METSEPM8243 - PowerLogic PM8000 - PM8243 DIN Rail Mount Meter - Intermediate Metering.
Schneider
SKU
SE_METSEPM8243
Model
METSEPM8243
SGD $5,727.69 All prices inclusive of GST
Short description of METSEPM8243
METSEPM8243. Simplifying power quality, maximizing versatility
Country of Origin
Canada
range : PowerLogic
-  product name : PowerLogic PM8000
-  device short name : PM8243
-  product or component type : Power meter
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
-  product name : PowerLogic PM8000
-  device short name : PM8243
-  product or component type : Power meter
This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS | |
---|---|
Analogue Input Number | 110...415 V DC +/- 10 % 90...415 V AC 45...65 Hz +/- 10 % |
Contacts Type And Composition | 1 A 10 A 5 A |
Control Type | 1P + N 3P 3P + N |
Display Type | without display |
Measurement Accuracy | active energy +/- 0.2 % current +/- 0.1 % voltage +/- 0.1 % |
Mounting Diameter | 3 digital 30 V AC 3 digital 60 V DC |
Product Or Component Type | power meter |
Web Server | 512 MB |
[Uc] Control Circuit Voltage | IPv6 (internet protocol) |
Communication Port Protocol | DNP3 Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s IEC 61850 ION at 115 kbauds - 2-wire Modbus RTU at 115 kbauds - 2-wire Modbus TCP/IP RSTP 801.1d 2004 |
Device Short Name | PM8243 |
Mounting Support | DIN rail |
Power Quality Analysis | conforming to EN 50160: 2010 compliance report conforming to IEC 61000-4-30: class S power quality measurement conforming to IEC 62586 power quality monitoring conforming to IEEE 519: 2014 compliance report harmonic distortion programmablity (logic and math functions) up to the 63rd harmonic voltage sag and swell detection waveform capture |
Range | PowerLogic |
Range Name | PowerLogic PM8000 series |
Type Of Measurement | active and reactive power per phase, rms active and reactive power total apparent power per phase, rms apparent power total current frequency power factor per phase, rms power factor total voltage |
COMPLEMENTARY | |
Analogue Input Type | current (impedance 0.3 mOhm) voltage (impedance 5 MOhm) |
Analogue Output Number | without display |
Communication Network Type | IPv6 (internet protocol) |
Memory Capacity | 512 MB |
Number Of Inputs | 3 digital 30 V AC 3 digital 60 V DC |
Output Voltage | current (impedance 0.3 mOhm) voltage (impedance 5 MOhm) |
Product Name | PowerLogic PM8000 |
Time Delay | active energy +/- 0.2 % current +/- 0.1 % voltage +/- 0.1 % |
[In] Rated Current | 1 A 10 A 5 A |
Accuracy Class | class 0.2 active energy conforming to ANSI C12.20 class 0.2 active power conforming to IEC 61557-12 class 0.2 current conforming to IEC 61557-12 class 0.2 voltage conforming to IEC 61557-12 class 0.2S active energy conforming to IEC 62053-22 class 0.5 power factor conforming to IEC 61557-12 class 0.5S reactive energy conforming to IEC 62053-24 |
Communication Port Support | Ethernet screw terminal block: RS485 |
Communication Service | DHCP NTP time synchronization PTP time synchronization RSTP support SMTP e-mail notification |
Compatibility Code | PM8243 |
Cybersecurity | enable/disable communication ports password protection port hardening robust security logs Syslog protocol support |
Data Recording | alarm logs data logs event logs GPS synchronisation harmonics logs min/max of instantaneous values sag and swell logs sequence of event recording time stamping trending/forecasting waveform logs |
Depth | 90.8 mm |
Device Application | power monitoring WAGES metering |
Frequency Measurement Range | 42-69 Hz |
Height | 90.5 mm |
Information Displayed | current energy consumption frequency harmonic distortion power voltage |
Isolation Voltage | III347-600 V conforming to CSA C22.2 No 61010-1:ed. 3 III347-600 V conforming to UL 61010-1:ed. 3 III400-690 V conforming to EN 61010-1:ed. 3 III400-690 V conforming to IEC 61010-1:ed. 3 |
Market Segment | buildings large building cost management: billing: sub feeder buildings large building network management: main incomer buildings large building network management: sub feeder buildings medium building network management: main incomer buildings multi-site network management: main incomer buildings multi-site network management: sub feeder buildings small building network management: main incomer data center network management: main incomer data center network management: sub feeder healthcare network management: main incomer healthcare network management: sub feeder industry network management: main incomer industry network management: sub feeder utility: sub feeder |
Measurement Current | 50-10000 mA |
Measurement Voltage | 100-690 V AC 42...69 Hz between phases 57-400 V AC 42...69 Hz between phase and neutral |
Mounting Mode | clip-on |
Net Weight | 528 g |
Network Frequency | 50 Hz 60 Hz |
Number Of Outputs | 1 pulse |
Power Consumption In VA | 18 VA at 415 V AC |
Sampling Rate | 256 samples/cycle |
Web Services | alarm notification by e-mail customizable home page file upload/download via FTP file upload/download via SFTP HTTPS server viewing of captured waveform (FTP) viewing of captured waveform (web) web server |
Width | 90.5 mm |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -40-85 °C |
Electromagnetic Compatibility | conducted and radiated emissions conforming to EN 55011 conducted and radiated emissions conforming to EN 55022 conducted and radiated emissions conforming to FCC part 15 conducted and radiated emissions conforming to ICES-003 conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579 conducted RF disturbances conforming to IEC 61000-4-6 electrical fast transient/burst immunity test conforming to IEC 61000-4-4 electrostatic discharge conforming to IEC 61000-4-2 immunity to impulse waves conforming to IEC 61000-4-12 magnetic field at power frequency conforming to IEC 61000-4-8 radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 surge immunity test conforming to IEC 61000-4-5 surge withstand conforming to IEEE C37.90.1 voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
Installation Category | III |
IP Degree Of Protection | IP30 conforming to IEC 60529 |
Operating Altitude | 3000 m |
Product Certifications | CE cULus N998 |
Relative Humidity | 5-95 % |
Standards | IEC 61326-1 IEC 61557-12 IEC 62052-11 IEC 62053-22 IEC 62053-24 IEC 62586-2 IEEE 1588 |
OTHER | |
Poles Description | 1P + N 3P 3P + N |
[Us] Rated Supply Voltage | 110...415 V DC +/- 10 % 90...415 V AC 45...65 Hz +/- 10 % |