Short description of XCSE8312

XCSE8312. Safety switches
Country of Origin
Indonesia
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 3 To 5 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

range of product : Telemecanique Safety switches XCS
-  product or component type : Safety switch
-  component name : XCSE
-  design : Rectangular
-  material : Metal
-  head type : Key operated turret head
-  contacts type and composition : 3 NC
-  contact operation : Slow-break, simultaneous
-  solenoid contacts type and composition : 1 NC + 1 NO (slow-break, simultaneous)
-  cable entry : 2 entries tapped for M20 x 1.5
-  electromagnet interlocking : Locking on de
- energisation and unlocking on energisation of solenoid
-  [Us] solenoid rated supply voltage : 24 V
-  20...10 %
-  cable outer diameter : 7…13 mm
-  electrical connection : Terminal, clamping capacity :  1 x 0.5...2 x 1.5 mm² with or without cable end
-  number of poles : 3
-  locking options description : With interlocking, locking by solenoid
-  local signalling : 1 LED (green) for guard closed and locked
-  signalling circuit voltage : 24/48 V (voltage limits :  20...52 V)
MAIN SPECIFICATIONS
Analogue Input Number24 V - 20...10 %
Contacts Type And Composition3 NC
Continuous Powercan reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Discrete Input Number3 NC
Product Or Component Typesafety switch
Range Of ProductTelemecanique Safety switches XCS
[Ie] Rated Operational Current0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1
3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1
[Ue] Rated Operational Voltage0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1
3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1
Body Materialzamak
Component NameXCSE
Designrectangular
Electromagnet Interlockinglocking on de-energisation and unlocking on energisation of solenoid
Head Typekey operated turret head
Number Of Poles3
Range NamePreventa XCS
Short-circuit Protection10 A cartridge fuse type gG (gl)
Signalling Circuit Voltage24/48 V (voltage limits: 20...52 V)
Solenoid Contacts Type And Composition1 NC + 1 NO (slow-break, simultaneous)
[Ithe] Conventional Enclosed Thermal Current6 A
COMPLEMENTARY
Actuator Forcible Withdrawal Rtc2000 N
Cable Entry2 entries tapped for M20 x 1.5
Cable Outer Diameter7-13 mm
Contact Operationslow-break, simultaneous
Depth44 mm
Electrical Connectionterminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Head Materialzamak
Height146-146 mm
Load Factor1
Local Signalling1 LED (green) for guard closed and locked
Locking Options Descriptionwith interlocking, locking by solenoid
Materialmetal
Maximum Actuation Speed0.5 m/s
Maximum Operating Rate10 cyc/mn for maximum durability
Mechanical Durability1000000 cycles
Minimum Actuation Speed0.01 m/s
Minimum Actuator Force For Extraction20 N
Net Weight1.14 kg
Positive Openingwith NC contact
Power Consumption In VA10 VA inrush
10 VA sealed
Protection Typeovervoltage protection for signalling circuit
Safety Reliability DataB10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Signalling Circuit Consumption7 mA
Signalling Circuit TypeAC/DC
Supply Frequency50/60 Hz
Supply Voltage TypeAC/DC
Width98 mm
[Uimp] Rated Impulse Withstand Voltage6 kV conforming to EN/IEC 60947-5-1
[Ui] Rated Insulation Voltage50 V conforming to EN/IEC 60947-1 for signalling circuit
ENVIRONMENT
Safety Levelcan reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1
can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Ambient Air Temperature For Operation-25-40 °C
Ambient Air Temperature For Storage-40-70 °C
Electrical Shock Protection Classclass I conforming to EN/IEC 61140
IP Degree Of ProtectionIP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Product CertificationsCSA
UL
Protective TreatmentTC
Shock Resistance10 gn for 11 ms conforming to IEC 60068-2-27
StandardsCSA C22.2 No 14
EN 1088/ISO 14119
EN/IEC 60204-1
EN/IEC 60947-5-1
EN/ISO 12100
UL 508
Vibration Resistance5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
OTHER
Poles Descriptionsafety switch
[Us] Rated Supply Voltage24 V - 20...10 %