LV431520 - Trip Unit - Micrologic 2.2 M - 220 A - 3 Poles 3d.

Schneider
SKU
SE_LV431520
Model
LV431520

Obsolete

All prices inclusive of GST

Short description of LV431520

LV431520. Circuit-breakers, to protect lines carrying up to 630A
Obsolete
range : ComPact
-  range of product : ComPact NSX100...250
-  product or component type : Trip unit
-  trip unit name : Micrologic 2.2 M
-  trip unit technology : Electronic
-  range compatibility : ComPact NSX250
-  device application : Motor
-  Number of poles : 3P
-  protected poles description : 3t
-  trip unit protection functions : LSoI
-  protection type : L  :  for overload protection (long time)So  :  for short time short-circuit protection with fixed delayI  :  for instantaneous short-circuit protection
-  Trip unit rated current : 220 A at 65 °C
-  [Ue] rated operational voltage : 690 V AC 50/60 Hz
-  network type : AC
-  network frequency : 50/60 Hz
MAIN SPECIFICATIONS
Control Type3P
Product Or Component Typetrip unit
Range Of ProductComPact NSX100...250
Trip Unit NameMicrologic 2.2 M
[Ue] Rated Operational Voltage690 V AC 50/60 Hz
Motor Tripping Class10
20
5
Network TypeAC
Protected Poles Description3t
RangeComPact
Range CompatibilityComPact NSX250
Range NameComPact NSX
Trip Unit Protection FunctionsLSoI
Trip Unit Technologyelectronic
COMPLEMENTARY
Communication Network Type690 V AC 50/60 Hz
Product NameMicrologic
Complementary Motor Protectionphase unbalance
Device Applicationmotor
Earth-leakage Protectionwithout
Instantaneous Pick-up Adjustment Range3300 A
Instantaneous Pick-up Adjustment Type Iifixed
Long Time Delay Adjustment Typefixed
Long Time Pick-up Adjustment Range100...220 A
Long Time Pick-up Adjustment Type Iradjustable 9 settings
Network Frequency50/60 Hz
Protection TypeI : for instantaneous short-circuit protection
L : for overload protection (long time)
So : for short time short-circuit protection with fixed delay
Short-time Delay Adjustment Typefixed
Short-time Pick-up Adjustment Type Isdadjustable 9 settings
Thermal Memory20 minutes before and after tripping
Zone Selective Interlocking ZSIwithout
[Isd] Short-time Pick-up Adjustment Range5...13 x Ir
[tr] Long-time Delay Adjustment Range10-10 s at 7.2 x Ir for trip class 10
120-120 s at 1.5 x Ir for trip class 5
13.5-13.5 s at 6 x Ir for trip class 10
20-20 s at 7.2 x Ir for trip class 20
240-240 s at 1.5 x Ir for trip class 10
26-26 s at 6 x Ir for trip class 20
480-480 s at 1.5 x Ir for trip class 20
5-5 s at 7.2 x Ir for trip class 5
6.5-6.5 s at 6 x Ir for trip class 5
[tsd] Short-time Delay Adjustment Range0.01-0.01 s
ENVIRONMENT
Ambient Air Temperature For Operation-25-70 °C
Ambient Air Temperature For Storage-50-85 °C
Product CertificationsCCC
EAC
Marine
StandardsEN/IEC 60947-2
UL 508
OTHER
Earth Leakage CurrentMicrologic 2.2 M
Poles Description3P
[Us] Rated Supply VoltageComPact NSX100...250