XPSDMB1132 - Module XPSDM - 2 Coded Magnetic Switch - 24 V DC.
Schneider
SKU
SE_XPSDMB1132
Model
XPSDMB1132
Obsolete
Short description of XPSDMB1132
XPSDMB1132. Safety Modules
Obsolete
range of product : Preventa Safety automation
-  product or component type : Preventa safety module
-  safety module name : XPSDMB
-  safety module application : Monitoring 2 coded magnetic switches
-  function of module : Coded magnetic switch monitoring
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
-  safety reliability data : MTTFd = 83.1 years conforming to EN/ISO 13849-1DC > 99 % conforming to EN/ISO 13849-1PFHd = 3.92E
- 9 1/h conforming to EN/IEC 62061
-  [Us] rated supply voltage : 24 V DC
-  20...20 %
-  output type : Relay, 2 NO circuit(s), volt
- free
-  number of additional circuits : 2 solid state outputs
-  product or component type : Preventa safety module
-  safety module name : XPSDMB
-  safety module application : Monitoring 2 coded magnetic switches
-  function of module : Coded magnetic switch monitoring
-  safety level : Can reach PL e/category 4 conforming to EN/ISO 13849-1Can reach SILCL 3 conforming to EN/IEC 62061
-  safety reliability data : MTTFd = 83.1 years conforming to EN/ISO 13849-1DC > 99 % conforming to EN/ISO 13849-1PFHd = 3.92E
- 9 1/h conforming to EN/IEC 62061
-  [Us] rated supply voltage : 24 V DC
-  20...20 %
-  output type : Relay, 2 NO circuit(s), volt
- free
-  number of additional circuits : 2 solid state outputs
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24 V DC - 20...20 % |
Breaking Capacity | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
Continuous Power | can reach PL e/category 4 conforming to EN/ISO 13849-1 can reach SILCL 3 conforming to EN/IEC 62061 |
Product Or Component Type | Preventa safety module |
Range Of Product | Preventa Safety automation |
[Uc] Control Circuit Voltage | 28 V DC |
Function Of Module | coded magnetic switch monitoring |
Mounting Support | 35 mm symmetrical DIN rail |
Number Of Additional Circuits | 2 solid state outputs |
Range Name | Preventa XPS |
Safety Module Application | monitoring 2 coded magnetic switches |
Safety Module Name | XPSDMB |
COMPLEMENTARY | |
Interlocked Device | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
Product Name | relay, 2 NO circuit(s), volt-free |
Associated Fuse Rating | 4 A gG for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
Connections - Terminals | captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
Current Consumption | 8 mA at 28 V DC on power supply |
Input Protection Type | internal, electronic |
Local Signalling | 3 LEDs |
Maximum Line Resistance | 100 Ohm |
Maximum Response Time On Input Open | 20 ms |
Minimum Output Current | 10 mA for relay output |
Minimum Output Voltage | 17 V for relay output |
Net Weight | 0.25 kg |
Output Thermal Current | 6 A per relay for relay output |
Output Type | relay, 2 NO circuit(s), volt-free |
Power Consumption In W | 2.5 W |
Safety Reliability Data | DC > 99 % conforming to EN/ISO 13849-1 MTTFd = 83.1 years conforming to EN/ISO 13849-1 PFHd = 3.92E-9 1/h conforming to EN/IEC 62061 |
Synchronisation Time Between Inputs | < 0.5 s |
[Ith] Conventional Free Air Thermal Current | 12 A |
[Uimp] Rated Impulse Withstand Voltage | 4 kV overvoltage category III conforming to DIN VDE 0110 part 1 4 kV overvoltage category III conforming to IEC 60947-5-1 |
[Ui] Rated Insulation Voltage | 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 300 V (pollution degree 2) conforming to IEC 60947-5-1 |
ENVIRONMENT | |
Safety Level | can reach PL e/category 4 conforming to EN/ISO 13849-1 can reach SILCL 3 conforming to EN/IEC 62061 |
Ambient Air Temperature For Operation | -10-55 °C |
Ambient Air Temperature For Storage | -25-85 °C |
IP Degree Of Protection | IP20 (terminals) conforming to EN/IEC 60529 IP40 (enclosure) conforming to EN/IEC 60529 |
Product Certifications | CSA TÜV UL |
Standards | EN 1088/ISO 14119 EN/IEC 60204-1 EN/IEC 60947-5-1 |
OTHER | |
Poles Description | Preventa safety module |
[Us] Rated Supply Voltage | 24 V DC - 20...20 % |