LV433581 - Circuit Breaker Compact NSX250HB2 - Micrologic 5.2 E - 160 A - 4 Poles 4d
Schneider
SKU
SE_LV433581
Model
LV433581
Obsolete
Short description of LV433581
LV433581. NSX250HB2 CIRCUIT BREAKER 5.2 E 160A 4P
Obsolete
circuit breaker Compact NSX250HB2
-  Micrologic 5.2 E
-  160 A
-  4 poles 4d.
Label : Compact NSX
- range : Compact
- network type : AC
- network frequency : 50/60 Hz
- [In] rated current : 
- [Ui] rated insulation voltage : 
- range of product : NSX100...250-[Uimp] rated impulse withstand voltage : 
- [Ue] rated operational voltage : 
- Breaking capacity code : 
- breaking capacity : 
- [Ics] rated service breaking capacity : 
- suitability for isolation : 
- utilisation category : category A
- product name : Compact NSX
- product or component type : circuit breaker
- trip unit name : Micrologic 5.2 E
- trip unit technology : electronic
- trip unit protection functions : LSI
- device short name : Compact NSX250HB2-device application : distribution-poles description : 4P
- protected poles description : 3t + OSN,3t,4t,3t + N/2-pollution degree : 
- neutral position : left
- Range Presentation : The Compact NSX molded case circuit breaker (MCCB) range is designed to optimize space and breaking capacity. The range comes in two frame sizes with a variety of optional functions and accessories.
Specifications : 
-  Flexible installation :  any position; switchboard or wall
- mounted
-  Nominal current :  16 to 630 A
-  9 Breaking capacities for the 2 sizes of circuit breakers : 
-  up to 250 A :  25, 36, 50, 70, 100, 150, 200 kA at 415 V
-  up to 630 A :  36, 50, 70, 100, 150, 200 kA at 415 V
-  both size of circuit breakers with 75 & 100 kA at 690 V
-  1, 2, 3 and 4 pole versions available
-  Large range of electronic and thermal
- magnetic protections
-  Advanced trip unit with integrated power metering :  I, U, P, E, THD, f, CosPhi
-  Interchangeable trip
- units to upgrade your panel with smarter functions
-  Plug and ready wiring system and communicating accessories
-  Wealth of options for auxiliaries and accessories (field installable)
-  Integrated earth leakage protection via Micrologic Vigi coming soon in Q4 2018 (earth leakage circuit breaker
-  ELCB)For more information, download the Compact NSX & NSXm catalog
Visit the Schneider Electric Electrical Calculation Tools to review, search and check curves, selectivity and cascading. Alternatively, download the Complimentary Technical Information catalog (PDF), which includes coordination tables.
- Range Benefits : Easy and efficient
-  Two standardized frame sizes for your convenience
-  Save space, time and effort with integrated earth leakage protection (ELCB), available in Q4 2018, in the molded case circuit breaker (MCCB) frame size
-  Easy to swap trip units and standardized accessories over time
-  Wide range of online and offline software tools that help to improve productivity at all stages of your project (Ecoreal, Ecodial, MyPact, Ecoreach)Optimize safety
-  Highly resistant to environmental stresses
-  Roto
- active breaking technology helps to reduce early aging effects and increase operation lifespanMeasure and Communicate
-  Local and remote communication with trip alarm (earth leakage, overload, short circuit) and pre- alarms (earth leakage) allowing you to proactively increase operational and energy efficiency
-  Advanced Micrologic trip unit can assist in providing corrective, preventative and predictive maintenance and energy management to identify potential savingsWorking with communication devices, the Compact NSX inside our Smart Panels becomes an EcoStruxure connected product within our EcoStruxure Power architecture.
Click to watch the video and discover more about Compact NSX & NSXm molded case circuit breakers.
- Range Application Presentation : An excellent choice for all standard and specific applications, including : 
-  Standard applications :  industries, buildings, infrastructures
-  Specific applications demanding high performance :  marine, oil and gas extraction and processing, mining operations, metals and minerals production, and data centers
-  Source-changeover systems (Transferpact) :  service sector (hospital operating rooms, computer rooms, ), industry (assembly lines, ship engine rooms, etc.), infrastructures (runway, railway, etc.) Ensures compliance with international standards (Find on Compact NSX certificate downloads) : 
-  IEC/EN 60947-1 and 2, IEC 60068-2-30 for type 2 tropicalisation, CCC, EAC and other local certifications
-  Compliance with specifications of marine classification companies :  Bureau Veritas, Lloyd’s Register of Shipping, DetNorske Veritas and RINA
-  Micrologic 5.2 E
-  160 A
-  4 poles 4d.
Label : Compact NSX
- range : Compact
- network type : AC
- network frequency : 50/60 Hz
- [In] rated current : 
- [Ui] rated insulation voltage : 
- range of product : NSX100...250-[Uimp] rated impulse withstand voltage : 
- [Ue] rated operational voltage : 
- Breaking capacity code : 
- breaking capacity : 
- [Ics] rated service breaking capacity : 
- suitability for isolation : 
- utilisation category : category A
- product name : Compact NSX
- product or component type : circuit breaker
- trip unit name : Micrologic 5.2 E
- trip unit technology : electronic
- trip unit protection functions : LSI
- device short name : Compact NSX250HB2-device application : distribution-poles description : 4P
- protected poles description : 3t + OSN,3t,4t,3t + N/2-pollution degree : 
- neutral position : left
- Range Presentation : The Compact NSX molded case circuit breaker (MCCB) range is designed to optimize space and breaking capacity. The range comes in two frame sizes with a variety of optional functions and accessories.
Specifications : 
-  Flexible installation :  any position; switchboard or wall
- mounted
-  Nominal current :  16 to 630 A
-  9 Breaking capacities for the 2 sizes of circuit breakers : 
-  up to 250 A :  25, 36, 50, 70, 100, 150, 200 kA at 415 V
-  up to 630 A :  36, 50, 70, 100, 150, 200 kA at 415 V
-  both size of circuit breakers with 75 & 100 kA at 690 V
-  1, 2, 3 and 4 pole versions available
-  Large range of electronic and thermal
- magnetic protections
-  Advanced trip unit with integrated power metering :  I, U, P, E, THD, f, CosPhi
-  Interchangeable trip
- units to upgrade your panel with smarter functions
-  Plug and ready wiring system and communicating accessories
-  Wealth of options for auxiliaries and accessories (field installable)
-  Integrated earth leakage protection via Micrologic Vigi coming soon in Q4 2018 (earth leakage circuit breaker
-  ELCB)For more information, download the Compact NSX & NSXm catalog
Visit the Schneider Electric Electrical Calculation Tools to review, search and check curves, selectivity and cascading. Alternatively, download the Complimentary Technical Information catalog (PDF), which includes coordination tables.
- Range Benefits : Easy and efficient
-  Two standardized frame sizes for your convenience
-  Save space, time and effort with integrated earth leakage protection (ELCB), available in Q4 2018, in the molded case circuit breaker (MCCB) frame size
-  Easy to swap trip units and standardized accessories over time
-  Wide range of online and offline software tools that help to improve productivity at all stages of your project (Ecoreal, Ecodial, MyPact, Ecoreach)Optimize safety
-  Highly resistant to environmental stresses
-  Roto
- active breaking technology helps to reduce early aging effects and increase operation lifespanMeasure and Communicate
-  Local and remote communication with trip alarm (earth leakage, overload, short circuit) and pre- alarms (earth leakage) allowing you to proactively increase operational and energy efficiency
-  Advanced Micrologic trip unit can assist in providing corrective, preventative and predictive maintenance and energy management to identify potential savingsWorking with communication devices, the Compact NSX inside our Smart Panels becomes an EcoStruxure connected product within our EcoStruxure Power architecture.
Click to watch the video and discover more about Compact NSX & NSXm molded case circuit breakers.
- Range Application Presentation : An excellent choice for all standard and specific applications, including : 
-  Standard applications :  industries, buildings, infrastructures
-  Specific applications demanding high performance :  marine, oil and gas extraction and processing, mining operations, metals and minerals production, and data centers
-  Source-changeover systems (Transferpact) :  service sector (hospital operating rooms, computer rooms, ), industry (assembly lines, ship engine rooms, etc.), infrastructures (runway, railway, etc.) Ensures compliance with international standards (Find on Compact NSX certificate downloads) : 
-  IEC/EN 60947-1 and 2, IEC 60068-2-30 for type 2 tropicalisation, CCC, EAC and other local certifications
-  Compliance with specifications of marine classification companies :  Bureau Veritas, Lloyd’s Register of Shipping, DetNorske Veritas and RINA
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity | 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
Breaking Capacity Code | HB2 100 kA 690 V AC |
Contacts Type And Composition | 160 A at 40 °C |
Control Type | toggle |
Display Type | LCD display |
Product Or Component Type | circuit breaker |
Range Of Product | ComPact NSX100...250 |
Trip Unit Name | Micrologic 5.2 E |
[Ie] Rated Operational Current | toggle |
[Ue] Rated Operational Voltage | 690 V AC 50/60 Hz |
Device Short Name | NSX250HB2 |
EAN13 | 3606480480669 |
Mounting Support | backplate |
Network Type | AC |
Neutral Position | left |
Protected Poles Description | 3t 3t + N/2 3t + OSN 4t |
Range | ComPact |
Range Name | ComPact NSX |
Suitability For Isolation | yes conforming to EN/IEC 60947-2 |
Trip Unit Protection Functions | LSI |
Trip Unit Technology | electronic |
Type Of Measurement | energy meter |
Utilisation Category | category A |
COMPLEMENTARY | |
Analogue Output Number | LCD display |
Communication Network Type | 690 V AC 50/60 Hz |
Current Transformer Type | HB2 100 kA 690 V AC |
Interlocked Device | 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
Product Name | ComPact NSX |
[Ics] Rated Service Breaking Capacity | 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 100 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
[In] Rated Current | 160 A at 40 °C |
Communication Of Data | demand current and power energy metering instantaneous and demand values maintenance indicators maximeters/minimeters power quality protection and alarm settings time-stamped histories and event tables |
Compatibility Code | NSX250 |
Connection Pitch | 35 mm |
Depth | 86 mm |
Device Application | distribution |
Downside Connection | front |
Earth-leakage Protection | without |
Electrical Durability | 10000 cycles at 440 V In 10000 cycles at 690 V In/2 20000 cycles at 440 V In/2 5000 cycles at 690 V In |
Height | 161 mm |
Instantaneous Pick-up Adjustment Range | 1.5...15 x In |
Instantaneous Pick-up Adjustment Type Ii | adjustable |
Local Signalling | flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
Long Time Delay Adjustment Type | adjustable |
Long Time Pick-up Adjustment Range | 63...160 A |
Long Time Pick-up Adjustment Type Ir | adjustable 9 settings |
Mechanical Durability | 20000 cycles |
Mounting Mode | fixed |
Net Weight | 2.8 kg |
Network Frequency | 50/60 Hz |
Neutral Protection Setting | 0.5 x Ir (3t + N/2) 1 x Ir (4t) 1.6 x Ir (3t + OSN) no protection (3t) |
Number Of Slots | 5 slot(s) |
Protection Type | I : for instantaneous short-circuit protection L : for overload protection (long time) S : for short time short-circuit protection |
Short-time Delay Adjustment Type | adjustable |
Short-time Pick-up Adjustment Type Isd | adjustable 9 settings |
Thermal Memory | 20 minutes before and after tripping |
Trip Unit Rating | 160-160 A at 40 °C |
Upside Connection | front |
Width | 140 mm |
Zone Selective Interlocking ZSI | with |
[Isd] Short-time Pick-up Adjustment Range | 1.5...10 x Ir |
[tr] Long-time Delay Adjustment Range | 0.35-11 s at 7.2 x Ir 0.5-16 s at 6 x Ir 15-400 s at 1.5 x Ir |
[tsd] Short-time Delay Adjustment Range | 0-0.4 s |
[Uimp] Rated Impulse Withstand Voltage | 8 kV |
[Ui] Rated Insulation Voltage | 800 V AC 50/60 Hz |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -40-85 °C |
Electrical Shock Protection Class | class II |
IK Degree Of Protection | IK07 conforming to IEC 62262 |
IP Degree Of Protection | IP40 conforming to IEC 60529 |
Operating Altitude | 0...2000 m without derating 2000 m...5000 m with derating |
Overvoltage Category | class II |
Pollution Degree | 3 conforming to IEC 60664-1 |
Product Certifications | CCC EAC Marine |
Relative Humidity | 0-95 % |
Standards | EN/IEC 60947 |
OTHER | |
Earth Leakage Current | Micrologic 5.2 E |
Poles Description | 4P |
[Us] Rated Supply Voltage | ComPact NSX100...250 |