LP1SK0600BD - mini contactor, TeSys SK, 2P(2NO), AC-1, 690V 12A, 24V DC coil
Schneider
SKU
SE_LP1SK0600BD
Model
LP1SK0600BD
SGD $46.01 All prices inclusive of GST
Short description of LP1SK0600BD
LP1SK0600BD. Good adaptability: possible to insert contact block and suppressor module
High durability & stable performance: up to 1200 cycles/hour for operating rates
Reliable in high and low temperature environment
Modularity design and compact size for easy maintenance, save time and space on installation
Wide application with multi standards certifications
High durability & stable performance: up to 1200 cycles/hour for operating rates
Reliable in high and low temperature environment
Modularity design and compact size for easy maintenance, save time and space on installation
Wide application with multi standards certifications
Country of Origin
Czech Republic
TeSys SK mini-contactor, 2 poles (2NO), for non inductive load applications up to 12A/690V AC-1,
and for 1-phase motor control applications up to 6A/690V AC-3 (for 3-phase motors an add-on contact block LA1SK must be mounted on contactor).
It provides a 24V DC control circuit with no inrush consumption, connection by screw clamp terminals.
For operating rates until 1200 cycles/hour and ambient temperature -20/+50°C, it procures high reliability and durability.
Compact (27mm width), for clipping on a 35mm DIN rail.
Add-on contact blocks LA1SK (power pole, instantaneous auxiliary contacts) and suppressor modules LA4SK available (to be ordered separately).
Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium product (RoHS/REACh).
and for 1-phase motor control applications up to 6A/690V AC-3 (for 3-phase motors an add-on contact block LA1SK must be mounted on contactor).
It provides a 24V DC control circuit with no inrush consumption, connection by screw clamp terminals.
For operating rates until 1200 cycles/hour and ambient temperature -20/+50°C, it procures high reliability and durability.
Compact (27mm width), for clipping on a 35mm DIN rail.
Add-on contact blocks LA1SK (power pole, instantaneous auxiliary contacts) and suppressor modules LA4SK available (to be ordered separately).
Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium product (RoHS/REACh).
MAIN | |
---|---|
Product Or Component Type | Mini contactor |
Device Short Name | LP1SK |
Contactor Application | Resistive load |
Utilisation Category | AC-1 |
Power Pole Contact Composition | 2P |
Pole Contact Composition | 2 NO |
[Ue] Rated Operational Voltage | Power circuit: 690 V AC 50/60 Hz |
[Ie] Rated Operational Current | 12 A (at <55 °C) AC AC-1 |
Control Circuit Type | DC standard |
[Uc] Control Circuit Voltage | 24 V DC |
[Ith] Conventional Free Air Thermal Current | 12 A (at 55 °C) for power circuit |
Irms Rated Making Capacity | 66 A at 690 V AC conforming to IEC 60947 66 A at 690 V AC conforming to NF C 63-110 |
Rated Breaking Capacity | 52 A at <= 400 V for power circuit conforming to NF C 63-110 52 A at <= 400 V for power circuit conforming to IEC 60947 |
[Icw] Rated Short-time Withstand Current | 50 A 55 °C for power circuit |
Associated Fuse Rating | 16 A gI at <= 440 V for power circuit conforming to IEC 60947 |
Average Impedance | 4 mOhm - Ith 12 A 50 Hz |
[Ui] Rated Insulation Voltage | 690 V conforming to IEC 60947 690 V conforming to VDE 0110 group C 690 V conforming to BS 5424 690 V conforming to UL 508 690 V conforming to CSA C22.2 No 14 |
Mounting Support | Rail |
Standards | EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1 |
Product Certifications | CB Scheme CE UKCA EAC cULus |
Connections - Terminals | Power circuit: connector 1 cable(s) 0.35…6 mm²flexible with cable end Power circuit: connector 1 cable(s) 0.5…6 mm²flexible without cable end Power circuit: connector 1 cable(s) 1.5…6 mm²solid Power circuit: connector 2 cable(s) 0.35…1.5 mm²flexible with cable end Power circuit: connector 2 cable(s) 0.35…2.5 mm²flexible without cable end Power circuit: connector 2 cable(s) 1.5…4 mm²solid |
Tightening Torque | 0.8 N.m - on connector - with screwdriver pozidriv No 1 |
Operating Time | 4...6 ms coil de-energisation and NO opening 8...12 ms coil energisation and NO closing |
Mechanical Durability | 10 Mcycles |
Maximum Operating Rate | 1200 cyc/h |
COMPLEMENTARY | |
Control Circuit Voltage Limits | Operational: 0.85...1.1 Uc (at <50 °C) Drop-out: 0.1...0.75 Uc (at <50 °C) |
Inrush Power In W | 2.2 W (at 20 °C) |
Hold-in Power Consumption In W | 2.2 W at 20 °C |
Heat Dissipation | 2.2 W |
ENVIRONMENT | |
IP Degree Of Protection | IP2X conforming to VDE 0106 |
Protective Treatment | TC conforming to IEC 60068 TC conforming to DIN 50015 |
Ambient Air Temperature For Operation | -20…50 °C |
Ambient Air Temperature For Storage | -50…70 °C |
Operating Altitude | 2000 m without derating |
Height | 56 mm |
Width | 27 mm |
Depth | 55.5 mm |
Net Weight | 0.132 kg |
PACKING UNITS | |
Unit Type Of Package 1 | PCE |
Number Of Units In Package 1 | 1 |
Package 1 Height | 3.3 cm |
Package 1 Width | 5.9 cm |
Package 1 Length | 6.7 cm |
Package 1 Weight | 122.0 g |
Unit Type Of Package 2 | S01 |
Number Of Units In Package 2 | 40 |
Package 2 Height | 15.0 cm |
Package 2 Width | 15.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 5.174 kg |
CONTRACTUAL WARRANTY | |
Warranty | 18 months |
Write Your Own Review