RM17TA00 - Multifunction Control Relay RM17-TA - Range 183..528 V AC
Schneider
SKU
SE_RM17TA00
Model
RM17TA00
Obsolete
Short description of RM17TA00
RM17TA00. PH ROT:FAILURE 208-480VAC ASYMM
Obsolete
multifunction control relay RM17-TA
-  range 183..528 V AC.
Label :  Zelio Control
-  range of product :  Zelio Control
-  switching capacity in VA :  1250 VA
-  product or component type :  modular measurement and control relays
-  measurement range :  208...480 V voltage AC
-  relay type :  multifunction control relay
-  product specific application :  for 3-phase supply
-  relay name :  RM17TA
-  relay monitored parameters :  asymmetry,phase sequence,phase failure detection
-  time delay type :  adjustable 0.1...10 s, +/- 10 % of the full scale value
-  Range Presentation :  They can monitor power supplies (phases, voltage, current, frequency) to protect motors and other equipment or control physical values such as level, speed and temperature.
-  Phase control relay Detects all possible faults occurring in the phases
-  Voltage & current control relays Ensure your equipment is powered with proper values
-  Frequency control relay Monitors frequency variation from your power generation set
-  Level control relay Filling or emptying, adapts to all kinds of materials
-  Pump control relay Controls and protects your pump from dry running or overloading
-  Speed control relay Picks up the improper rhythm of your process
-  Temperature control relay for lift application Dedicated to lift temperature monitoring (EN81)
-  Temperature control relays Dedicated to temperature regulation (heating, cooling or heating/cooling of processes)
-  Range Benefits :  Monitoring of your equipmentSimple and accurate adjustments are a sure-fire way to achieve quick and easy setup. These relays can satisfy all the monitoring requirements of mobile process control or network equipment.
-  Range Application Presentation : 
-  Industry and domestic :  switchboards in simple machines, motors and process monitoring
-  Start-up and monitoring of water treatment equipment
-  Packaging, textile, HVAC
-  range 183..528 V AC.
Label :  Zelio Control
-  range of product :  Zelio Control
-  switching capacity in VA :  1250 VA
-  product or component type :  modular measurement and control relays
-  measurement range :  208...480 V voltage AC
-  relay type :  multifunction control relay
-  product specific application :  for 3-phase supply
-  relay name :  RM17TA
-  relay monitored parameters :  asymmetry,phase sequence,phase failure detection
-  time delay type :  adjustable 0.1...10 s, +/- 10 % of the full scale value
-  Range Presentation :  They can monitor power supplies (phases, voltage, current, frequency) to protect motors and other equipment or control physical values such as level, speed and temperature.
-  Phase control relay Detects all possible faults occurring in the phases
-  Voltage & current control relays Ensure your equipment is powered with proper values
-  Frequency control relay Monitors frequency variation from your power generation set
-  Level control relay Filling or emptying, adapts to all kinds of materials
-  Pump control relay Controls and protects your pump from dry running or overloading
-  Speed control relay Picks up the improper rhythm of your process
-  Temperature control relay for lift application Dedicated to lift temperature monitoring (EN81)
-  Temperature control relays Dedicated to temperature regulation (heating, cooling or heating/cooling of processes)
-  Range Benefits :  Monitoring of your equipmentSimple and accurate adjustments are a sure-fire way to achieve quick and easy setup. These relays can satisfy all the monitoring requirements of mobile process control or network equipment.
-  Range Application Presentation : 
-  Industry and domestic :  switchboards in simple machines, motors and process monitoring
-  Start-up and monitoring of water treatment equipment
-  Packaging, textile, HVAC
MAIN SPECIFICATIONS | |
---|---|
Contacts Type And Composition | 1 C/O |
Discrete Input Number | 1 C/O |
Product Or Component Type | 3-phase control relay |
Range Of Product | Harmony Control Relays |
[Uc] Control Circuit Voltage | 208...480 V |
Control Circuit Frequency | 50...60 Hz +/- 10 % |
EAN13 | 3389119405041 |
Measurement Range | 208...480 V voltage AC |
Mounting Support | 35 mm symmetrical DIN rail conforming to EN/IEC 60715 |
Product Specific Application | for 3-phase supply |
Range Name | Zelio Control |
Relay Monitored Parameters | asymmetry phase failure detection phase sequence |
Relay Name | RM17TA |
Relay Type | multifunction control relay |
Time Delay Type | adjustable 0.1...10 s, +/- 10 % of the full scale value |
Utilisation Category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 |
COMPLEMENTARY | |
Output Contacts | 1 C/O |
System Requirements | 1 C/O |
[In] Rated Current | 5 A |
Adjustment Of Asymmetry Threshold | 5...15 % of Un selected |
Compatibility Code | RM17 |
Connections - Terminals | screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end screw connectors |
Control Circuit Voltage Limits | - 12 % + 10 % Un |
Electrical Durability | 100000 cycles |
Functionality | asymmetry |
Housing Material | self-extinguishing plastic |
Hysteresis | 2-2 % |
Insulation Resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 |
Local Signalling | LED (green) for power ON LED (yellow) for relay ON |
Marking | CE |
Maximum Measuring Cycle | 150 ms measurement cycle as true rms value |
Maximum Switching Current | 5 A AC 5 A DC |
Maximum Switching Voltage | 250 V AC 250 V DC |
Measurement Error | < 0.05 %/°C with temperature variation < 1 % over the whole range with voltage variation |
Measurement Voltage Limits | 183-528 V AC |
Mechanical Durability | 30000000 cycles |
Minimum Switching Current | 10 mA at 5 V DC |
Net Weight | 0.13 kg |
Nominal Output Current | 5 A |
Operating Position | any position without derating |
Operating Rate | <= 360 operations/hour full load |
Phase Failure Sensitivity | 0.7 Un |
Power Consumption In VA | 0-22 VA at 400 V AC 50 Hz |
Repeat Accuracy | 0.5 % for input and measurement circuit 3 % for time delay |
Reset Time | 1500 ms time delay |
Response Time | < 200 ms (in the event of a fault) |
Run-up Delay At Power-up | 650 ms |
Safety Reliability Data | B10d = 470000 MTTFd = 502.2 years |
Supply Frequency | 50/60 Hz +/- 10 % |
Supply Voltage Limits | 183-528 V AC |
Switching Capacity In VA | 1250 VA |
Threshold Adjustment Voltage | +2...+17 % in the range 480 V AC -2...-12 % in the range 208 V AC -2...-17 % in the range 220 V AC 2...20 % of Un selected |
Tightening Torque | 0.6-1 N.m conforming to IEC 60947-1 |
Voltage Range | 208...480 V phase to phase |
Width | 17.5 mm |
[Ui] Rated Insulation Voltage | 400 V conforming to IEC 60664-1 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -20-50 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Dielectric Test Voltage | 2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1 |
Directives | 73/23/EEC - low voltage directive 89/336/EEC - electromagnetic compatibility |
Electromagnetic Compatibility | emission standard for industrial environments conforming to EN/IEC 61000-6-4 emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 immunity for industrial environments conforming to EN/IEC 61000-6-2 |
IP Degree Of Protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
Non-dissipating Shock Wave | 4 kV conforming to IEC 60255-5 4 kV conforming to IEC 60664-1 4 kV conforming to IEC 61000-4-5 |
Overvoltage Category | III conforming to IEC 60664-1 |
Pollution Degree | 3 conforming to IEC 60664-1 |
Product Certifications | CSA C-Tick GL GOST UL |
Relative Humidity | 95-95 % at 55-55 °C conforming to IEC 60068-2-30 |
Shock Resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
Standards | EN/IEC 60255-1 |
Vibration Resistance | 0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6-150 Hz) conforming to IEC 60255-21-1 |
OTHER | |
Poles Description | 3-phase control relay |
[Us] Rated Supply Voltage | Harmony Control Relays |