METSEION92040 - PowerLogic™ ION9000 Meter, DIN Mount, 192 Mm Display, B2B Adapter, HW Kit

Schneider
SKU
SE_METSEION92040
Model
METSEION92040
SGD $14,553.79 All prices inclusive of GST

Short description of METSEION92040

METSEION92040. ION9000 STANDARD CVM STANDARD PSU W/ RMD
Country of Origin
Mexico
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 2 Days

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

PowerLogic™ ION9200 meter, DIN mount, 192 mm display, B2B adapter, HW kit.
Label :  PowerLogic ION9000
-  range :  PowerLogic
-  metering type :  demand current I1, I2, I3, I4, I5,peak demand currents,demand power P, Q, S,peak demand power PM, QM, SM,calculated active and reactive energy (+/- W.h, +/- VAR.h)
-  product name :  PowerLogic ION9000
-  device short name :  ION92040
-  provided equipment :  remote display,remote display adapter,mounting instructions,mounting hardware
-  product or component type :  energy and power quality meter
-  device application :  power monitoring,WAGES metering,Net metering,medium voltage,high voltage
-  Range Presentation : 
As key components within an EcoStruxure Power system, ION9000 series power meters provide the flexibility and adaptability needed for today and for the IoT-enabled future. Third
- party certified Class 0.1S accuracy surpasses every key revenue metering standard, unlocking significant new savings for an innovative competitive edge. Simply open your web browser for comprehensive PQ analysis according to both EN50160 and IEEE519 standards.
Find out more
PowerLogic ION9000 series brochure
EcoXpert™ Partner ProgramOur mission is to ignite growth and enable success for our EcoXpert partners. Together we deliver best
- in
- class services and solutions to our customers. Discover EcoXpert
-  Range Benefits :  PowerLogic ION9000 meters help you with : 
-  Safety :  restore power efficiently while keeping people safe and processes operational. Ensure safe power recovery while switching utility feeds.
-  Reliability :  avoid downtime by understanding root causes of acute or chronic power events, and prevent future occurrences. Increase lifetime of equipment, mitigating effects of poor power quality.
-  Efficiency :  save money by reducing energy spend. Use actionable data to optimize operations, avoid peak demand or power factor penalties or errors in utility bills. Perform maintenance when and where it is needed.
-  Compliance :  comply with local and international energy efficiency standards. Ensure regulatory compliance to operate and protect your business. Prepare your business for future cyber security regulations.
-  Range Application Presentation :  PowerLogic ION9000 meters : 
-  Provide custom substation automation, demand and load management applications (thanks to ION programmability)
-  Quickly locate disturbances
-  Predictive maintenance
-  Breaker monitoring
-  Cost allocation
-  Monitoring ongoing operations like battery health and runtime variations
-  Help detect and prevent power incidents
-  Monitor critical loads 24x7 for peak performance and any deviations from the ideal
-  Demand control and load shedding applications
Combine with EcoStruxure Power edge control software and solutions for : 
- detailed preventative views into the electrical infrastructure
-  Advanced diagnostic information and power quality analysis
-  mitigation of unplanned downtime
-  quickly pinpoint the root cause of power system failures

This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS
Analogue Input Number110...480 V DC +/- 15 %
90...120 V AC 400 Hz +/- 10 %
90...480 V AC 45...66 Hz +/- 10 %
Breaking Capacity10/100BASE-TX 2 RJ45
Contacts Type And Composition1 A
5 A
Control Type3P + N + E
Display Typecolour touchscreen
remote LCD display
Measurement Accuracycurrent +/- 0.1 %
voltage +/- 0.1 %
Mounting Diameter8 digital 30 V AC/60 V DC
Number Of DoorsEthernet/serial
Product Or Component Typeenergy and power quality meter
Web Server2 GB
Communication Port ProtocolDHCP
DLMS
DNP3 at 2400...115200 bps - 2-wire
DNP3 TCP at 10/100 Mbit/s
DNS
Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
IEC 61850
ION at 2400...115200 bps - 2-wire
ION TCP at 10/100 Mbit/s
Modbus RTU at 2400...115200 bps - 2-wire
Modbus TCP at 10/100 Mbit/s
Degree Of ProtectionUL type 12, front
Device Short NameION92040
EAN133606481352316
Mounting SupportDIN rail meter device
door cut-out remote display
Power Quality Analysis conforming to IEC 61000-4-30: class A compliance reporting
conforming to IEEE 519 compliance reporting
conforming to IEEE 519 harmonic limit
dip, swell and transient
disturbance direction detection
EN 50160 compliance checking
half cycle data acquisition
total demand distortion
total harmonic distortion
transient detection (20 µs)
up to the 127th harmonic with software
up to the 63rd harmonic
waveform capture
RangePowerLogic
Range NameION9000
Type Of Measurementactive and reactive energy
active and reactive power per phase
active and reactive power total
apparent energy
apparent power per phase
apparent power total
current
current sags and swells
frequency
harmonic distorsion (I THD & U THD)
power factor per phase
power factor total
voltage
voltage sags and swells
COMPLEMENTARY
Analogue Input Typeexternal CT (impedance 0.3 mOhm)5 x
voltage (impedance 5 MOhm)
Analogue Output Numbercolour touchscreen
remote LCD display
Communication GatewayEthernet/serial
Display Resolution800 x 480 pixels
Memory Capacity2 GB
Number Of Inputs8 digital 30 V AC/60 V DC
Output Voltageexternal CT (impedance 0.3 mOhm)5 x
voltage (impedance 5 MOhm)
Port Ethernet10/100BASE-TX 2 RJ45
Product NamePowerLogic ION9000
Time Delaycurrent +/- 0.1 %
voltage +/- 0.1 %
[In] Rated Current1 A
5 A
Accuracy Classclass 0.1 active energy conforming to ANSI C12.20
class 0.1 active energy conforming to IEC 61557-12
class 0.1 active power conforming to IEC 61557-12
class 0.1 current conforming to IEC 61557-12
class 0.1 voltage conforming to IEC 61557-12
class 0.1S active energy conforming to IEC 62053-22
class 0.5 power factor conforming to IEC 61557-12
class 0.5S reactive energy conforming to IEC 62053-24
Communication Port SupportRS485 2 removable screw terminal block
Communication Servicecompliant reports
EcoStruxure Power Events Analysis
energy report
power quality summary
SMTP e-mail notification
SNMP
Cybersecurityenable/disable communication ports
hardware metrology lock
port hardening
robust security logs
Syslog protocol support
Data Recordingalarm logs
configuration change
continuous logging or snapshot
data logs
event logs
GPS synchronisation
min/max of instantaneous values
power outage
sequence of event recording
time stamping
trending/forecasting
user login/logout
user-definable data logs
Depth135.3 mm
Device Applicationhigh voltage
medium voltage
Net metering
power monitoring
WAGES metering
Electrical Insulation Classclass III conforming to EN/IEC 62052-11
Ethernet ServiceDevice Profile Web Services (DPWS)
DHCP client
FTP/HTTP/HTTPS
Rapid Scanning Tree Protocol (RSTP)
Frequency Measurement Range20-450 Hz
Height160 mm
Isolation VoltageIII347-600 V conforming to CSA C22.2 No 61010-1:ed. 3
III347-600 V conforming to UL 61010-1:ed. 3
III400-690 V conforming to EN 61010-1:ed. 3
Market Segmentchemical
data center
energy
healthcare
mining
pharmaceutical
semiconductor
Maximum Power Consumption In VA80 VA at 480 V AC
Measurement Current0.01-20 A
Measurement Voltage100-690 V AC 42...69 Hz between phases
57-400 V AC 42...69 Hz between phase and neutral
Metering Typecalculated active and reactive energy (+/- W.h, +/- VAR.h)
demand current I1, I2, I3, I4, I5
demand power P, Q, S
peak demand currents
peak demand power PM, QM, SM
Net Weight1.5 kg
Network Frequency50 Hz
60 Hz
Number Of Outputs2 form C relay output
4 digital
Power Consumption In VA38 VA at 480 V AC
Provided Equipmentmounting hardware
mounting instructions
remote display
remote display adapter
Ride-through Time100 ms 6 cycles at 60 Hz 120 V AC typical
1200 ms 72 cycles at 60 Hz 480 V AC typical
400 ms 24 cycles at 60 Hz 240 V AC typical
Sampling Rate1024 samples/cycle
Tamperproof Of Settingsprotected by sealable cover
Time Synchronisation ProtocolGPS
IRIG-B
NTP
PTP
SNTP
Web Servicesalarm notification by e-mail
ITIC (CBEMA) curve
NEMA motor derating curve
pass/fail report for EN 50160
pass/fail report for IEEE 519
push historical data via mail
SEMI curve
TLS 1.2
viewing of captured waveform
web page
Width160 mm
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-85 °C
Electromagnetic Compatibilityconducted and radiated emissions class B conforming to EN 55032
conducted and radiated emissions class B conforming to FCC part 15
conducted and radiated emissions class B conforming to ICES-003
conducted and radiated emissions conforming to EN 55011
electrostatic discharge immunity test conforming to IEC 61000-4-2
EMC immunity conforming to IEC 61000-6-5
EMC immunity conforming to IEC 61326-1
EMC immunity conforming to IEC 62052-11
immunity to conducted disturbances - test level: 2...150 kHz conforming to CLC/TR 50579
immunity to conducted disturbances conforming to IEC 61000-4-6
immunity to fast transients conforming to IEC 61000-4-4
immunity to impulse waves conforming to IEC 61000-4-12
immunity to magnetic fields at network frequency conforming to IEC 61000-4-8
immunity to radiated fields conforming to IEC 61000-4-3
surge immunity test conforming to IEC 61000-4-5
surge withstand conforming to ANSI C37.90.1
surge withstand conforming to IEEE C37.90.1
voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Installation CategoryIII
IP Degree Of ProtectionIP30 rear:
IP65 front:
Operating Altitude0...3000 m
Quality LabelsISO 14000
ISO 9001
Relative Humidity5-95 %
StandardsANSI C12.20
ANSI C37.90.1
IEC 61000-4-15
IEC 61000-4-30
IEC 61010-1
IEC 61326-1
IEC 61557-12
IEC 61850
IEC 62052-11
IEC 62052-31
IEC 62053-22
IEC 62053-23
IEC 62053-24
IEC 62586
UL 61010-1
OTHER
Poles Description3P + N + E
[Us] Rated Supply Voltage110...480 V DC +/- 15 %
90...120 V AC 400 Hz +/- 10 %
90...480 V AC 45...66 Hz +/- 10 %
Write Your Own Review
You're reviewing:METSEION92040 - PowerLogic™ ION9000 Meter, DIN Mount, 192 Mm Display, B2B Adapter, HW Kit
Your Rating