TM4PDPS1 - Module Network TM4 1 Profibus DP Slave.
Schneider
SKU
SE_TM4PDPS1
Model
TM4PDPS1
SGD $931.17 All prices inclusive of GST
Short description of TM4PDPS1
TM4PDPS1. For performance-demanding applications
Country of Origin
Indonesia
product or component type : Profibus DP communication module
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Product Or Component Type | Profibus DP communication module |
Communication Port Protocol | Profibus DP V0 Profibus DP V1 |
Mounting Support | plate or panel with fixing kit top hat type TH35-15 rail conforming to IEC 60715 top hat type TH35-7.5 rail conforming to IEC 60715 |
Range Compatibility | Modicon M241 Modicon M251 |
Range Name | Logic Controller - Modicon M241 |
COMPLEMENTARY | |
Current Consumption | 290 mA at 5 V DC for communication bus |
Depth | 90 mm |
Electrical Connection | screw connector terminal for connecting the functional ground SUB-D 9 1 female connector for connecting Profibus |
Height | 90 mm |
Insulation | between bus and internal logic at 1000 V DC |
Integrated Connection Type | Profibus DP: female SUB-D 9 connector |
Local Signalling | 1 LED (green/red) for communication 1 LED (green/yellow) for power supply |
Marking | CE |
Net Weight | 0.1 kg |
Power Dissipation In W | 1.5 W |
Product Compatibility | Modicon M241 logic controller Modicon M251 logic controller |
Surge Withstand | 0.5 kV I/O differential mode conforming to EN/IEC 61000-4-5 0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 1 kV I/O common mode conforming to EN/IEC 61000-4-5 1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5 1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 1 kV relay output differential mode conforming to EN/IEC 61000-4-5 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5 2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5 2 kV relay output common mode conforming to EN/IEC 61000-4-5 |
Transmission Rate | 1.5 Mbit/s for bus length of 200-200 m 187.5 kbit/s for bus length of 1000-1000 m 3...12 Mbit/s for bus length of 100-100 m 500 kbit/s for bus length of 400-400 m 9.6...93.75 kbit/s for bus length of 1200-1200 m |
Width | 25 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -10-50 °C vertical installation -10-55 °C horizontal installation |
Ambient Air Temperature For Storage | -25-70 °C |
Electromagnetic Emission | conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10-150 kHz conforming to EN/IEC 55011 conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5-30 MHz conforming to EN/IEC 55011 conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5-300 MHz conforming to EN/IEC 55011 conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15-0.5 MHz conforming to EN/IEC 55011 conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150-1500 kHz conforming to EN/IEC 55011 radiated emissions - test level: 24 dBμV/m QP at 156-165 MHz conforming to Marine specification (LR, ABS, DNV, GL) radiated emissions - test level: 40 dBμV/m QP class A at 30-230 MHz conforming to EN/IEC 55011 radiated emissions - test level: 47 dBμV/m QP class A at 230-1000 MHz conforming to EN/IEC 55011 radiated emissions - test level: 54 dBμV/m QP at 100-2000 MHz conforming to Marine specification (LR, ABS, DNV, GL) radiated emissions - test level: 60...54 dBμV/m QP at 30-100 MHz conforming to Marine specification (LR, ABS, DNV, GL) radiated emissions - test level: 80...50 dμV/m QP at 150-30000 kHz conforming to Marine specification (LR, ABS, DNV, GL) |
IP Degree Of Protection | IP20 with protective cover in place |
Operating Altitude | 0...2000 m |
Pollution Degree | 2 |
Product Certifications | C-Tick cULus |
Relative Humidity | 10-95 %, without condensation (in operation) 10-95 %, without condensation (in storage) |
Resistance To Conducted Disturbances | 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL) |
Resistance To Electromagnetic Fields | 1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 |
Resistance To Electrostatic Discharge | 4 kV on contact conforming to EN/IEC 61000-4-2 6 kV on contact conforming to Marine specification (LR, ABS, DNV, GL) 8 kV in air conforming to EN/IEC 61000-4-2 8 kV in air conforming to Marine specification (LR, ABS, DNV, GL) |
Resistance To Fast Transients | 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 1 kV (serial link) conforming to EN/IEC 61000-4-4 1.5 kV (I/O) conforming to EN/IEC 61000-4-4 2 kV (power lines) conforming to EN/IEC 61000-4-4 2 kV (relay output) conforming to EN/IEC 61000-4-4 |
Shock Resistance | 15 gn for 11 ms |
Standards | EIA-485 EN/IEC 61131-2 UL 508 |
Vibration Resistance | 0.7 gn at 13.2-100 Hz on panel mounting 1 mm at 5-13.2 Hz on panel mounting 1 mm at 5-13.2 Hz on symmetrical rail 3 gn at 8.7-150 Hz on symmetrical rail |
ENVIRONMENTAL | |
Storage Altitude | 0-3000 m |
OTHER | |
Poles Description | Profibus DP communication module |