RM35JA31MW - Modular 1-phase Current Control Relay, 5 A, 2 CO, 2…500 MA, , 24…240 V AC/DC
Schneider
SKU
SE_RM35JA31MW
Model
RM35JA31MW
Obsolete
Short description of RM35JA31MW
RM35JA31MW. OC OR UC RELAY 2..500MA 24-240VAC/DC
Obsolete
current control relay RM35-J
-  range 2..500 mA.
Label :  Zelio Control
-  range of product :  Zelio Control
-  minimum switching current :  10 mA at 5 V DC
-  maximum switching current :  5 A AC
-  maximum power consumption in VA :  3.5 VA AC
-  product or component type :  modular measurement and control relays
-  measurement range :  10...100 mA E2-M terminals, 2...20 mA E1-M terminals, 2...500 mA current, 50...500 mA E3-M terminals
-  relay type :  current control relay
-  relay name :  RM35JA
-  relay monitored parameters :  overcurrent or undercurrent in window mode,overcurrent or undercurrent detection
-  time delay type :  adjustable 1...20 s, 0 + 10 % on energisation Ti, adjustable 0.3...30 s, 0 + 10 % on crossing the threshold Tt
-  utilisation category :  AC
- 12 conforming to IEC 60947-5-1, AC
- 13 conforming to IEC 60947-5-1, AC
- 14 conforming to IEC 60947-5-1, AC
- 15 conforming to IEC 60947-5-1, DC
- 12 conforming to IEC 60947-5-1, DC
- 13 conforming to IEC 60947-5-1, DC
- 14 conforming to IEC 60947-5-1
-  switching capacity in VA :  1250 VA
-  Range Presentation :  They can monitor power supplies (phases, voltage, current, frequency) to protect motors and other equipment or control physical values such as level, speed and temperature.
-  Phase control relay Detects all possible faults occurring in the phases
-  Voltage & current control relays Ensure your equipment is powered with proper values
-  Frequency control relay Monitors frequency variation from your power generation set
-  Level control relay Filling or emptying, adapts to all kinds of materials
-  Pump control relay Controls and protects your pump from dry running or overloading
-  Speed control relay Picks up the improper rhythm of your process
-  Temperature control relay for lift application Dedicated to lift temperature monitoring (EN81)
-  Temperature control relays Dedicated to temperature regulation (heating, cooling or heating/cooling of processes)
-  Range Benefits :  Monitoring of your equipmentSimple and accurate adjustments are a sure-fire way to achieve quick and easy setup. These relays can satisfy all the monitoring requirements of mobile process control or network equipment.
-  Range Application Presentation : 
-  Industry and domestic :  switchboards in simple machines, motors and process monitoring
-  Start-up and monitoring of water treatment equipment
-  Packaging, textile, HVAC
-  range 2..500 mA.
Label :  Zelio Control
-  range of product :  Zelio Control
-  minimum switching current :  10 mA at 5 V DC
-  maximum switching current :  5 A AC
-  maximum power consumption in VA :  3.5 VA AC
-  product or component type :  modular measurement and control relays
-  measurement range :  10...100 mA E2-M terminals, 2...20 mA E1-M terminals, 2...500 mA current, 50...500 mA E3-M terminals
-  relay type :  current control relay
-  relay name :  RM35JA
-  relay monitored parameters :  overcurrent or undercurrent in window mode,overcurrent or undercurrent detection
-  time delay type :  adjustable 1...20 s, 0 + 10 % on energisation Ti, adjustable 0.3...30 s, 0 + 10 % on crossing the threshold Tt
-  utilisation category :  AC
- 12 conforming to IEC 60947-5-1, AC
- 13 conforming to IEC 60947-5-1, AC
- 14 conforming to IEC 60947-5-1, AC
- 15 conforming to IEC 60947-5-1, DC
- 12 conforming to IEC 60947-5-1, DC
- 13 conforming to IEC 60947-5-1, DC
- 14 conforming to IEC 60947-5-1
-  switching capacity in VA :  1250 VA
-  Range Presentation :  They can monitor power supplies (phases, voltage, current, frequency) to protect motors and other equipment or control physical values such as level, speed and temperature.
-  Phase control relay Detects all possible faults occurring in the phases
-  Voltage & current control relays Ensure your equipment is powered with proper values
-  Frequency control relay Monitors frequency variation from your power generation set
-  Level control relay Filling or emptying, adapts to all kinds of materials
-  Pump control relay Controls and protects your pump from dry running or overloading
-  Speed control relay Picks up the improper rhythm of your process
-  Temperature control relay for lift application Dedicated to lift temperature monitoring (EN81)
-  Temperature control relays Dedicated to temperature regulation (heating, cooling or heating/cooling of processes)
-  Range Benefits :  Monitoring of your equipmentSimple and accurate adjustments are a sure-fire way to achieve quick and easy setup. These relays can satisfy all the monitoring requirements of mobile process control or network equipment.
-  Range Application Presentation : 
-  Industry and domestic :  switchboards in simple machines, motors and process monitoring
-  Start-up and monitoring of water treatment equipment
-  Packaging, textile, HVAC
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24...240 V AC/DC 50/60 Hz +/- 10 % |
Contacts Type And Composition | 2 C/O |
Discrete Input Number | 2 C/O |
Measurement Accuracy | +/- 10 % of the full scale value |
Product Or Component Type | current control relay |
Range Of Product | Harmony Control Relays |
[Uc] Control Circuit Voltage | 24...240 V |
Control Circuit Frequency | 40...70 Hz +/- 10 % |
EAN13 | 3389119405218 |
Measurement Range | 10...100 mA E2-M terminals 2...20 mA E1-M terminals 2...500 mA current 50...500 mA E3-M terminals |
Mounting Support | 35 mm symmetrical DIN rail conforming to EN/IEC 60715 |
Range Name | Zelio Control |
Relay Monitored Parameters | overcurrent or undercurrent detection overcurrent or undercurrent in window mode |
Relay Name | RM35JA |
Relay Type | current control relay |
Time Delay Type | adjustable 0.3...30 s, 0 + 10 % on crossing the threshold Tt adjustable 1...20 s, 0 + 10 % on energisation Ti |
Utilisation Category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1 |
COMPLEMENTARY | |
Output Contacts | 2 C/O |
System Requirements | 2 C/O |
Time Delay | +/- 10 % of the full scale value |
[In] Rated Current | 5 A |
Compatibility Code | RM3 |
Connections - Terminals | screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end screw connectors |
Contacts Material | cadmium free |
Control Circuit Voltage Limits | - 15 % + 10 % Un |
Electrical Durability | 100000 cycles |
Functionality | overcurrent or undercurrent in window mode |
Housing Material | self-extinguishing plastic |
Hysteresis | 5-50 % of threshold setting |
Immunity To Microbreaks | 50 ms |
Insulation Resistance | > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1 > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5 > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1 |
Local Signalling | LED (green) for power ON LED (yellow) for relay ON |
Marking | CE : 73/23/EEC CE : EMC 89/336/EEC |
Maximum Measuring Cycle | 30 ms measurement cycle as true rms value |
Maximum Power Consumption In VA | 3.5 VA AC |
Maximum Power Consumption In W | 0.6 W DC |
Maximum Switching Current | 5 A AC |
Maximum Switching Voltage | 250 V AC |
Measurement Error | 0.05 %/°C with temperature variation 1 by volt over the whole range with voltage variation |
Mechanical Durability | 30000000 cycles |
Minimum Switching Current | 10 mA at 5 V DC |
Net Weight | 0.13 kg |
Nominal Output Current | 5 A |
Operating Position | any position without derating |
Operating Rate | <= 360 operations/hour full load |
Polarity | no DC |
Repeat Accuracy | +/- 0.5 % for input and measurement circuit +/- 2 % for time delay |
Reset Time | 1500 ms time delay |
Resistance Across Terminals | 0.2 Ohm at E3-M terminals 1 Ohm at E2-M terminals 5 Ohm at E1-M terminals |
Run-up Delay At Power-up | 0.3 s |
Safety Reliability Data | B10d = 270000 MTTFd = 296.8 years |
Supply Voltage Limits | 20.4-264 V AC/DC |
Switching Capacity In VA | 1250 VA |
Threshold Setting | 10...100 % |
Tightening Torque | 0.6-1 N.m conforming to IEC 60947-1 |
Width | 35 mm |
[Ui] Rated Insulation Voltage | 250 V conforming to IEC 60664-1 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -20-50 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Dielectric Test Voltage | 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1 |
Electromagnetic Compatibility | emission standard for industrial environments conforming to EN/IEC 61000-6-4 emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
IP Degree Of Protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
Non-dissipating Shock Wave | 4 kV conforming to IEC 60255-5 4 kV conforming to IEC 60664-1 4 kV conforming to IEC 61000-4-5 |
Overvoltage Category | III conforming to IEC 60664-1 |
Pollution Degree | 3 conforming to IEC 60664-1 |
Product Certifications | CSA C-Tick GL GOST UL |
Relative Humidity | 95-95 % at 55-55 °C conforming to IEC 60068-2-30 |
Shock Resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
Standards | EN/IEC 60255-6 |
Vibration Resistance | 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6-150 Hz) conforming to IEC 60255-21-1 |
OTHER | |
Poles Description | current control relay |
[Us] Rated Supply Voltage | 24...240 V AC/DC 50/60 Hz +/- 10 % |