection threshold Optimized energy management :  ​
-  Integration into a power monitoring system to track energy consumption trends, anticipate potential damage and improve network reliability. The micrologic trip unit provides : ​
-  Energy consumption data​
-  Operation follow-up​
-  Network monitoring​
-  Preventative and predictive maintenance information​
-  Pre-alarm and alarm events ​
-  Working with Enerlin’X IF communication interfaces, the Micrologic control unit inside our Smart Panels becomes a connected product within our EcoStruxure Power architecture
- Range Application Presentation : Suitable for protection, measurement, monitoring and quality of energy for most types of low voltage (LV) electrical network applications, including : ​
-  Buildings :  data centers, commercial buildings, hotels, hospitals, offices ​
-  Industry :  mining and minerals, automotive, food and beverage and chemical industry ​
-  Energy and infrastructures :  airports, oil and gas, water treatment and marine​
-  Special application :  wind turbines, solar, GenSets, motor protection ​
MAIN SPECIFICATIONS
Product Or Component Typeprogrammable contact
Range Of ProductMasterpact NT
[Ie] Rated Operational Current0.15 A at 250 V DC
0.4 A at 125 V DC
1.5 A at 48 V DC
1.8 A at 24 V DC
3 A at 380 V AC
5 A at 240 V AC
[Ue] Rated Operational Voltage0.15 A at 250 V DC
0.4 A at 125 V DC
1.5 A at 48 V DC
1.8 A at 24 V DC
3 A at 380 V AC
5 A at 240 V AC
EAN133303430474838
RangeMasterpact
Range Compatibility MasterPact NT circuit breaker
Range NameMicrologic
COMPLEMENTARY
Device Applicationcontrol
Minimum Load100 mA at 24 V
Mounting Modedrawout
OTHER
Poles Descriptionprogrammable contact
[Us] Rated Supply VoltageMasterpact NT