REL50456 - Easergy P5M30 48-250V 3CT 1CSH 4VT 10DI-8DO RSTP Eth RJ45
Schneider
SKU
SE_REL50456
Model
REL50456
SGD $11,112.48 All prices inclusive of GST
Short description of REL50456
REL50456. Protection relay P5M30-AACB-HABAH-AAAA
Country of Origin
France
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 100...230 V AC 24...240 V DC |
Control Type | local/remote control programmable switchgear interlocking switchgear control and monitoring |
Display Type | and colour LCD 480 x 272 pixels |
Power Supply Output Current | embedded HTTP server |
Product Or Component Type | protection relay |
Range Of Product | Easergy P5 |
Web Server | embedded HTTP server |
[Ie] Rated Operational Current | local/remote control programmable switchgear interlocking switchgear control and monitoring |
Communication Port Protocol | DNP3 over ethernet EtherNet/IP IEC 61850 ed. 1 IEC 61850 ed. 2 Modbus TCP |
Device Short Name | P5M30-AACB-HABAH-AAAA |
Digital Input Number | 10 |
EAN13 | 3606489488055 |
Monitoring Function | circuit breaker monitoring relay self-monitoring trip circuit supervision 74 |
Mounting Case Size | 30TE |
Number Of Sensors | 0 arc sensor(s) 0 temperature sensor(s) |
Range Name | Easergy Series P5 |
Redundancy Communication Port Protocol | RSTP |
Relay Application | motor |
Single Line Diagram | 6 controlled + 2 monitored objects |
Switchgear Diagnosis Type | CT/VT supervision ANSI code: 60 trip circuit supervision ANSI code: 74 |
Type Of Measurement | current 2nd, 15th harmonics with THD current 3-phase current negative sequence current positive sequence current ratio of negative and positive current zero sequence frequency phasor diagram of currents or voltages voltage 3-phase voltage negative sequence voltage positive sequence voltage residual voltage zero sequence |
COMPLEMENTARY | |
Analogue Output Number | and colour LCD 480 x 272 pixels |
Connections - Terminals | ring lugs (analog inputs and outputs) screw (digital input/output) |
Cybersecurity | client IP address filter firmware signature password protection port hardening secured communication with assciated tools |
Depth | 219 mm |
Device Mounting | flush |
Height | 176 mm |
Input Type | : 1/5 A CT phase current 3 : CSH residual current 1 : VT voltage 4 |
Integrated Connection Type | extension port 1 rear with backup memory RJ45 2 rear USB port 2 front |
Local Signalling | 10 x LED tri-colour programmable 4 x LED |
Mechanical Robustness | earthquakes (level: class 2) conforming to IEC 60255-21-3 shocks (level: class 2) conforming to IEC 60255-21-2 vibrations (level: class 2) conforming to IEC 60255-21-1 vibrations conforming to GOST 17516.1 vibrations conforming to IACS E10 |
Mounting Mode | withdrawable |
Net Weight | 3.5 kg |
Network And Machine Diagnosis Type | disturbance recording event recording relay maintenance tripping context |
Number Of Key | 7 customizable |
Number Of Outputs | 1 watchdog 7 DO |
Protection Type | breaker failure 50BF broken conductor 46 I2/I1 cold load pick-up CT supervision 60 current unbalance 46 I2/I1 directional active underpower 37P directional earth fault 67N directional phase overcurrent 67 earth fault overcurrent 50N/51N earth fault overvoltage 59N earth fault wattmetric 32N excessive starting time, locked rotor 48/51LR H2 detection H5 detection lockout relay 86 motor restart inhibition 66 negative sequence overcurrent 46 neutral admittance 21YN overvoltage 59 phase overcurrent 50/51 phase undercurrent 37 positive sequence undervoltage 27P programmable curve programmable logic programmable stages 99 switch ON to fault (SOTF) transient earth fault 67NI underfrequency 81/81N undervoltage 27 VT supervision 60 |
Setting | 4 |
Software Name | EcoStruxure Power Device eSetup Easergy Pro: virtual simulation test |
Time Synchronisation Protocol | SNTP |
Width | 152 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -40-70 °C ( 96 h ) -40-85 °C ( 16 h ) |
Ambient Air Temperature For Storage | -40-85 °C |
Electromagnetic Compatibility | EMC immunity class 4 conforming to ANSI C37.90.3 EMC immunity class 4 conforming to IEC 61000-4-2 EMC immunity conforming to ANSI C37.90.1 EMC immunity conforming to ANSI C37.90.2 EMC immunity conforming to GOST 30804.4.12 EMC immunity conforming to GOST 30804.4.3 EMC immunity conforming to GOST 32137 EMC immunity conforming to IACS E10 EMC immunity conforming to IEC 61000-4-12 EMC immunity level 3 conforming to IEC 61000-4-18 EMC immunity level 3 conforming to IEC 61000-4-3 EMC immunity level 3 conforming to IEC 61000-4-6 EMC immunity level 4 conforming to IEC 61000-4-16 EMC immunity level 4 conforming to IEC 61000-4-4 EMC immunity level 4 conforming to IEC 61000-4-5 EMC immunity level 5 conforming to IEC 61000-4-10 EMC immunity level 5 conforming to IEC 61000-4-8 EMC immunity level 5 conforming to IEC 61000-4-9 emission tests class A conforming to CISPR 11 emission tests class A conforming to CISPR 22 emission tests conforming to IACS E10 |
Environmental Characteristic | exposure to cold conforming to IEC 60068-2-1 exposure to damp heat in service conforming to IEC 60068-2-30 exposure to damp heat in service conforming to IEC 60068-2-78 exposure to dry heat conforming to IEC 60068-2-2 influence of corrosion/gas test 2 conforming to IEC 60068-2-60 influence of corrosion/gas test 2 conforming to IEC 60721-3-3 influence of corrosion/gas test 4 conforming to IEC 60068-2-60 influence of corrosion/gas test 4 conforming to IEC 60721-3-3 salt mist conforming to IEC 60068-2-52 temperature variation conforming to IEC 60068-2-14 |
IP Degree Of Protection | IP54 conforming to IEC 60529 |
Operating Altitude | 2000 m |
Protective Treatment | conformal coating conforming to IEC 60068-2-52:Kb/1 conformal coating conforming to IEC 60068-2-60:Ke conformal coating conforming to IEC 60721-3-3:3C2 |
Relative Humidity | 0-93 % at 40-40 °C, without condensation, 56 days 93-95 % at 25-55 °C, 6 cycles, 12 + 12 hours |
OTHER | |
Poles Description | protection relay |
[Us] Rated Supply Voltage | 100...230 V AC 24...240 V DC |
Write Your Own Review