LV432100 - Trip Unit - Micrologic 5.3 E - 400 A - 4 Poles 4d.
Schneider
SKU
SE_LV432100
Model
LV432100
Obsolete
Short description of LV432100
LV432100. Circuit-breakers, to protect lines carrying up to 630A
Obsolete
range : ComPact
-  range of product : ComPact NSX400...630
-  product or component type : Trip unit
-  trip unit name : Micrologic 5.3 E
-  trip unit technology : Electronic
-  range compatibility : ComPact NSX400ComPact NSX630
-  device application : Distribution
-  Number of poles : 4P
-  protected poles description : 3t + N/24t3t + OSN3t
-  neutral position : Left
-  trip unit protection functions : LSI
-  protection type : L  :  for overload protection (long time)S  :  for short time short-circuit protectionI  :  for instantaneous short-circuit protection
-  Trip unit rated current : 400 A at 40 °C
-  [Ue] rated operational voltage : 690 V AC 50/60 Hz
-  network type : AC
-  network frequency : 50/60 Hz
-  range of product : ComPact NSX400...630
-  product or component type : Trip unit
-  trip unit name : Micrologic 5.3 E
-  trip unit technology : Electronic
-  range compatibility : ComPact NSX400ComPact NSX630
-  device application : Distribution
-  Number of poles : 4P
-  protected poles description : 3t + N/24t3t + OSN3t
-  neutral position : Left
-  trip unit protection functions : LSI
-  protection type : L  :  for overload protection (long time)S  :  for short time short-circuit protectionI  :  for instantaneous short-circuit protection
-  Trip unit rated current : 400 A at 40 °C
-  [Ue] rated operational voltage : 690 V AC 50/60 Hz
-  network type : AC
-  network frequency : 50/60 Hz
MAIN SPECIFICATIONS | |
---|---|
Control Type | 4P |
Display Type | LCD display |
Product Or Component Type | trip unit |
Range Of Product | ComPact NSX400...630 |
Trip Unit Name | Micrologic 5.3 E |
[Ue] Rated Operational Voltage | 690 V AC 50/60 Hz |
Network Type | AC |
Neutral Position | left |
Protected Poles Description | 3t 3t + N/2 3t + OSN 4t |
Range | compact |
Range Compatibility | ComPact NSX400 ComPact NSX630 |
Range Name | ComPact NSX |
Trip Unit Protection Functions | LSI |
Trip Unit Technology | electronic |
Type Of Measurement | energy meter |
COMPLEMENTARY | |
Analogue Output Number | LCD display |
Communication Network Type | 690 V AC 50/60 Hz |
Product Name | Micrologic |
Communication Of Data | demand current and power energy metering instantaneous and demand values maintenance indicators maximeters/minimeters power quality protection and alarm settings time-stamped histories and event tables |
Device Application | distribution |
Earth-leakage Protection | without |
Electrical Data Recording | maintenance indicators |
Instantaneous Pick-up Adjustment Range | 1.5...12 x In |
Instantaneous Pick-up Adjustment Type Ii | adjustable |
Long Time Delay Adjustment Type | adjustable |
Long Time Pick-up Adjustment Range | 160...400 A |
Long Time Pick-up Adjustment Type Ir | adjustable 9 settings |
Network Frequency | 50/60 Hz |
Neutral Protection Setting | 0.5 x Ir (3t + N/2) 1 x Ir (4t) 1.6 x Ir (3t + OSN) no protection (3t) |
Protection Type | I : for instantaneous short-circuit protection L : for overload protection (long time) S : for short time short-circuit protection |
Short-time Delay Adjustment Type | adjustable |
Short-time Pick-up Adjustment Type Isd | adjustable 9 settings |
Thermal Memory | 20 minutes before and after tripping |
Zone Selective Interlocking ZSI | with |
[Isd] Short-time Pick-up Adjustment Range | 1.5...10 x Ir |
[tr] Long-time Delay Adjustment Range | 0.35-11 s at 7.2 x Ir 0.5-16 s at 6 x Ir 15-400 s at 1.5 x Ir |
[tsd] Short-time Delay Adjustment Range | 0.1-0.4 s I²t=on 0-0.4 s I²t=off |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -40-85 °C |
Product Certifications | CCC EAC Marine |
Standards | EN/IEC 60947-2 UL 508 |
OTHER | |
Earth Leakage Current | Micrologic 5.3 E |
Poles Description | 4P |
[Us] Rated Supply Voltage | ComPact NSX400...630 |