Loading...
*All information are subjected to changes without prior notice.

LV433581 - Circuit Breaker Compact NSX250HB2 - Micrologic 5.2 E - 160 A - 4 Poles 4d

Schneider
SKU
SE_LV433581
Model
LV433581

Obsolete

All prices inclusive of GST

Short description of LV433581

LV433581. NSX250HB2 CIRCUIT BREAKER 5.2 E 160A 4P
Obsolete
circuit breaker Compact NSX250HB2
-  Micrologic 5.2 E
-  160 A
-  4 poles 4d.
Label : Compact NSX
- range : Compact
- network type : AC
- network frequency : 50/60 Hz
- [In] rated current : 
- [Ui] rated insulation voltage : 
- range of product : NSX100...250-[Uimp] rated impulse withstand voltage : 
- [Ue] rated operational voltage : 
- Breaking capacity code : 
- breaking capacity : 
- [Ics] rated service breaking capacity : 
- suitability for isolation : 
- utilisation category : category A
- product name : Compact NSX
- product or component type : circuit breaker
- trip unit name : Micrologic 5.2 E
- trip unit technology : electronic
- trip unit protection functions : LSI
- device short name : Compact NSX250HB2-device application : distribution-poles description : 4P
- protected poles description : 3t + OSN,3t,4t,3t + N/2-pollution degree : 
- neutral position : left
- Range Presentation : The Compact NSX molded case circuit breaker (MCCB) range is designed to optimize space and breaking capacity. The range comes in two frame sizes with a variety of optional functions and accessories.
Specifications : 
-  Flexible installation :  any position; switchboard or wall
- mounted
-  Nominal current :  16 to 630 A
-  9 Breaking capacities for the 2 sizes of circuit breakers : 
-  up to 250 A :  25, 36, 50, 70, 100, 150, 200 kA at 415 V
-  up to 630 A :  36, 50, 70, 100, 150, 200 kA at 415 V
-  both size of circuit breakers with 75 & 100 kA at 690 V
-  1, 2, 3 and 4 pole versions available
-  Large range of electronic and thermal
- magnetic protections
-  Advanced trip unit with integrated power metering :  I, U, P, E, THD, f, CosPhi
-  Interchangeable trip
- units to upgrade your panel with smarter functions
-  Plug and ready wiring system and communicating accessories
-  Wealth of options for auxiliaries and accessories (field installable)
-  Integrated earth leakage protection via Micrologic Vigi coming soon in Q4 2018 (earth leakage circuit breaker
-  ELCB)For more information, download the Compact NSX & NSXm catalog
Visit the Schneider Electric Electrical Calculation Tools to review, search and check curves, selectivity and cascading. Alternatively, download the Complimentary Technical Information catalog (PDF), which includes coordination tables.
- Range Benefits : Easy and efficient
-  Two standardized frame sizes for your convenience
-  Save space, time and effort with integrated earth leakage protection (ELCB), available in Q4 2018, in the molded case circuit breaker (MCCB) frame size
-  Easy to swap trip units and standardized accessories over time
-  Wide range of online and offline software tools that help to improve productivity at all stages of your project (Ecoreal, Ecodial, MyPact, Ecoreach)Optimize safety
-  Highly resistant to environmental stresses
-  Roto
- active breaking technology helps to reduce early aging effects and increase operation lifespanMeasure and Communicate
-  Local and remote communication with trip alarm (earth leakage, overload, short circuit) and pre- alarms (earth leakage) allowing you to proactively increase operational and energy efficiency
-  Advanced Micrologic trip unit can assist in providing corrective, preventative and predictive maintenance and energy management to identify potential savingsWorking with communication devices, the Compact NSX inside our Smart Panels becomes an EcoStruxure connected product within our EcoStruxure Power architecture.
Click to watch the video and discover more about Compact NSX & NSXm molded case circuit breakers.
- Range Application Presentation : An excellent choice for all standard and specific applications, including : 
-  Standard applications :  industries, buildings, infrastructures
-  Specific applications demanding high performance :  marine, oil and gas extraction and processing, mining operations, metals and minerals production, and data centers
-  Source-changeover systems (Transferpact) :  service sector (hospital operating rooms, computer rooms, ), industry (assembly lines, ship engine rooms, etc.), infrastructures (runway, railway, etc.) Ensures compliance with international standards (Find on Compact NSX certificate downloads) : 
-  IEC/EN 60947-1 and 2, IEC 60068-2-30 for type 2 tropicalisation, CCC, EAC and other local certifications
-  Compliance with specifications of marine classification companies :  Bureau Veritas, Lloyd’s Register of Shipping, DetNorske Veritas and RINA
MAIN SPECIFICATIONS
Breaking Capacity100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking Capacity CodeHB2 100 kA 690 V AC
Contacts Type And Composition160 A at 40 °C
Control Typetoggle
Display TypeLCD display
Product Or Component Typecircuit breaker
Range Of ProductComPact NSX100...250
Trip Unit NameMicrologic 5.2 E
[Ie] Rated Operational Currenttoggle
[Ue] Rated Operational Voltage690 V AC 50/60 Hz
Device Short NameNSX250HB2
EAN133606480480669
Mounting Supportbackplate
Network TypeAC
Neutral Positionleft
Protected Poles Description3t
3t + N/2
3t + OSN
4t
RangeComPact
Range NameComPact NSX
Suitability For Isolationyes conforming to EN/IEC 60947-2
Trip Unit Protection FunctionsLSI
Trip Unit Technologyelectronic
Type Of Measurementenergy meter
Utilisation Categorycategory A
COMPLEMENTARY
Analogue Output NumberLCD display
Communication Network Type690 V AC 50/60 Hz
Current Transformer TypeHB2 100 kA 690 V AC
Interlocked Device100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Product NameComPact NSX
[Ics] Rated Service Breaking Capacity100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
100 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[In] Rated Current160 A at 40 °C
Communication Of Datademand current and power
energy metering
instantaneous and demand values
maintenance indicators
maximeters/minimeters
power quality
protection and alarm settings
time-stamped histories and event tables
Compatibility CodeNSX250
Connection Pitch35 mm
Depth86 mm
Device Applicationdistribution
Downside Connectionfront
Earth-leakage Protectionwithout
Electrical Durability10000 cycles at 440 V In
10000 cycles at 690 V In/2
20000 cycles at 440 V In/2
5000 cycles at 690 V In
Height161 mm
Instantaneous Pick-up Adjustment Range1.5...15 x In
Instantaneous Pick-up Adjustment Type Iiadjustable
Local Signallingflashing LED (green) for ready to operate
LED 105 % Ir (red) for overload
LED 90 % Ir (orange) for overload
Long Time Delay Adjustment Typeadjustable
Long Time Pick-up Adjustment Range63...160 A
Long Time Pick-up Adjustment Type Iradjustable 9 settings
Mechanical Durability20000 cycles
Mounting Modefixed
Net Weight2.8 kg
Network Frequency50/60 Hz
Neutral Protection Setting0.5 x Ir (3t + N/2)
1 x Ir (4t)
1.6 x Ir (3t + OSN)
no protection (3t)
Number Of Slots5 slot(s)
Protection TypeI : for instantaneous short-circuit protection
L : for overload protection (long time)
S : for short time short-circuit protection
Short-time Delay Adjustment Typeadjustable
Short-time Pick-up Adjustment Type Isdadjustable 9 settings
Thermal Memory20 minutes before and after tripping
Trip Unit Rating160-160 A at 40 °C
Upside Connectionfront
Width140 mm
Zone Selective Interlocking ZSIwith
[Isd] Short-time Pick-up Adjustment Range1.5...10 x Ir
[tr] Long-time Delay Adjustment Range0.35-11 s at 7.2 x Ir
0.5-16 s at 6 x Ir
15-400 s at 1.5 x Ir
[tsd] Short-time Delay Adjustment Range0-0.4 s
[Uimp] Rated Impulse Withstand Voltage8 kV
[Ui] Rated Insulation Voltage800 V AC 50/60 Hz
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-40-85 °C
Electrical Shock Protection Classclass II
IK Degree Of ProtectionIK07 conforming to IEC 62262
IP Degree Of ProtectionIP40 conforming to IEC 60529
Operating Altitude0...2000 m without derating
2000 m...5000 m with derating
Overvoltage Categoryclass II
Pollution Degree3 conforming to IEC 60664-1
Product CertificationsCCC
EAC
Marine
Relative Humidity0-95 %
StandardsEN/IEC 60947
OTHER
Earth Leakage CurrentMicrologic 5.2 E
Poles Description4P
[Us] Rated Supply VoltageComPact NSX100...250