LU2B32BL - Reversing Power Base, TeSys U, 3P, 32A/690V, Coil 24V DC.
Schneider
SKU
SE_LU2B32BL
Model
LU2B32BL
SGD $1,184.08 All prices inclusive of GST
Short description of LU2B32BL
LU2B32BL. All-in-one motor starters up to 38 A (18.5 kW / 400 V)
Country of Origin
France
range : TeSys
-  product name : TeSys U
-  device short name : LU2B
-  product or component type : Reversing power base
-  device application : Motor controlMotor protection
-  product compatibility : Control unit LUC.X6BLControl unit LUC.1XBLControl unit LUC.05BLControl unit LUC.12BLControl unit LUC.18BLControl unit LUC.32BL
-  poles description : 3P
-  suitability for isolation : Yes
-  [Ue] rated operational voltage : 690 V AC for power circuit
-  network frequency : 40...60 Hz
-  [Ith] conventional free air thermal current : 32 A
-  [Ie] rated operational current : 28.5 A at - utilisation category : AC
- 43AC
- 44AC
- 41
-  [Ics] rated service breaking capacity : 50 kA at 230 V50 kA at 440 V10 kA at 500 V4 kA at 690 V
-  auxiliary contact composition : 1 NO + 1 NC
-  auxiliary contacts type : type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1
-  [Uc] control circuit voltage : 24 V DC
-  control circuit voltage limits : 14.5 V DC drop
- out20...27 V DC in operation
-  product name : TeSys U
-  device short name : LU2B
-  product or component type : Reversing power base
-  device application : Motor controlMotor protection
-  product compatibility : Control unit LUC.X6BLControl unit LUC.1XBLControl unit LUC.05BLControl unit LUC.12BLControl unit LUC.18BLControl unit LUC.32BL
-  poles description : 3P
-  suitability for isolation : Yes
-  [Ue] rated operational voltage : 690 V AC for power circuit
-  network frequency : 40...60 Hz
-  [Ith] conventional free air thermal current : 32 A
-  [Ie] rated operational current : 28.5 A at - utilisation category : AC
- 43AC
- 44AC
- 41
-  [Ics] rated service breaking capacity : 50 kA at 230 V50 kA at 440 V10 kA at 500 V4 kA at 690 V
-  auxiliary contact composition : 1 NO + 1 NC
-  auxiliary contacts type : type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1
-  [Uc] control circuit voltage : 24 V DC
-  control circuit voltage limits : 14.5 V DC drop
- out20...27 V DC in operation
MAIN SPECIFICATIONS | |
---|---|
Breaking Capacity Code | 10 kA at 500 V 4 kA at 690 V 50 kA at 230 V 50 kA at 440 V |
Control Type | 3P |
Product Or Component Type | reversing power base |
Range Of Product | TeSys U |
[Ie] Rated Operational Current | 21 A at 690 V 23 A at 500 V 28.5 A at <= 440 V |
[Uc] Control Circuit Voltage | 24 V DC |
[Ue] Rated Operational Voltage | 690 V AC for power circuit |
Device Short Name | LU2B |
Range | TeSys |
Range Name | TeSys U |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
Suitability For Isolation | yes |
Utilisation Category | AC-41 AC-43 AC-44 |
COMPLEMENTARY | |
Communication Network Type | 690 V AC for power circuit |
Product Name | TeSys U |
[Ics] Rated Service Breaking Capacity | 10 kA at 500 V 4 kA at 690 V 50 kA at 230 V 50 kA at 440 V |
Auxiliary Contact Composition | 1 NO + 1 NC |
Auxiliary Contacts Type | type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1 type mirror contact (1 NC) conforming to IEC 60947-1 |
Compatibility Code | LU2B |
Connections - Terminals | control circuit: screw clamp terminals 1 cable(s) 0.34-1.5 mm² flexible with cable end control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² flexible without cable end control circuit: screw clamp terminals 1 cable(s) 0.75-1.5 mm² rigid control circuit: screw clamp terminals 2 cable(s) 0.34-1.5 mm² flexible with cable end control circuit: screw clamp terminals 2 cable(s) 0.75-1.5 mm² flexible without cable end control circuit: screw clamp terminals 2 cable(s) 0.75-1.5 mm² rigid power circuit: screw clamp terminals 1 cable(s) 1-10 mm² rigid power circuit: screw clamp terminals 1 cable(s) 1-6 mm² flexible with cable end power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm² flexible without cable end power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end power circuit: screw clamp terminals 2 cable(s) 1-6 mm² flexible with cable end power circuit: screw clamp terminals 2 cable(s) 1-6 mm² rigid |
Control Circuit Voltage Limits | 14.5 V DC drop-out 20...27 V DC in operation |
Depth | 126 mm |
Device Application | motor control motor protection |
Fixing Mode | clipped (DIN rail) screw-fixed (plate) |
Height | 224 mm |
Immunity To Microbreaks | 3 ms for control circuit |
Inrush Restraint Duration | 15 ms DC |
Maximum Operating Rate | 3600 cyc/h |
Mechanical Durability | 15 Mcycles |
Net Weight | 1.27 kg |
Network Frequency | 40...60 Hz |
Operating Time | 150 ms with change of direction for power circuit 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit 70 ms closing with LUCA, LUCB, LUCC, LUCD for control circuit 75 ms closing with LUCM for control circuit 75 ms without change of direction for power circuit |
Product Compatibility | control unit LUC.05BL control unit LUC.12BL control unit LUC.18BL control unit LUC.1XBL control unit LUC.32BL control unit LUC.X6BL |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N |
Tightening Torque | control circuit: 0.8-1.2 N.m flat screwdriver 5 mm control circuit: 0.8-1.2 N.m Philips no 1 screwdriver 5 mm power circuit: 1.9-2.5 N.m flat screwdriver 6 mm power circuit: 1.9-2.5 N.m Philips No 2 screwdriver 6 mm |
Typical Current Consumption | 120 mA at 24 V DC I maximum while closing 120 mA at 24 V DC I rms sealed |
Width | 45 mm |
[Ith] Conventional Free Air Thermal Current | 32 A |
[Uimp] Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947-6-2 |
[Ui] Rated Insulation Voltage | 600 V conforming to CSA C22.2 No 60947-4-1 600 V conforming to UL 60947-4-1 690 V conforming to IEC 60947-6-2 (pollution degree 3) |
ENVIRONMENT | |
Ambient Air Temperature For Operation | -25-60 °C with LUCM -25-70 °C with LUCA, LUCB, LUCC, LUCD |
Ambient Air Temperature For Storage | -40-85 °C |
Fire Resistance | 650 °C conforming to IEC 60695-2-12 960 °C parts supporting live components conforming to IEC 60695-2-12 |
Heat Dissipation | 1.8-1.8 W for control circuit with LUCM 3-3 W for control circuit with LUCA, LUCB, LUCC, LUCD |
Immunity To Radioelectric Fields | 10 V conforming to IEC 61000-4-6 |
Immunity To Voltage Dips | 70 % / 500 ms conforming to IEC 61000-4-11 |
IP Degree Of Protection | IP20 conforming to IEC 60947-1 (front panel and wired terminals) IP20 conforming to IEC 60947-1 (other faces) IP40 conforming to IEC 60947-1 (front panel outside connection zone) |
Operating Altitude | 2000 m |
Product Certifications | ASEFA ATEX CCC CE CSA EAC Marine UL |
Protective Treatment | TH conforming to IEC 60068 |
Resistance To Electrostatic Discharge | 8 kV level 3 in open air conforming to IEC 61000-4-2 8 kV level 4 on contact conforming to IEC 61000-4-2 |
Resistance To Fast Transients | 2 kV class 3 serial link conforming to IEC 61000-4-4 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
Resistance To Radiated Fields | 10 V/m 3 conforming to IEC 61000-4-3 |
Shock Resistance | 10 gn power poles open conforming to IEC 60068-2-27 15 gn power poles closed conforming to IEC 60068-2-27 |
Standards | CSA C22.2 No 60947-4-1, with phase barrier EN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier |
Vibration Resistance | 2 gn (f= 5-300 Hz) power poles open conforming to IEC 60068-2-27 4 gn (f= 5-300 Hz) power poles closed conforming to IEC 60068-2-27 |
OTHER | |
Poles Description | 3P |
[Us] Rated Supply Voltage | TeSys U |
Write Your Own Review