LC1SKGC301P7 - Mini contactor, TeSys SK, 3P(3NO), AC-3, 690V 9A, 230V AC coil

Schneider
SKU
SE_LC1SKGC301P7
Model
LC1SKGC301P7
SGD $35.71 All prices inclusive of GST

Short description of LC1SKGC301P7

LC1SKGC301P7. It is desingned with transparent protective cover at front for double security
Good adaptability: possible to insert a suppressor module
High durability & stable performance: up to 1200 cycles/hour for operating rates
Reliable in high and low temperature environment
Modularity design and compact size for easy maintenance, save time and space on installation
-
+

UOM: Piece

In stock
In Stock 0
Backorder Leadtime: 13 To 15 Weeks

Certificate of Conformance (COC) can be provided upon purchase subjected to manufacturer approval.

TeSys SKGC mini-contactor, 3 poles (3NO), for non-inductive load applications up to 20A/690V AC-1,
and for 3-phase motor control applications up to 9A/690V AC-3 (4kW@400V).
It provides a 230V 50/60Hz AC control circuit, 1NC auxiliary contact, a transparent protective cover to prevent front face access, connection by screw terminals.
For operating rates until 1200 cycles/hour and ambient temperature -20/+50°C, it procures high reliability and durability.
For use in modular panels, compact (45mm width), clipping on 35mm DIN rail or fixing by 2 screws.
Location available to insert a suppressor module LA4SK (to be ordered separately).
Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).
MAIN
RangeTeSys
Product NameTeSys SK
Product Or Component TypeMini contactor
Device Short NameLC1SKGC
Contactor ApplicationResistive load
Motor control
Utilisation CategoryAC-3
AC-1
Power Pole Contact Composition3P
Pole Contact Composition3 NO
Auxiliary Contact Composition1 NC
[Ie] Rated Operational Current20 A (at <50 °C) AC AC-1
9 A at <= 400 V AC AC-3
[Ue] Rated Operational VoltagePower circuit: 690 V AC 50/60 Hz
Signalling circuit: 690 V AC <= 400 Hz
COMPLEMENTARY
Control Circuit TypeAC at 50/60 Hz
[Uc] Control Circuit Voltage230 V AC 50/60 Hz
Motor Power KW4 kW at 380...415 V AC 50/60 Hz
4 kW at 660...690 V AC 50/60 Hz
1.1 kW at 220...230 V AC 50/60 Hz
[Ith] Conventional Free Air Thermal Current20 A (at 55 °C) for power circuit
10 A (at 55 °C) for signalling circuit
Irms Rated Making Capacity85 A AC conforming to NF C 63-110
85 A AC conforming to IEC 60947
Rated Breaking Capacity68 A at <= 400 V conforming to NF C 63-110
68 A at <= 400 V conforming to IEC 60947
[Icw] Rated Short-time Withstand Current60 A 55 °C for power circuit
Associated Fuse Rating20 A gI at <= 440 V for power circuit
10 A gI for signalling circuit conforming to IEC 60947
10 A gI for signalling circuit conforming to VDE 0660
Average Impedance4 mOhm - Ith 20 A 50 Hz for power circuit
[Ui] Rated Insulation VoltagePower circuit: 690 V conforming to BS 5424
Power circuit: 690 V conforming to IEC 60947
Power circuit: 690 V conforming to UL 508
Power circuit: 690 V conforming to VDE 0110 group C
Power circuit: 690 V conforming to CSA C22.2 No 14
Mounting SupportPanel
Rail
StandardsEN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product CertificationsCB Scheme
CE
UKCA
EAC
cULus
Connections - TerminalsConnector 1 cable(s) 1.5…6 mm²solid
Connector 2 cable(s) 1.5…4 mm²solid
Connector 1 cable(s) 0.5…6 mm²flexible without cable end
Connector 2 cable(s) 0.35…2.5 mm²flexible without cable end
Connector 1 cable(s) 0.35…6 mm²flexible with cable end
Connector 2 cable(s) 0.35…1.5 mm²flexible with cable end
Tightening TorquePower circuit: 0.8 N.m - on connector - with screwdriver pozidriv No 1
Operating Time6...8 ms coil de-energisation and NO opening
7...14 ms coil energisation and NO closing
8...16 ms coil energisation and NC opening
8...10 ms coil de-energisation and NC closing
Mechanical Durability10 Mcycles
Maximum Operating Rate1200 cyc/h
Control Circuit Voltage LimitsOperational: 0.85...1.1 Uc at 50/60 Hz (at <55 °C)
Drop-out: 0.2...0.75 Uc at 50/60 Hz (at <55 °C)
Inrush Power In VA23 VA 50/60 Hz (at 20 °C)
Hold-in Power Consumption In VA4.9 VA 50/60 Hz (at 20 °C)
Heat Dissipation1.5 W at 50/60 Hz
Signalling Circuit Frequency<= 400 Hz
ENVIRONMENT
IP Degree Of ProtectionIP2X conforming to VDE 0106
Protective TreatmentTC conforming to IEC 60068
TC conforming to DIN 50015
Ambient Air Temperature For Operation-20…50 °C
Ambient Air Temperature For Storage-50…70 °C
Operating Altitude2000 m without derating
Height58 mm
Width45 mm
Depth56 mm
Net Weight0.175 kg
PACKING UNITS
Unit Type Of Package 1PCE
Number Of Units In Package 11
Package 1 Height4.800 cm
Package 1 Width6.200 cm
Package 1 Length6.000 cm
Package 1 Weight167.000 g
Unit Type Of Package 2S01
Number Of Units In Package 228
Package 2 Height15.000 cm
Package 2 Width15.000 cm
Package 2 Length40.000 cm
Package 2 Weight4.862 kg
CONTRACTUAL WARRANTY
Warranty18 months