Micrologic 5.0 X control unit
-  for drawout Masterpact MTZ1.
Label : Masterpact MTZ
- range : Masterpact
- circuit breaker application : distribution IEC standard
- network type : AC
- trip unit name : Micrologic 5.0 X
- device short name : Micrologic 5.0 X
- trip unit technology : electronic
- trip unit protection functions : LSI
- trip unit rating : 1000-1000 A,2500-2500 A,400-400 A,4000-4000 A,800-800 A,5000-5000 A,1600-1600 A,2000-2000 A,3200-3200 A,630-630 A,1250-1250 A,6300-6300 A
- product or component type : control unit
- device application : equipment protection, monitoring and control-poles description : 4P,3P
- protected poles description : 4P 3d + OSN,3P 3d,4P 3d + N/2,4P 3d,4P 4d
- Range Presentation : The new worldwide benchmark for high current circuit breakersBuilding on the legendary performance and reliability of the Masterpact range, Masterpact MTZ circuit breakers are Future Ready. Incorporating the latest digital and communication technologies, they are key components within Schneider Electric’s Smart Panels, contributing to smart operation, power uptime and energy efficiency.Masterpact MTZ circuit breakers connect your electrical switchboard to any building and energy management system.A simple smart phone can act as the main HMI to monitor and control Masterpact MTZ, giving you maximum convenience and ease of management, even in the event of a power outage. The Micrologic X control units are customizable with additional digital modules available.The standardization of electrical switchboards remains the same with Masterpact MTZ circuit breakers keeping the same size frames, standardized auxiliaries and accessories, providing peace of mind for choice, installation, retrofit and operation.
Specifications
-  Rated current :  800 to 6300 A
-  Breaking capacity :  42 to 150 kA at 220/415 V AC
-  Voltage rating :  up to 1000 V AC
-  3 physical sizes :  Masterpact MTZ1 from 630 to 1600 A; Masterpact MTZ2 from 800 to 4000 A; Masterpact MTZ3 from 4000 to 6300 A
-  Draw out and fixed mount
-  3 pole and 4 pole construction
-  Optimized selection of 4 advanced Micrologic X control units integrating current, voltage, power and energy metering, enabling earth leakage protection, and customizable with digital modules for advanced protection, measurement, energy management and network analysis functions
-  Built-in Class 1 accuracy active power and energy measurement
-  Switch disconnectors version available
-  Optimized range of field
- installable auxiliaries and accessories
-  Different offers complying with international standards :  IEC 60947, UL489, ANSI/UL1066
-  CCC, EAC and other local certifications
-  Compliance with specifications of marine classification companies :  Bureau Veritas, Lloyd’s Register of Shipping, Det Norske Veritas, etc.
- Range Benefits : Masterpact MTZ circuit breakers are Future Ready and contribute to power uptime and energy efficiency of your electrical installation thanks to : Optimized safety
-  Faultless protection
-  Complete selectivity and coordination (Type 1 & 2)
-  High resistance to environmental stressesIntegrated monitoring for energy efficiency
-  Improved uptime with complete monitoring solution in Smart Panels
-  Improved operation and maintenance using your smartphone with the Masterpact MTZ app
-  Advanced Micrologic X control unit can assist in providing corrective, preventive and predictive maintenance and energy management to identify potential savings
-  Seamless integration enabling users access to circuit breakers data in real time with a mobile device or a PC
-  Local and remote communication with trip cause (earth leakage, overload, short-circuit) and alarms (earth leakage, overload) allowing proactive operational and energy efficiencySeamless installation and retrofit
-  Wide range of online and offline software tools that improve productivity at all stages of your project (Ecoreal, Ecodial, MyPact, Ecoreach)
-  Additional digital modules available 24/7 on GoDigital – Schneider Electric e-commerce platform, offering advanced protection, measurement, energy management and network analysis functions
-  Seamless retrofit thanks to identical sizes, power connections and thermal properties as for the Masterpact NW and NT ranges
-  Standardized range of auxiliaries and accessoriesMasterpact MTZ is a part of EcoStruxureTM Power – Schneider Electric’s open, interoperable, IoT-enabled system architecture.
- Range Application Presentation : General applications in all types of low voltage electrical installationsSuitable in most applications for the protection, measurement, monitoring and quality of energy of LV electrical networks.This includes generator protection and motor protection, in standard applications and heavy
- duty applications demanding high performance, and ideal for : 
-  Industry :  mining operations, minerals, metals, and cement production, water & wastewater industry, automotive, food and beverage, etc.
-  Oil & Gas extraction and processing, Chemicals industries
-  Data centers
-  Healthcare infrastructure, hospitals
-  Marine and offshore industry
-  Infrastructures including airports, railways, subways, tunnels, power plants, etc.
-  Buildings :  commercial buildings, hotels, offices
-  Wind turbines, solar, gensetsSpecial applications
-  Source-changeover systems (Transferpact) :  service sector (hospital operating rooms, computer rooms, etc.), industry (assembly lines, ship engine rooms, etc.), infrastructures (runway, railway, etc.)

This product is under Green Premium products which is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations, transparency on environmental impacts, as well as circular and low-CO2 products
MAIN SPECIFICATIONS
Control Type3P
4P
Display TypeLCD display - 128 x 96 pixels
Measurement Accuracyactive energy Ep IN/OUT/tot: +/- 1 % - 10...10 GWh
active power P, P1, P2, P3, Pdemand: +/- 1 %
apparent energy Es IN/OUT/tot: +/- 1 % - 10...10 GVAh
apparent power S, S1, S2, S3, Sdemand: +/- 1 %
current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A
current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A
current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A
frequency: +/- 0.005 Hz
power factor: +/- 1 %
reactive energy Ep IN/OUT/tot: +/- 2 % - 10...10 GVARh
reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 %
unbalance current: +/- 0.5 %
voltage V21, V32, V13, VLLavg: +/- 0.5 % 208...690 x 1.2 V
voltage V21, V32, V13, VLNavg: +/- 0.5 % 120...400 x 1.2 V
Product Or Component Typecontrol unit
[Ue] Rated Operational Voltage690 V AC, +/- 10 %
Circuit Breaker Applicationdistribution IEC standard
Communication Port ProtocolBluetooth 4.0 LE peer to peer 30 kbit/s
NFC peer to peer conforming to ISO 15963
USB peer to peer 115 kbauds
Device Short NameMicrologic 5.0 X
EAN133606480811258
Energy Managementmeasurement ,active, reactive and apparent energy (standard)
measurement ,electrical network (standard)
measurement ,energy (standard)
Network TypeAC
Protected Poles Description3P 3d
4P 3d
4P 3d + N/2
4P 3d + OSN
4P 4d
RangeMasterpact
Range Compatibility Masterpact MTZ1 circuit breaker
Range NameMasterpact MTZ
Trip Unit Protection FunctionsLSI
Trip Unit Technologyelectronic
Type Of Measurementpower meter
COMPLEMENTARY
Analogue Output NumberLCD display - 128 x 96 pixels
Communication Network Type690 V AC, +/- 10 %
Time Delayactive energy Ep IN/OUT/tot: +/- 1 % - 10...10 GWh
active power P, P1, P2, P3, Pdemand: +/- 1 %
apparent energy Es IN/OUT/tot: +/- 1 % - 10...10 GVAh
apparent power S, S1, S2, S3, Sdemand: +/- 1 %
current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A
current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A
current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A
frequency: +/- 0.005 Hz
power factor: +/- 1 %
reactive energy Ep IN/OUT/tot: +/- 2 % - 10...10 GVARh
reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 %
unbalance current: +/- 0.5 %
voltage V21, V32, V13, VLLavg: +/- 0.5 % 208...690 x 1.2 V
voltage V21, V32, V13, VLNavg: +/- 0.5 % 120...400 x 1.2 V
Accuracy Classclass 0.5: unbalance voltage
class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h)
class 2: total voltage harmonic distortion THD (V)
class 5: total current harmonic distortion THD (I)
Data Recordingalarm logs
data logs
event logs
maintenance logs
min/max of instantaneous values
time stamping
Device Applicationequipment protection, monitoring and control
Frequency Measurement Range45-250 Hz
Instantaneous Pick-up Adjustment Range2...15 x In adjustable in step of 0.1 x In with Ecoreach software or Masterpact MTZ mobile app
2...15 x In adjustable in step of 0.5 x In with embedded HMI
Ii enable on/off
Instantaneous Pick-up Adjustment Type Iiadjustable
Long Time Delay Adjustment Typeadjustable in step of 0.5 s
Long Time Pick-up Adjustment Range0.4...1 x In adjustable in step of 1 A
Measurement Voltage145.6-828 V AC 50/60 Hz per phase
Metering Typeactive power P, P1, P2, P3 standard)
apparent power S, S1, S2, S3 standard)
average voltage Vavg standard)
current I1, I2, I3, In, Ig: maximum standard)
demand current I1, I2, I3, In, Iavg standard)
demand power P, Q, S standard)
frequency standard)
power factor standard)
reactive power Q, Q1, Q2, Q3 standard)
total current harmonic distortion THD (I): inst, avg, avg min, avg max fundamental voltage standard)
total current harmonic distortion THD (I): inst, avg, avg min, avg max RMS voltage standard)
total voltage harmonic distortion THD (V): inst, avg, avg min, avg max fundamental voltage standard)
total voltage harmonic distortion THD (V): inst, avg, avg min, avg max RMS voltage standard)
voltage V21, V32, V13, V1, V2, V3: instantaneous standard)
voltage V21, V32, V13, V1, V2, V3: maximum standard)
voltage V21, V32, V13, V1, V2, V3: minimum standard)
Mounting Locationindoor use only
Mounting Modedrawout
Network And Machine Diagnosis Typebreaker service life: circuit breaker health state standard)
configured alarms synthesis: diagnostic data standard)
contacts state: circuit breaker health state standard)
identification card: diagnostic data standard)
micrologic service life: circuit breaker health state standard)
micrologic test: test standard)
monitored function: diagnostic data standard)
operation: advanced diagnostic standard)
operation: diagnostic data standard)
protection test: test standard)
selectivity test: test standard)
system (HMI) health state overview: circuit breaker health state standard)
trip context information: crisis management standard)
tripping cause indication: circuit breaker tripping cause standard)
Network Frequency50/60 Hz
Operating Time0 ms in fast
20 ms in standard
Protection Typeinstantaneous short-circuit protection conforming to ANSI 50
overload (long time) conforming to ANSI 49
short time short-circuit protection conforming to ANSI 51
Short-time Delay Adjustment Typeadjustable
Thermal Memoryyes
Trip Unit Rating1000-1000 A
1250-1250 A
1600-1600 A
2000-2000 A
2500-2500 A
3200-3200 A
4000-4000 A
400-400 A
5000-5000 A
6300-6300 A
630-630 A
800-800 A
Zone Selective Interlocking ZSIwith
[Isd] Short-time Pick-up Adjustment Range1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or Masterpact MTZ mobile app
1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI
[tr] Long-time Delay Adjustment Range0.5-24 s at 6 x Ir
0.7-16.6 s at 7.2 x Ir
12.5-600 s at 1.5 x Ir
[tsd] Short-time Delay Adjustment Range0.1-0.4 s I²t=on
0-0.4 s I²t=off
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C (operating)
-35--35 °C (for start-up of product)
Electromagnetic Compatibility1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5
conducted and radiated emissions A conforming to CISPR 22
conducted RF disturbances conforming to IEC 61000-4-6
electrical fast transient/burst immunity test conforming to IEC 61000-4-4
electrostatic discharge immunity test conforming to IEC 61000-4-2
susceptibility to electromagnetic fields conforming to IEC 61000-4-3
Environmental Characteristicwet location not approved for use conforming to IEC 61010-1
Measurement Categorycategory IV conforming to IEC 61010-2-30
Operating Altitude<= 2000 m without derating
<= 4000 m with operational voltage derating 600 V AC
<= 5000 m with operational voltage derating 560 V AC
Overvoltage CategoryIV conforming to IEC 61010-1
Pollution Degree3 conforming to IEC 60947-1
Relative Humidity95-95 % at 55-55 °C conforming to IEC 60068-2-30
StandardsEN/IEC 60092-202
EN/IEC 60255-1
EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 61010-1
OTHER
Poles Description3P
4P