RM35ATL0MW - Temperature Control Relay RM35-A - 24..240 V AC/DC - 1 OC
Schneider
SKU
SE_RM35ATL0MW
Model
RM35ATL0MW
Obsolete
Short description of RM35ATL0MW
RM35ATL0MW. OVER UNDER TEMP 1C/O 24-240VAC/DC
Obsolete
temperature control relay RM35-A-24..240 V AC/DC-1 OC.
Label :  Zelio Control
-  range of product :  Zelio Control
-  switching capacity in VA :  1250 VA
-  minimum switching current :  10 mA at 5 V DC
-  maximum power consumption in VA :  3.5 VA AC
-  product or component type :  modular measurement and control relays
-  relay type :  temperature control relays
-  product specific application :  for elevator machine rooms and 3-phase supplies
-  relay name :  RM35AT
-  relay monitored parameters :  undertemperature- 1...11°C,overtemperature :  34...46°C
-  utilisation category :  AC
- 12 conforming to IEC 60947-5-1, AC
- 13 conforming to IEC 60947-5-1, AC
- 14 conforming to IEC 60947-5-1, AC
- 15 conforming to IEC 60947-5-1, DC
- 12 conforming to IEC 60947-5-1, DC
- 13 conforming to IEC 60947-5-1, DC
- 14 conforming to IEC 60947-5-1
-  time delay range :  0.1...10 s adjustable (tolerance :  0...10 % of the full scale value)
-  Range Presentation :  They can monitor power supplies (phases, voltage, current, frequency) to protect motors and other equipment or control physical values such as level, speed and temperature.
-  Phase control relay Detects all possible faults occurring in the phases
-  Voltage & current control relays Ensure your equipment is powered with proper values
-  Frequency control relay Monitors frequency variation from your power generation set
-  Level control relay Filling or emptying, adapts to all kinds of materials
-  Pump control relay Controls and protects your pump from dry running or overloading
-  Speed control relay Picks up the improper rhythm of your process
-  Temperature control relay for lift application Dedicated to lift temperature monitoring (EN81)
-  Temperature control relays Dedicated to temperature regulation (heating, cooling or heating/cooling of processes)
-  Range Benefits :  Monitoring of your equipmentSimple and accurate adjustments are a sure-fire way to achieve quick and easy setup. These relays can satisfy all the monitoring requirements of mobile process control or network equipment.
-  Range Application Presentation : 
-  Industry and domestic :  switchboards in simple machines, motors and process monitoring
-  Start-up and monitoring of water treatment equipment
-  Packaging, textile, HVAC
Label :  Zelio Control
-  range of product :  Zelio Control
-  switching capacity in VA :  1250 VA
-  minimum switching current :  10 mA at 5 V DC
-  maximum power consumption in VA :  3.5 VA AC
-  product or component type :  modular measurement and control relays
-  relay type :  temperature control relays
-  product specific application :  for elevator machine rooms and 3-phase supplies
-  relay name :  RM35AT
-  relay monitored parameters :  undertemperature- 1...11°C,overtemperature :  34...46°C
-  utilisation category :  AC
- 12 conforming to IEC 60947-5-1, AC
- 13 conforming to IEC 60947-5-1, AC
- 14 conforming to IEC 60947-5-1, AC
- 15 conforming to IEC 60947-5-1, DC
- 12 conforming to IEC 60947-5-1, DC
- 13 conforming to IEC 60947-5-1, DC
- 14 conforming to IEC 60947-5-1
-  time delay range :  0.1...10 s adjustable (tolerance :  0...10 % of the full scale value)
-  Range Presentation :  They can monitor power supplies (phases, voltage, current, frequency) to protect motors and other equipment or control physical values such as level, speed and temperature.
-  Phase control relay Detects all possible faults occurring in the phases
-  Voltage & current control relays Ensure your equipment is powered with proper values
-  Frequency control relay Monitors frequency variation from your power generation set
-  Level control relay Filling or emptying, adapts to all kinds of materials
-  Pump control relay Controls and protects your pump from dry running or overloading
-  Speed control relay Picks up the improper rhythm of your process
-  Temperature control relay for lift application Dedicated to lift temperature monitoring (EN81)
-  Temperature control relays Dedicated to temperature regulation (heating, cooling or heating/cooling of processes)
-  Range Benefits :  Monitoring of your equipmentSimple and accurate adjustments are a sure-fire way to achieve quick and easy setup. These relays can satisfy all the monitoring requirements of mobile process control or network equipment.
-  Range Application Presentation : 
-  Industry and domestic :  switchboards in simple machines, motors and process monitoring
-  Start-up and monitoring of water treatment equipment
-  Packaging, textile, HVAC
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24...240 V AC/DC |
Contacts Type And Composition | 1 C/O |
Discrete Input Number | 1 C/O |
Measurement Accuracy | +/- 2 °C |
Product Or Component Type | temperature control relay |
Range Of Product | Harmony Control Relays |
Thread Type | 0.1...10 s adjustable delay (tolerance: 0...10 % of the full scale value) |
[Uc] Control Circuit Voltage | 24...240 V |
EAN13 | 3389119405164 |
Mounting Support | 35 mm symmetrical DIN rail conforming to EN/IEC 60715 |
Product Specific Application | for elevator machine rooms and 3-phase supplies |
Range Name | Zelio Control |
Relay Monitored Parameters | overtemperature: 34...46°C undertemperature: -1...11°C |
Relay Name | RM35AT |
Relay Type | temperature control relays |
Utilisation Category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1 |
COMPLEMENTARY | |
Output Contacts | 1 C/O |
System Requirements | 1 C/O |
Time Delay | +/- 2 °C |
Time Delay Range | 0.1...10 s adjustable delay (tolerance: 0...10 % of the full scale value) |
[In] Rated Current | 5 A |
Compatibility Code | RM3 |
Connections - Terminals | screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end screw connectors |
Contacts Material | cadmium free |
Control Circuit Voltage Limits | - 10 % + 10 % Un DC - 15 % + 10 % Un AC |
Electrical Durability | 100000 cycles |
Housing Material | self-extinguishing plastic |
Immunity To Microbreaks | 10 ms |
Installed Device | Pt 100 probe cable length <= 10 m |
Insulation | galvanic insulation between supply and measurement |
Insulation Resistance | > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1 > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5 > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1 |
Marking | CE : 73/23/EEC CE : EMC 89/336/EEC |
Maximum Power Consumption In VA | 3.5 VA AC |
Maximum Power Consumption In W | 0.6 W DC |
Maximum Switching Voltage | 250 V AC/DC |
Mechanical Durability | 30000000 cycles |
Minimum Switching Current | 10 mA at 5 V DC |
Nominal Output Current | 5 A |
Operating Position | any position without derating |
Operating Rate | <= 360 operations/hour full load |
Reset Time | 8 s |
Resistance Across Terminals | 1.33 kOhm at temperature |
Response Time | <= 3.5 s (on disappearance of fault) <= 3.5 s + Tt (in case of temperature fault) |
Run-up Delay At Power-up | 0.2 s |
Status LED | 1 LED green for power ON 1 LED yellow for correct temperature (high R1) 1 LED yellow for correct temperature (low R2) |
Supply Frequency | 50/60 Hz +/- 10 % |
Supply Voltage Limits | 20.4-264 V AC 21.6-264 V DC |
Switching Capacity In VA | 1250 VA |
Temperature Probe Type | Pt 100 - 3-wire |
Tightening Torque | 0.6-1 N.m conforming to IEC 60947-1 |
Width | 35 mm |
[Ui] Rated Insulation Voltage | 250 V conforming to IEC 60664-1 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -20-50 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Dielectric Test Voltage | 2 kV, 1 min AC 50 Hz |
Electromagnetic Compatibility | emission standard for industrial environments conforming to EN/IEC 61000-6-4 emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 immunity for industrial environments conforming to NF EN/IEC 61000-6-2 |
IP Degree Of Protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
Non-dissipating Shock Wave | 4 kV |
Overvoltage Category | III conforming to IEC 60664-1 |
Pollution Degree | 3 conforming to IEC 60664-1 |
Product Certifications | CSA C-Tick GL GOST UL |
Shock Resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
Standards | IEC 60255-6 NF EN 60255-6 |
Vibration Resistance | 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 1 gn (f= 57.6-150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 |
OTHER | |
Poles Description | temperature control relay |
[Us] Rated Supply Voltage | 24...240 V AC/DC |