PAS600 EcoStruxure Panel Server - universal wireless, concentrator modbus gateway 110-277 VAC/DC
Schneider
SKU
SE_PAS600
Model
PAS600
SGD $1,507.80 All prices inclusive of GST
Country of Origin
India
PAS600 - EcoStruxure Panel Server is a gateway, providing connection of wired or unwired smart IoT devices to edge control software or cloud application.
Connect wireless devices from Schneider Electric such as PowerTag Energy, PowerLogic HeatTag, Power Tag Ambiant, Power Tag control and others.
Connect most of Modbus/RS485 and Modbus/TCP devices from the market including PowerMeters and Protection devices from Schenider Electric.
User friendly web-pages offer first-lelvel of monitoring of measurements of all the conected devices including log of all alarms.
Simple troubleshooting or the sytem through embedded web-pages with advanced diagnostic informations and logs .
Easy commissioning through embedded web-pages or with EcoStruxure Power Commissionig that will offer commissioning reports and advanced features.
Product dimensions are as follows: width 71,8 millimetres, depth 70,2 millimetres and height 85 millimetres.
From 110 to 277 VAC/DC 50-60Hz 3W/10VA Max Power Supply. -25°C to +70°C Operating temperature. 5-95% relative humidity.
Major certifications including CE, UL/CSA, IEC61010, UL61010, IEC61974-1, Marine certification, IEC61443-4-2, RCM, EAC and UKCA.
The gateway can be DIN rail mounted in a modular enclosure. It has IP20 connectors, IM40 front face nose and IP30 on others faces.
Two 10/100 Base-T ethernet RJ45 connectors. Modbus RS485 open-style connector.
One connector for external Wi-Fi/Bluetooth antenna.
Direct cellular connection through external LTE router connected through Ethernet or Wi-Fi.
Perfect fit for EcoStruxure Edge Software such as Power Monitoring Expert, Power Operations and EcoStruxure Building Operations.
Designed for EcoStruxure Cloud Applications such as Facility Expert, Asset Advisor and Resource Advisor.
Connect wireless devices from Schneider Electric such as PowerTag Energy, PowerLogic HeatTag, Power Tag Ambiant, Power Tag control and others.
Connect most of Modbus/RS485 and Modbus/TCP devices from the market including PowerMeters and Protection devices from Schenider Electric.
User friendly web-pages offer first-lelvel of monitoring of measurements of all the conected devices including log of all alarms.
Simple troubleshooting or the sytem through embedded web-pages with advanced diagnostic informations and logs .
Easy commissioning through embedded web-pages or with EcoStruxure Power Commissionig that will offer commissioning reports and advanced features.
Product dimensions are as follows: width 71,8 millimetres, depth 70,2 millimetres and height 85 millimetres.
From 110 to 277 VAC/DC 50-60Hz 3W/10VA Max Power Supply. -25°C to +70°C Operating temperature. 5-95% relative humidity.
Major certifications including CE, UL/CSA, IEC61010, UL61010, IEC61974-1, Marine certification, IEC61443-4-2, RCM, EAC and UKCA.
The gateway can be DIN rail mounted in a modular enclosure. It has IP20 connectors, IM40 front face nose and IP30 on others faces.
Two 10/100 Base-T ethernet RJ45 connectors. Modbus RS485 open-style connector.
One connector for external Wi-Fi/Bluetooth antenna.
Direct cellular connection through external LTE router connected through Ethernet or Wi-Fi.
Perfect fit for EcoStruxure Edge Software such as Power Monitoring Expert, Power Operations and EcoStruxure Building Operations.
Designed for EcoStruxure Cloud Applications such as Facility Expert, Asset Advisor and Resource Advisor.
MAIN | |
---|---|
Range | EcoStruxure |
Product Name | Panel Server Universal |
Product Or Component Type | Gateway |
Device Short Name | PAS600 |
[Us] Rated Supply Voltage | 110...277 V AC 50/60 Hz 110...277 V DC |
Communication Gateway | Ethernet TCP/IP to wireless devices Ethernet/serial |
COMPLEMENTARY | |
Maximum Power Consumption In W | 3 W 110...277 V |
Communication Network Type | Ethernet, 10/100BASE-T Wi-Fi infrastructure2.4 GHz Wi-Fi access point2.4 GHz Wireless, IEEE 802.15.4 Modbus RTU, Modbus RTU client even/odd or none parity, at 1.2...115.2 kbit/s |
Communication Port Protocol | Modbus TCP DHCP HTTPS NTP/SNTP IPv4 IPv6 TCP/IP |
Communication Port Support | 2 RJ45: ETHERNET Screw terminal block: RS485 |
Number Of Server | 32 server device(s)Modbus RTU 128 server device(s)Modbus TCP/IP 40 server device(s)wireless - mixed 85 server device(s)wireless - depending on configuration |
Number Of Clients | 64 Modbus TCP/IP |
Memory Capacity | 512 MB NAND |
Connections - Terminals | Power supply: screw terminal block (top) 1.5…2.5 mm² cable(s) Communication: screw terminal block (bottom) 0.14…1.5 mm² cable(s) |
Tightening Torque | Power supply: 0.6 N.m Communication: 0.25 N.m |
Wire Stripping Length | Power supply: 7 mm Communication: 7 mm |
Mounting Mode | Clip-on |
Mounting Support | DIN rail |
Product Certifications | CE cULus CB RCM UKCA FCC IC DNV Marine ANSI RF IACS E10 |
Standards | IEC 61010 IEC 61010-1 IEC 61010-2-201 UL 61010 UL 61010-1 UL 61010-2-201 EN 61010-1 EN 61010-2-201 CAN/CSA C22.2 No. 61010-1-12 CAN/CSA C22.2 No. 61010-2-201 IEC 62974-1 IEC 61326-1 EN 61326-1 ETSI EN 301 489-1 ETSI EN 301 489-17 EN 301-893 EN 55032 CISPR 11 ETSI EN 300 328 IEEE 802.15.4 IEEE 802.11a/b/g/n IEEE 802.3 af/at FCC CFR 47 part 15 class A EN 62311 IEC 62311 ANSI C63.10 IEC 60945 EN 62974-1 DNVGL-GC-0339 |
Depth | 70.2 mm |
Height | 93 mm |
Width | 72 mm |
Net Weight | 201 g |
Data Recording | Real time data monitoring |
Data Buffer | 1 month(s) |
Function Available | Embedded web page for configuration and upgrade Diagnosis capabilities Diagnostic report Diagnostics on communication Energy management With integrated web server Firmware update Backup/restore configuration Configurable event |
Product Specific Application | Wireless Schneider Electric devices ecosystem |
Topology | Separated Ethernet network Switched Ethernet network |
Web Services | HTTPS server SFTP publication (CSV / JSON) HTTPS publication (CSV / JSON) |
Communication Service | Device Profile for Web Services (DPWS) Modbus TCP client Modbus TCP server SNTP client DHCP client DHCP server RSTP |
Commissioning Interface | EcoStruxure Power Commission desktop EcoStruxure Power Commission Mobile (through Wi-Fi Access point) EcoStruxure Power Commission web (for third party device integration) Web page |
Realtime Clock | With RTC-battery set With user calibration |
Time Synchronisation Protocol | NTP SNTP |
Range Compatibility | EcoStruxure Facility Expert EcoStruxure Building Operation EcoStruxure Power Operation EcoStruxure Power Monitoring Expert EcoStruxure Asset Advisor EcoStruxure Energy Hub EcoStruxure Resource Advisor Third party SCADA |
ENVIRONMENT | |
Relative Humidity | 0…93 % |
IP Degree Of Protection | IP40 (front face) IP20 (casing) |
Ambient Air Temperature For Operation | -25…70 °C |
Ambient Air Temperature For Storage | -40…85 °C |
Pollution Degree | 2 |
Operating Altitude | < 2300 m |
PACKING UNITS | |
Unit Type Of Package 1 | PCE |
Number Of Units In Package 1 | 1 |
Package 1 Height | 9.000 cm |
Package 1 Width | 9.000 cm |
Package 1 Length | 11.000 cm |
Package 1 Weight | 282.000 g |
Unit Type Of Package 2 | S03 |
Number Of Units In Package 2 | 27 |
Package 2 Height | 30.000 cm |
Package 2 Width | 30.000 cm |
Package 2 Length | 40.000 cm |
Package 2 Weight | 8.275 kg |