RE22R2QEMR - Harmony, Modular Timing Relay, 8 A, 2 CO, 0.3 S…30 S, Star Delta, 24...240 V AC/DC.
Short description of RE22R2QEMR
This Harmony RE22 modular single function timer can be set between 1 seconds and 300 hours. It provides function Qe and it is mountable on DIN rail. This modular single function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Selectable timing range offers a one stop solution for your power management system. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC.
-  product or component type : Single function relay
-  discrete output type : Relay
-  device short name : RE22
-  nominal output current : 8 A
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 24...240 V AC/DC 50/60 Hz |
Contacts Type And Composition | 2 C/O 2 C/O timed contact, cadmium free 2 C/O |
Control Type | diagnostic button rotary knob |
Discrete Input Number | 2 C/O 2 C/O timed contact, cadmium free 2 C/O |
Discrete Output Type | relay |
Product Or Component Type | single function relay |
Range Of Product | Harmony Timer Relays |
Rated Power In W | <= 2.4 V |
Thread Type | 0.3...30 s |
[Ie] Rated Operational Current | diagnostic button rotary knob |
[Uc] Control Circuit Voltage | 24...240 V |
Device Short Name | RE22 |
Mounting Support | 35 mm DIN rail conforming to EN/IEC 60715 |
Range Name | Harmony Timer Relays |
Time Delay Type | Qe star-delta |
COMPLEMENTARY | |
Input Voltage | <= 2.4 V |
Product Name | relay |
Time Delay Range | 0.3...30 s |
[Ics] Rated Service Breaking Capacity | relay |
[In] Rated Current | 5 A |
Connections - Terminals | screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end screw connectors |
Creepage Distance | 4 kV/3 conforming to IEC 60664-1 |
Electrical Durability | 100000 cycles, 2 A at 24 V, DC-1 100000 cycles, 8 A at 250 V, AC-1 |
Functionality | star-delta starter timing |
Housing Material | self-extinguishing |
Immunity To Microbreaks | 10 ms |
Insulation Resistance | 100 MOhm at 500 V DC conforming to IEC 60664-1 |
Maximum Delay Response | 100 ms |
Maximum Switching Current | 8 A |
Maximum Switching Voltage | 250 V AC |
Mechanical Durability | 10000000 cycles |
Minimum Switching Current | 10 mA at 5 V DC |
Mounting Position | any position |
Net Weight | 0.09 kg |
Nominal Output Current | 8 A |
Output Type | relay |
Power Consumption In VA | 3-3 VA at 240 V AC |
Power Consumption In W | 1.5 W at 240 V DC |
Repeat Accuracy | +/- 0.5 % conforming to IEC 61812-1 |
Reset Time | 120 ms on de-energisation |
Safety Reliability Data | B10d = 320000 MTTFd = 353.8 years |
Setting Accuracy Of Time Delay | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 |
Status LED | LED backlight green (steady) for dial pointer indication LED yellow (fast flashing) for timing in progress and output relay de-energised LED yellow (slow flashing) for timing in progress and output relay energised LED yellow (steady) for output relay energised |
Supply Frequency | 50...60 Hz +/- 5 % |
Switching Capacity In VA | 2000 VA |
Temperature Drift | +/- 0.05 %/°C |
Tightening Torque | 0.6-1 N.m conforming to IEC 60947-1 |
Voltage Drift | +/- 0.2 %/V |
Voltage Range | 0.85...1.1 Us |
Width | 22.5 mm |
[Uimp] Rated Impulse Withstand Voltage | 5 kV for 1.2-50 µs conforming to IEC 60664-1 |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -20-60 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Dielectric Strength | 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1 |
Directives | 2004/108/EC - electromagnetic compatibility 2006/95/EC - low voltage directive |
Electromagnetic Compatibility | conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11 immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 |
IP Degree Of Protection | IP20 terminals: conforming to IEC 60529 IP40 housing: conforming to IEC 60529 IP50 front panel: conforming to IEC 60529 |
Overvoltage Category | III conforming to IEC 60664-1 |
Pollution Degree | 3 conforming to IEC 60664-1 |
Product Certifications | CCC CE CSA EAC GL RCM UL |
Relative Humidity | 95-95 % at 25-55 °C |
Shock Resistance | 15 gn not operating for 11 ms conforming to IEC 60068-2-27 5 gn in operation for 11 ms conforming to IEC 60068-2-27 |
Standards | IEC 61812-1 UL 508 |
Vibration Resistance | 20 m/s² (f= 10-150 Hz) conforming to IEC 60068-2-6 |
OTHER | |
Poles Description | single function relay |
[Us] Rated Supply Voltage | 24...240 V AC/DC 50/60 Hz |