XCSM3910L1 - Safety Limit Switch, Telemecanique Safety Switches XCS, XCSM, Metal, Steel Plunger, 2 NC + 1 NO, Cable 1 M

Telemecanique
SKU
SE_XCSM3910L1
Model
XCSM3910L1
SGD $120.12 All prices inclusive of GST

Short description of XCSM3910L1

XCSM3910L1. LS 1NO2NC SA 1M CABLE METAL END PLUN
Country of Origin
Indonesia
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 3 To 5 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

safety limit switch XCSM
-  metal
-  steel plunger
-  2 NC + 1 NO
-  cable 1 m.
Label :  Preventa XCS
-  range of product :  Preventa Safety detection
-  contacts type and composition :  1 NC + 1 NC + 1 NO
-  contact operation :  snap action
-  product or component type :  safety limit switch
-  component name :  XCSM
-  design :  miniature
-  material :  metal
-  head type :  plunger head
-  protection technology :  plastic protective cover, secured by 5-lobe socket head safety screw
-  type of approach :  on end approach
-  type of operator :  metal end plunger
-  Range Presentation :  Protection of operators by stopping the machine when the actuator attached to the machine guard is withdrawn from the head of the switch.


-  For heavy duty industrial machines with quick rundown time :  Key operated switches XCSA, XCSB, XCSC slow rundown time :  Key operated switches with solenoid XCSLF, XCSE
-  For light industrial machines with quick rundown time :  Key operated switches XCSMP, XCSPA, XCSTA with slow rundown time :  Key operated switches with solenoid XCSLE, XCSTEProtection of operators by stopping the light industrial machine with quick rundown time when


-  the operating lever attached to the hinged machine guard is displaced by 5° :  safety switches XCSPL, XCSTL the guard hinge rotates through safety switches XCSPR, XCSTR
-  the gate with imprecise guidance and/or subject to frequent washing is opened Coded magnetic switches :  XCSDMC, XCSDMP, XCSDMR Coded magnetic system, complete device including both coded magnetic and safety module :  XCSDM3, XCSDM4Protection of operators by stopping heavy or light industrial machine with quick rundown time when the gate is opened :  Safety limit switches XCSM, XCSD, XCSP
-  Range Benefits :  One of the most comprehensive catalogues of industrial safety switches on the market.Save time in setting up, and place and in the cabinet with our innovative coded magnetic system.Increase productivity thanks to the third contact dedicated to diagnostics
-  Range Application Presentation :  As far as safety is concerned all dangerous machines in all sectors are involved. Such as packaging, handling, robotics, machine tools, presses, automotive sector.
MAIN SPECIFICATIONS
Contacts Type And Composition1 NC + 1 NC + 1 NO
Continuous Powercan reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Discrete Input Number1 NC + 1 NC + 1 NO
Product Or Component Typesafety limit switch
Range Of ProductTelemecanique Safety switches XCS
Body Materialzamak
Cable Length1 m
Component NameXCSM
Designminiature
EAN133389110243758
Head Typeplunger head
Number Of Poles3
Protection Technologyplastic protective cover, secured by 5-lobe socket head safety screw
Range NamePreventa XCS
Short-circuit Protection6 A cartridge fuse type gG (gl)
Type Of Approachon end approach
Type Of Operatormetal end plunger
COMPLEMENTARY
Cable Composition7 x 0.5 mm²
Contact Code DesignationB300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN 60947-5-1
B300, AC-15 (Ue = 240 V, Ie = 1.5 A) conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN 60947-5-1
R300, DC-13 (Ue = 250 V, Ie = 0.1 A) conforming to EN/IEC 60947-5-1 appendix A
Contact Operationsnap action
Depth16 mm
Electrical Connectionpre-cabled
Fixing Modeby the body
Head Materialzamak
Height60-60 mm
Materialmetal
Maximum Actuation Speed0.5 m/s
Maximum Resistance Across Terminals25 MOhm conforming to IEC 60255-7 category 3
Mechanical Durability10000000 cycles
Minimum Actuation Speed0.01 m/min
Minimum Force For Tripping8.5 N
Net Weight0.165 kg
Positive Openingwith NC contact
Positive Opening Minimum Force42.5 N
Repeat Accuracy0.05 mm on the tripping points
Safety Reliability DataB10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Width30 mm
[Uimp] Rated Impulse Withstand Voltage4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
[Ui] Rated Insulation Voltage300 V conforming to CSA C22.2 No 14
300 V conforming to UL 508
400 V (pollution degree 3) conforming to IEC 60947-5-1
ENVIRONMENT
Safety Levelcan reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-70 °C
Electrical Shock Protection Classclass I conforming to EN/IEC 61140
class I conforming to NF C 20-030
IK Degree Of ProtectionIK06 conforming to EN 50102
IP Degree Of ProtectionIP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP68 conforming to IEC 60529
Product CertificationsCSA
UL
Protective TreatmentTC
Shock Resistance25 gn for 18 ms conforming to IEC 60068-2-27
StandardsCSA C22.2 No 14
EN 1088
EN/IEC 60204-1
EN/IEC 60947-5-1
UL 508
Vibration Resistance5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
OTHER
Poles Descriptionsafety limit switch
[Us] Rated Supply VoltageTelemecanique Safety switches XCS